Autoinjector Testing Machine Compatible with Main Insulin Pen Autoinjector Syringe International Manufacturers

Price $170000.00 Compare
Min Order 1 Piece
Shipping From Guangdong, China
Popularity 260 people viewed
Quantity
+-
 

Shenzhen Healing Biotech Co., Ltd.

VIP   Audited Supplier 1 year
Profile Certified by SGS/BV
HL903
Automatic Testing
6-8PCS/Min
Acceptable
Manual
Container
1100mm*1240mm*1950mm
China
Product Description


Device Features
  1. One pen for all test items and complied with regulatory requirements
  2. Test data can be traced and audited
  3. Can be used for production in- process control and product development
  4. Compatible with the products from main international manufacturers
Parameter
 
Testing MachineParameter value
External Dimension1100mm*1240mm*1950mm
Speed6-8pcs/min
Feeding ModeManual
Input Pressure≥0.6MPa
Input VoltageAC 220V 50Hz
Cleanliness<100,000 class in equipment
Data Detection MethodPressure sensor,visual inspection,electronic scales
Sensor Basic Accuracy0.2N
Vision Basic Accuracy 0.02mm
Basic Precision of Electronic Scales0.001g
Software Control MethodsPC
Software Human Machine InteractionIndustrial controller
Product Information Recording MethodsScanner
Operating Temperature20±5°C
Operating Relative humidity 30-60 percent non-condensation
Air EnvironmentNo dust,flammable and explosive,corrosive gases
Working SystemProgression
Safety ProtectionSafety door lock+dual start button+safety light curtain+emergency stop switch


Testing Items
 
Test ItemDescriptionStandardAccuracyReference Standards
Cap Removal ForceMinimum force required to remove the pen cap6-55N0.2NISO 14971, YBB40012012
Activation ForceMinimum force required to press and start the injection process2-15N0.2NISO 11608-5, ISO 14971
Trigger ForceForce required to initiate injection2-15N0.2NISO 11608-5, ISO 14971
Holding ForceForce to maintain the injection process2-15N0.2NISO 11608-5, ISO 14971
Rebound ForceInner shell rebound force after injection completed> 0N0.2NISO 11608-5, ISO 14971
Defeat ForceMinimum force required to break the needle cap protection device through vertical pressing> 48N0.2NISO 11608-5, ISO 14971, ISO 23908
Injection VolumeWeight of collected liquid after injection> 1 ml0.001gISO 11608-1, ISO11608-5, YBB40012012, ISO 14971
Injection TimeTime interval from plunger start to stop moving5-10s0.04sMDER 2015:8 437-484
Needle Penetration DepthInjection depth4-8 mm0.02 mmISO 11608-5, ISO 14971
Needle Safety DistanceNeedle tip protection distance after injection≥ 3.7 mm0.02 mmISO 11608-5, ISO 23908
 