HD-100V100A-8CH
12 Months Warranty & Life-Time Sale Service
1 Year
Finished Batteries Tester
All
Lithium-ion Battery
Customized
Less Than 75dB
Can Be Customized
Less Than 5%
More Than 92%
HONGDIAN
Wooden Case
Size: 686mm X 700mm X 1960mm
Dongguan, China
9030899090
Product Description
Product Description
HONGDIAN Battery charging and discharging tester is a special instrument for testing lithium battery pack, lead-acid battery pack, portable mobile power module and other battery packs with full series voltage 30V, 60V, 100V, 120V.
The equipment has an advanced modular design and is equipped with a high-performance digital signal processor. It has powerful floating-point computing ability, multi-task real-time operation, all channels can be controlled independently, and it supports cross-device operation, multi-channel parallel master-slave synchronization technology, and the master-slave clock error is less than 1 ms. The voltage and current accuracy of the conventional model is five ten thousandths, and the customized model can reach two ten thousandths. It supports automatic current grading and the dynamic response of current switching is ≤ 5 ms.
The equipment realizes man-machine interaction, the channel information interface displays the equipment IP selection list, the display information and data unit can be set, the working mode color can be set, the process information can be displayed, and the test process is intuitive. The left side of the data analysis interface is a curve, and the right side is a data list, which can display curves or data independently or simultaneously. Support a variety of information to query historical data, and export reports in various formats. The process editing interface adopts script editing mode, and there are many types of work steps and deadline conditions to choose from.








HONGDIAN Battery charging and discharging tester is a special instrument for testing lithium battery pack, lead-acid battery pack, portable mobile power module and other battery packs with full series voltage 30V, 60V, 100V, 120V.
The equipment has an advanced modular design and is equipped with a high-performance digital signal processor. It has powerful floating-point computing ability, multi-task real-time operation, all channels can be controlled independently, and it supports cross-device operation, multi-channel parallel master-slave synchronization technology, and the master-slave clock error is less than 1 ms. The voltage and current accuracy of the conventional model is five ten thousandths, and the customized model can reach two ten thousandths. It supports automatic current grading and the dynamic response of current switching is ≤ 5 ms.
The equipment realizes man-machine interaction, the channel information interface displays the equipment IP selection list, the display information and data unit can be set, the working mode color can be set, the process information can be displayed, and the test process is intuitive. The left side of the data analysis interface is a curve, and the right side is a data list, which can display curves or data independently or simultaneously. Support a variety of information to query historical data, and export reports in various formats. The process editing interface adopts script editing mode, and there are many types of work steps and deadline conditions to choose from.

AC input parameters | Input power supply | AC 380V±10% 50/60±5Hz |
Power factor | ≥99%(full load) | |
THDI | ≤5%(full load) | |
Input impedance | ≥1 MΩ | |
Feedback efficiency | ≥92%(full load) | |
DC output parameters | Voltage range | Charging Voltage: 0V ~ 150V Discharging Voltage: 6V ~ 150V |
Voltage Accuracy | ±0.05%FS | |
Voltage Resolution | 1mV | |
Current Range | -240 ~ 240A | |
Current Accuracy | ±0.05%FS | |
Current Resolution | 1mA | |
Current Response Time | 10ms(10%FS ~ 90%FS) | |
Charge/Discharge Conversion Time | 20ms(-90%FS ~ 90%FS) | |
Channel Control Mode | All channels can be independently controlled. | |
Auxiliary channels | Each channel is equipped with an auxiliary temperature channel. | |
Working step functional characteristics | Support experimental testing | Battery cycle life test, battery capacity test, battery charge/discharge characteristic test, battery charge retention test, battery charge and discharge efficiency test, battery charge and discharge endurance test. |
Minimum recording time of data | 10ms | |
Number of steps | 2000 | |
Cycles | 65535 | |
Cyclic nesting | 5 | |
Charge-discharge mode | Standing, pausing, constant current charging CC, constant voltage charging CV, constant resistance charging CR, constant current and constant voltage charging CCCV, constant power charging CP, constant current discharging DC, constant power discharging DP, constant resistance discharging DR, DC internal resistance test (DCIR). | |
Cut-off condition | Voltage, current, capacity, energy, time, power, cycle times, BMS parameters, user-defined advanced parameters (supporting one or more logical AND or combinations). | |
Type of execution action | Jump, Pause, Protect, Next | |
485/DBC file import | Support file editing, saving and importing, 485/CA for each channel. | |
DC internal resistance test (DCIR) | It supports DCIR step and hardware real-time calculation, and supports (V1-V2)/(I1-I2) and (v1-v2)/I. | |
Data export mode | Excel and CSV format export | |
Defencive function | AC side protection | Power grid voltage over/under-voltage protection, surge protection, islanding protection, over/under-frequency protection, hardware over-temperature protection and self-detection protection, etc. |
DC side protection | Bus overvoltage and undervoltage protection, hardware overtemperature protection, battery channel line reverse connection protection, etc. | |
Battery side comprehensive protection | Upper and lower limits of total battery voltage, upper and lower limits of single battery voltage, upper and lower limits of battery temperature, upper and lower limits of battery charging and discharging current, upper and lower limits of battery capacity, BMS communication drop protection, network drop protection, etc. | |
Power failure data protection | It has the function of memory power failure protection, which can effectively avoid data loss caused by power failure or continue to run at the process breakpoint without modifying the process after incoming call. | |
Protection grades | IP20 | |
Operating temperature range | 0ºC-45ºC | |
Cooling mode | Forced cold air | |
Noise level | ≤80dB |







1.BMS free docking development
2. Accuracy 0.05%
3. Charge and discharge efficiency 92%
4. Avant-garde voltage protection below 60v, without a protection board, our software can predict 7 volts in advance
5. Our chassis appearance design is exquisite, small, in line with the optimal solution to heat dissipation effect, while using Delta fan, IGBT Infineon, the best configuration to ensure heat dissipation effect