concentric cable
Overhead
Low Voltage
AC Cable
XLPE
PVC
Flat Wire
Aluminum or Copper
ISO
Concentric
Zoom Link
AA8000, 1350 Al, Copper
XLPE or PVC
XLPE or PVC
8AWG to 4/0 AWG
2
Manufacture
5000m
100% Test Each Drum
Factory Prices
ZML
Drum
10AWG to 4/0 AWG
China
8544492100
Product Description
Cobre concentrico de cable and concentric cable 2x4mm, 2x6mm ,2x10mm,

1. STANDARD
The concentric conductors of copper and aluminum, is entirely consistent with the rules ASTM D 790, D 1248, D 2655, D 2656, UL 854, UL 44, .
2. CHARACTERISTICS OF THE COPPER AND ALUMINUM CONDUCTORS
The concentric conductors of copper and aluminum, is entirely consistent with the rules ASTM D 790, D 1248, D 2655, D 2656, UL 854, UL 44,ASTM B 801, ASTM B800 .
2.1 CONSTRUCTIVE CHARACTERISTICS
Each material used in the conductor will be compatible with all other materials used in the manufacture of concentric conductor.
Concentric conductor consists of one or two conductors which in turn are coated with a bare conductor distributed helically around the conductors.
According to these configurations will have a phase and outer concentric neutral (bipolar), or two phases and these external neutral (tripolar)
Section of all conductors that form the concentric conductor of both phases as the concentric neutral is the same.
Conductor:
The materials used in the manufacture of concentric aluminum conductors formed by wires aluminum 8000 serises , or 1350 Al, or Copper
shall comply with the provisions of ASTM standard .
Isolation:
Each phase conductor will contain an insulating layer of XLPE for a temperature of 90 C. in the bipolar cables, over the insulating layer will be the braided neutral conductor helically with a passage between 8 and 16 times the outer diameter. In the tripolar cables over the isolation of each phase will have a PVC insulation filling in the joint of both cables and over this will be placed the neutral conductor.
Will be put over the concentric neutral conductor a tape and over this outer layer of PVC. Must ensure the tightness of the set plus adequate resistance to ultraviolet rays (UV),Covering the entire concentric conductor will be placed a PVC coating.
4 mm , 6mm , 10mm concentric cable
size | Phase conductor (no.x OD) | Nominal Insulation Thickness | Earth Size | Earth Conductor (No.*OD) | Nominal Sheath thickness | Approximade cable OD | Approximate cable Mass |
mm2 | mm | mm | mm² | MM | mm | MM | kg/km |
4 | 7*0.85 | 1.2 | 4 | 32*0.4 | 1.4 | 8.6 | 121 |
6 | 7*1.04 | 1.2 | 6 | 26*0.54 | 1.4 | 9.4 | 160 |
10 | 7*1.35 | 12 | 10 | 20*0.8 | 1.4 | 11.0 | 249 |
SNE | |||||||
10 | 7*1.35 | 1.2 | 7*1.33 | 3*1.78 | 1.6 | 12.8 | 320 |
16 | 7*1.67 | 1.2 | 7*1.76 | 3*2.2 | 1.6 | 14.5 | 485 |
6AWG , 8AWG ,4AWG concentric cable
ASTM 600/1000v | |||||||||||
Core | AWG | Structure Size (mm) | Copper cable (kg/km) | ||||||||
Conductor | Insulation | Concentric conductor | Outer sheath | ||||||||
Single wire | XLPE | Single wire | UV-PVC | ||||||||
No. | Dia. | Thick | No. | Dia. | Thick | Dia. | |||||
2 | 16 | 7 | 0.49 | 1.14 | 39 | 0.321 | 1.14 | 6.82 | 81.46 | ||
2 | 10 | 7 | 0.98 | 1.14 | 34 | 0.511 | 1.14 | 8.67 | 172.04 | ||
2 | 8 | 7 | 1.23 | 1.14 | 25 | 0.643 | 1.14 | 9.68 | 221.58 | ||
2 | 6 | 7 | 1.55 | 1.14 | 25 | 0.813 | 1.14 | 10.98 | 160.50 | ||
2 | 4 | 7 | 1.96 | 1.14 | 27 | 1.020 | 1.14 | 12.62 | 509.26 | ||
IEC 60502-1 IEC 60228 600/1000v | |||||||||||
Size (mm2) | Structure Size mm | Copper cable (kg/km) | |||||||||
Concuctor | Insulation | Concentric conductor | Outer sheath | ||||||||
Single wire | Dia. | PVC | Single wire | UV-PVC | |||||||
No. | Dia. | Thick | No. | Dia. | Thick | Dia. | (kg/km) | ||||
10 | 7 | 1.35 | 4.05 | 1.55 | 20 | 0.85 | 1.4 | 11.79 | 301.55 | ||
16 | 7 | 1.7 | 5.1 | 1.55 | 32 | 0.85 | 1.4 | 12.84 | 431.7 | ||
25 | 7 | 2.14 | 6.42 | 1.6 | 29 | 1.13 | 1.5 | 15.02 | 647.46 | ||
16 | 7 | 1.7 | 5.1 | 1.55 | 26 | 1.13 | 1.4 | 13.42 | 244.16 | ||
25 | 7 | 2.14 | 6.42 | 1.6 | 29 | 1.13 | 1.5 | 15.02 | 307.3 | ||
35 | 19 | 1.53 | 7.65 | 1.65 | 27 | 1.35 | 1.6 | 16.99 | 390.15 |