BS ASTM NFC Caai Cross-Linked Polyethylene XLPE PVC Insulated AAC AAAC ACSR Conductor Triplex Service Drop Cable Electric Wire Electrical Cable

Price $19.90 Compare
Min Order 500 Meters
Shipping From Henan, China
Popularity 365 people viewed
Quantity
+-
 

Henan Jinshui Cable Group Co., Ltd.

VIP   Audited Supplier 18 years
Profile Certified by SGS/BV
ABC cable
Insulated
Stranded
Overhead
Aluminum
Bare
PVC
Round Wire
Overhead Power Transmission
ISO9001, CE
Jinshui
JINSHUI
Wooden Drum
Triplex
China
8544492100
Product Description
Cross-Linked Polyethylene XLPE Insulated Triplex Service Drop Cable

0.6/1kv overhead insulated cable
 Product Description
1. Application of Service Drop Cable: 
Service Drop Cable(ABC CABLE) are mainly used for electric power tranmission, rebuiding of urban and forest regions. They can improves safety and reliance of electrified wire netting. 

2. Type of Service Drop Cable: 
Service Drop Cable(ABC CABLE) covers mainly three types: 
Duplex Service Drop 
Triplex Service Drop 
Quadruplex Service Drop 

The cable can be produced whose construction is phase conductor with neutral bare conductor or phase conductor with insulated neutral conductor, etc. And we can still produce the cables according to the request of customers. 

3. Detaild Introduction of Service Drop Cable 
3.1 Duplex Service Drop 

Applications 
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum. 

Construction 
Concentic strand or cmpressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger. 

3.2 Triplex Service Drop 
Applications 
To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation. 

Construction 
Concentic strand or cmpressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger. 

3.3 Quadruplex Service Drop 
Applications 
Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors. 

Construction 
Conductors are concentrically standed, compressed 1350-H19 aluminium. Insulated with either polyethylene or XLPE. Neutral messengers aer concentrically stranded 6210 AAAC, AAC or ACSR.
 
 
Standards: 

1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes. 
2. B-231 Aluminum Conductors, Concentric-Lay-Stranded. 
3. B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR). 
4. B-399 Concentric-Lay_Stranded 6201-T81 Aluminum Alloy Conductors. 
5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR). 
6. Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474
CodeSizePhase CoreNeutral CoreApprox. Weight
PhaseNeutralWire No.Insulation Thick.Wire No.Wire Dia.Rated Tensile Strength
AWG/MCM/mm/mmkNkg/km
Pekingese6611.1471.562.5392
Collie6671.1471.562.5394
Dachshund4411.1471.963.91139
Spaniel4471.1471.963.91141
Doberman2271.1472.475.99216
Malemute1/01/0191.5273.128.84347

(Duplex - ACSR Neutral
CodeSizePhase CoreNeutral CoreApprox. Weight
PhaseNeutralWire No.Insulation Thick.Wire No.
(Al.+St.)
Wire Dia.Rated Tensile Strength
AWG/MCM/mm/mmkNkg/km
Setter6611.146+11.685.24111
Shepherd6671.146+11.685.24113
Eskimo4411.146+12.128.32171
Terrier4471.146+12.128.32173
Chow2271.146+12.6712.7266
Bull1/01/0191.526+13.3719.3427

Duplex - AAAC Neutral
CodeSizePhase CoreNeutral CoreApprox. Weight
PhaseNeutralWire No.Insulation Thick.Wire No.Wire Dia.Rated Tensile Strength
AWG/MCM/mm/mmkNkg/km
Chihuahua6611.1471.684.9298
Vizsla6671.1471.684.92100
Harrier4411.1472.127.83149
Whippet4471.1472.127.83151
Schnauzer2271.1472.6712.4231
Heeler1/01/0191.5273.3718.9372

Triplex - AAC Neutral
CodeSizePhase CoreNeutral CoreApprox. Weight
PhaseNeutralWire No.Insulation Thick.Wire No.Wire Dia.Rated Tensile Strength
AWG/MCM/mm/mmkNkg/km
Haiotis6611.1471.562.53146
Patella6671.1471.562.53150
Fusus4411.1471.963.91219
Oyster4471.1471.963.91224
Clam2271.1472.475.99338
Murex1/01/071.5273.128.84544
Purpura1/01/0191.5273.128.84545
Nassa2/02/071.5273.5011.1671
Melita3/03/0191.52192.3914.7830
Portunus4/04/0191.52192.6817.81025
Nannynose336.4336.4192.03193.3827.41649

