Anti-Magnetic Field 12VDC 100A Motor Latching Relay for Energy Meter

Price $3.20 Compare
Min Order 1 Piece
Shipping From Shanghai, China
Popularity 262 people viewed
Quantity
+-
 

IVY METERING CO., LTD.

VIP   Audited Supplier 7 years
Profile Certified by SGS/BV
IM-M1202
Electromagnetic Relay
Household Appliances Relay, for Energy-Saving, Remote Control, Energy Meter
1
Dc
1
High Power Relay
Sealed Relay
Electromagnetic Type
Miniature
Electric Parameter Relay
Compact Im-M1202 Magnetic Immune Latching Relay Fo
Agsno2
100A, 250VAC
12VDC
Black
IVY
Cartons/Pallet
29*23.5*16mm
Zhejiang, China
8536411000
Product Description


12VDC Latching Relay 100A for Single Phase Energy Meter

Product Description

1, Latching Relay

1) 100A switching capability.

2) Low coil consumption and ultra-low temperature rise.

3) Low contact resistance.

4) High resistance to shocks and vibrations.

5) Outline dimensions: 29x23.5x16mm.

6) Custom-made busbar configuration.

7) UC3 certified (IEC62055-31).

2 Applications

1) Electrical meter

2) Automatic meter reading(AMR)

3) All kinds of household electric applications and automatic control devices etc.

3,  Furniture.

1) Compact configuration

2) Small size

3) High switching capacity


Basic DataDimensions(mm)29×23.5×16
Weight ( g )≈40g
Contact Arrangement1A/1B
Contact MaterialAgSnO2
Ambient Temperature-40~+75ºC
Vibration10~50Hz,1.5mm
Shock1000m/s²,(100g)
Specifications DataPower Consumption<3W
Operating Voltage10.5-16V
Max. Switching Current100A
Surge Current6000A/10ms
Motor Resistance32(1±15%
Contact Voltage<60mV
Contact Resistance≤1.0
Dielectric StrengthMotor to Contact>4000VAC,50/60Hz 1min
Across Open Contact>2000VAC,50/60Hz 1min
Electrical Life(120 cycles/H)10,000
(resistance 5 k + perceptual 5 k, co ϕ = 0.5)
Mechanical Life(3600 cycles/H)100,000
Pulse Time60ms(Advise 60ms~100ms)
Picking-up Time≤60ms
Release Time≤60ms
Insulation Resistance>1000MΩ(500VDC)
           Cautions of Latching Relay:

             1. Suggestions of relay's input
            (1) Polarity- Please check the polarity inside of our technical specification, if a single coil then"+ -" or "- +"is fine,
            you can change it with one pulse. If double coil then it's necessary to confirm "-+-" or "+-+" before leaving our factory.
            (2)Driving-Please energize the relay at our recommended pulse width, and rated voltage for reliable performance of 1.5
            times or 2 times of value or lower driving condition plz confirm with our engineer.
            (3) Contact status may be changed during transportation or installation due to the impact of external force,
            therefore please reset to the required status.
 
            2. Suggestions for the relay's output
            (1)When choosing the relay with a hard connection, please avoid the external force on load terminals during or after
            the installation.
            (2)When the relay will be connected with screws or bolts to the relays' terminals, plz make sure your connection is
            fastened and prevent the relay from damage or other safety problems due to temp. Rise..
            (3)The sampling signal wires of products are limited, please do not pull or torque during installation.