NA2XS(FL)2Y
Construction, Underground, Industrial, Power Station
Low and Medium Voltage Cable
XLPE
MDPE
Round Wire
Red Copper Wire
ISO, CCC, CE, VDE
Na2xsfl2y
Steel Wire
30%+70%
EXW, Fob, CIF
Guowang Cable Group
No
Wooden Drum
50-630mm2
China
8544601290
Product Description
Best Price NA2XS(FL)2Y for Fixed Outdoor Installations Cables
Medium voltage power cables with additional waterblocking properties for distribution networks and generation units, suitable for external installation including in direct in ground and in buried cable ducts. UV Resistant

Voltage Rating Uo/U (Um)
8.7/15 (17.5) kV
Temperature Rating
-20°C to +60°C
Permissible Conductor Operating Temperature:
+90°C
Permissible Short Circuit Temperature up to 5 sec:
250°C
Minimum Bending Radius
15 x overall diameter
STANDARDS
IEC 60502-2
8.7/15 (17.5) kV
Temperature Rating
-20°C to +60°C
Permissible Conductor Operating Temperature:
+90°C
Permissible Short Circuit Temperature up to 5 sec:
250°C
Minimum Bending Radius
15 x overall diameter
STANDARDS
IEC 60502-2
Conductor
Class 2 Stranded Aluminum
Conductor Screen
Semi-conductive material
Insulation
XLPE (Cross-Linked Polyethylene)
Insulation Screen
Semi-conductive material (bonded)
Longitudinal Waterblock
Semi-conductive water swelling tape
Metallic Screen
Copper Wires and Tape
Longitudinal Waterblock
Non-conductive water swelling tape
Radial Waterblocking
Al/PET (Aluminium/Polyester) Tape tightly bonded to sheath
Outer Sheath
MDPE (Medium Density Polyethylene)
Sheath Colour
Red Black
Class 2 Stranded Aluminum
Conductor Screen
Semi-conductive material
Insulation
XLPE (Cross-Linked Polyethylene)
Insulation Screen
Semi-conductive material (bonded)
Longitudinal Waterblock
Semi-conductive water swelling tape
Metallic Screen
Copper Wires and Tape
Longitudinal Waterblock
Non-conductive water swelling tape
Radial Waterblocking
Al/PET (Aluminium/Polyester) Tape tightly bonded to sheath
Outer Sheath
MDPE (Medium Density Polyethylene)
Sheath Colour
Red Black

Conductor Size | Screen Size | Nominal Diameter of Conductor (MM) | Nominal Insulation Thickness (MM) | Nominal Overall Diameter (MM) | Reference Weight (KG/KM) |
50 | 16 | 8.1 | 4.5 | 28.1 | 720 |
70 | 25 | 9.7 | 4.5 | 29.4 | 890 |
95 | 35 | 11.4 | 4.5 | 31.2 | 1100 |
120 | 50 | 12.7 | 4.5 | 32.4 | 1330 |
150 | 50 | 14.5 | 4.5 | 34.1 | 1440 |
185 | 50 | 15.9 | 4.5 | 35.7 | 1580 |
240 | 50 | 18.6 | 4.5 | 37.8 | 1780 |
300 | 50 | 20.7 | 4.5 | 39.9 | 1990 |
400 | 50 | 23.5 | 4.5 | 42.8 | 2300 |
500 | 50 | 26.5 | 4.5 | 46.3 | 2710 |
630 | 50 | 30.2 | 4.5 | 46 | 3190 |