AHKC-EKAA
Hall Type
Analog Output
Injection
Metal
0.5G
Industry Automation
CE
Non-Customized
Split Core Open-Loop Hall Current Sensor
OEM ODM
DC 0~500A
4-20mA
Class 0.5
12V/24V
20mm
ACREL
Fob Shanghai
China
Product Description
Product DescriptionAHKC-EKAA Split Core Open-loop Hall Effect Current Sensor

Hall current sensors are mainly used to isolate and convert AC, DC, pulse and other complex signals. After signals are converted according to the Hall Effect Theory, they can be directly acquired by AD, DSP, PLC, secondary instruments and other devices. Hall current sensors are widely applicable for acquisition and feedback control of current signals in the current monitoring, battery application, inverter, solar power management, direct current cabinet, DC motor drive, electroplating, welding, frequency converter, UPS servo control systems. They feature the quick response, wide range of measurement, high precision, strong overload capacity, good linearity and excellent anti-interference performance.
Dimension
Wiring
Technical Parameters
Quotation
AHKC-EKAA Split Core Open-loop Hall Effect Current Sensor
General

Hall current sensors are mainly used to isolate and convert AC, DC, pulse and other complex signals. After signals are converted according to the Hall Effect Theory, they can be directly acquired by AD, DSP, PLC, secondary instruments and other devices. Hall current sensors are widely applicable for acquisition and feedback control of current signals in the current monitoring, battery application, inverter, solar power management, direct current cabinet, DC motor drive, electroplating, welding, frequency converter, UPS servo control systems. They feature the quick response, wide range of measurement, high precision, strong overload capacity, good linearity and excellent anti-interference performance.
Dimension
![]() Botton View | ![]() Front View | ![]() Side View |
Wiring
![]() Clamp-on (Split-core) Installation on Measuring DC Cable | ![]() |
Technical parameters | Data | |||
Split/closed open-loop | Hall (true RMS) | |||
Output | Nominal value | Voltage: ±5V/±4V | Current: 4-20mA | |
Zero offset voltage (current) | Voltage: ±20mV | Current:±0.05mA | ||
Offset voltage (current) drift | Voltage: ≤±1.0mV/ºC | Current:±0.04mA/ºC | ||
Linearity | ≤0.2%FS | |||
Power voltage | DC±15V | DC 24V | ||
Bandwidth | 0-20kHz | |||
Response time | ≤5us | ≤1ms | ||
Dielectric strength | Permissible 2500VAC between input/ output and power supply at the power frequency | |||
Accuracy class | 1.0 | |||
Ambient conditions | Temperature | Operating temperature:-25ºC-+70ºC; storage temperature: -40ºC-+85ºC | ||
Humidity | ≤95%RH, no dew, no aggressive gas | |||
Altitude | ≤3500m |
Quotation
Shape | Model | Rated current | Power supply | Rated output | Measuring Aperture(mm) | FOB Shanghai(USD) |
![]() | AHKC-EKA | 0~(20-500)A | ±15V | 5V/4V | φ20 | 16 |
AHKC-EKAA | DC 0~(50-500)A | 12V/24V | 4~20mA | φ20 | 16 | |
AHKC-EKDA | AC 0~(200-1000)A | 12V/24V | 4~20mA | φ20 | 18 | |
AHKC-EKB | 0~(200-1000)A | ±15V | 5V | φ40 | 31 | |
AHKC-EKBA | DC 0~(200-1000)A | 12V/24V | 4~20mA | φ40 | 31 | |
AHKC-EKBDA | AC 0~(200-1000)A | 12V/24V | 4~20mA | φ40 | 34 | |
![]() | AHKC-EKC | 0~(500-1500)A | ±15V | 5V/4V | φ55 | 41 |
AHKC-EKCA | DC 0~(500-1500)A | 12V/24V | 4~20mA | φ55 | 41 | |
WHKC-EKCDA | AC 0~(500-1500)A | 12V/24V | 4~20mA | φ55 | 41 | |
AHKC-K | 0~(400-2000)A | ±15V | 5V | 64x16 | 39 | |
AHKC-KAA | DC 0~(400-2000)A | 12V/24V | 4~20mA | 64x16 | 39 | |
AHKC-KDA | AC 0~(400-2000)A | 12V/24V | 4~20mA | 64x16 | 55 | |
![]() | AHKC-H | 0~(500-3000)A | ±15V | 5V | 82x32 | 55 |
AHKC-KA | 0~(500-5000)A | ±15V | 5V | 104x36 | 56 | |
AHKC-HB | 0~(2000-8000)A | ±15V | 5V | 132x52 | 134 | |
0~(10000-20000)A | ±15V | 5V | 132x52 | 195 | ||
AHKC-HBAA | DC 0~(2000-8000)A | 12V/24V | 4~20mA | 132x52 | 260 | |
DC 0~(10000-20000)A | 12V/24V | 4~20mA | 132x52 | 520 | ||
AHKC-HBDA | AC 0~(2000-8000)A | 12V/24V | 4~20mA | 132x52 | 260 | |
AC 0~(10000-20000)A | 12V/24V | 4~20mA | 132x52 | 520 |