Triplex - ACSR Neutral
CodeSizePhase CoreNeutral CoreApprox. Weight
PhaseNeutralWire No.Insulation Thick.Wire No.
(Al.+St.)
Wire Dia.Rated Tensile Strength
AWG/MCM/mm/mmkNkg/km
Paludina6611.146+11.685.24166
Voluta6671.146+11.685.24170
Whelk4411.146+12.128.32251
Periwinkle4471.146+12.128.32255
Conch2271.146+12.6712.7389
Neritina1/01/071.526+13.3719.3624
Cenia1/01/0191.526+13.3719.3625
Runcina2/02/071.526+13.7823.6771
Triton2/02/0191.526+13.7823.6772
Cherrystone3/03/071.526+14.2529.4956
Mursia3/03/0191.526+14.2529.4957
Razor4/04/071.526+14.7737.11187
Zuzara4/04/0191.526+14.7737.11188
Limpet336.4336.4192.0318+13.4738.21733
Scallop4611.146+11.685.24217
Strombus4671.146+11.685.24222
Cockle2471.146+12.128.32335
Janthina1/0271.526+12.6712.7539
Ranella1/02191.526+12.6712.7540
Cavolinia2/0171.526+13.0015.9665
Clio2/01191.526+13.0015.9666
Sanddollar3/01/071.526+13.3719.3821
Aega3/01/0191.526+13.3719.3823
Cuttlefish4/02/071.526+13.7823.61017
Cerapus4/02/0191.526+13.7823.61018
Cowry336.44/0192.036+14.7737.11633

Triplex - AAAC Neutral
CodeSizePhase CoreNeutral CoreApprox. Weight
PhaseNeutralWire No.Insulation Thick.Wire No.Wire Dia.Rated Tensile Strength
AWG/MCM/mm/mmkNkg/km
Minex6611.1471.684.92152
Hippa6671.1471.684.92156
Prawn4411.1472.127.83229
Barnacles4471.1472.127.83233
Shrimp2271.1472.6712.4354
Gammarus1/01/071.5273.3718.9569
Leda1/01/0191.5273.3718.9570
Dungenese2/02/071.5273.7823.8702
Cyclops2/02/0191.5273.7823.8703
Flustra3/03/0191.5274.2530.0869
Lepas4/04/0191.5274.7737.81077
Artemia4611.1471.684.92203
Crab4671.1471.684.92208
Solaster2471.1472.127.83313
Sandcrab1/0271.5272.6712.4504
Echinus1/02191.5272.6712.4505
Crayfish2/0171.5273.0015.7621
Sipho2/01191.5273.0015.7622
Fulgar3/01/0191.5273.3718.9767
Arca4/02/0191.5273.7823.8949

Quadruplex - AAC Neutral
CodeSizePhase CoreNeutral CoreApprox. Weight
PhaseNeutralWire No.Insulation Thick.Wire No.Wire Dia.Rated Tensile Strength
AWG/MCM/mm/mmkNkg/km
Clydesdale4411.1471.963.91299
Pinto4471.1471.963.91306
Mustang2271.1472.475.99461
Criollo1/01/0191.5273.128.84744
Percheron2/02/0191.5273.5011.1914
Hanoverian3/03/0191.52192.3914.71127
Oldenburg4/04/0191.52192.6817.81385
Lippizaner336.4336.4192.03193.3827.42236

Quadruplex - ACSR Neutral
CodeSizePhase CoreNeutral CoreApprox. Weight
PhaseNeutralWire No.Insulation Thick.Wire No.
(Al.+St.)
Wire Dia.Rated Tensile Strength
AWG/MCM/mm/mmkNkg/km
Morochuca6611.146+11.685.24221
Chola6671.146+11.685.24227
Morgan4411.146+12.128.32331
Hackney4471.146+12.128.32338
Palomino2271.146+12.6712.7511
Costena1/01/0191.526+13.3719.3824
Grullo2/02/0191.526+13.7823.61015
Suffolk3/03/0191.526+14.2529.41254
Appaloosa4/04/0191.526+14.7737.11554
Bronco336.4336.4192.0318+13.4738.22321
Gelding336.44/0192.036+14.7737.12221

Quadruplex - AAAC Neutral
CodeSizePhase CoreNeutral CoreApprox. Weight
PhaseNeutralWire No.Insulation Thick.Wire No.Wire Dia.Rated Tensile Strength
AWG/MCM/mm/mmkNkg/km
Bay6611.1471.684.92207
French Coach6671.1471.684.92213
German Coach4411.1472.127.83309
Arabian4471.1472.127.83316
Belgian2271.1472.6712.4476
Shetland1/01/0191.5273.3718.9768
Thoroughbred2/02/0191.5273.7823.8945
Trotter3/03/0191.5274.2530.01166
Walking4/04/0191.5274.7737.81442