Best Quality 0-1A 0-5A Input DC Current Transducer with 0-20mA 4-20mA Output, with RS485 Communication

Price $50.00 Compare
Min Order 1 Piece
Shipping From Chongqing, China
Popularity 367 people viewed
Quantity
+-
 

Chongqing Blue Jay Technology Co., Ltd

VIP   Audited Supplier 2 years
Profile Certified by SGS/BV
BJ-QPA
Electromagnetic
Digital Output
SemiConductor Integrated
Metal
0.5G
Switching Power Supply
IP65
ISO
Customized
IP54
Current Sensor
Modbus
Analog Sensor
Analog Input, Anglog Output, Digital Output
Blue Jay
Carton
10*10cm
China
Product Description
 
The Voltage sensor converts an AC / DC voltage or current input into a load-independent output signal. It has excellent temperature characteristics and good working stability. The output signal is based on the root mean square(RMS) measurement of the input signal and hence the transducer can be used with distorted waveforms. The unit conforms to IEC 60688. In addition, the voltage transducer rs485 meets the insulation requirements of IEC 60255-5, clauses 5, 6, and 8 as well as the high-frequency disturbance test of IEC 60255-22 for Class III test voltage.
 
Compared with the past transducers, the QPV AC voltage transducer, made of new technologies and materials, has been greatly improved in circuit, process, structure, etc., making its measurement accuracy higher and work more stable.
 

Feature

* 2/0.5 measurement accuracy
* Support customized parameters
* RMS measurement and output
* 500ms response time
* 35mm Din rail mounting
* High load capacity and reliability
* Low ripple output * A wide range of both D.C. current and voltage inputs are offered.
 

Specification

Signal Inputs
 
Input rating
QPA 0-1A, 0-5A, 0-10A
Overload
1.2 times rated continuous;
5sec @ 10 times of rated current
1sec @ 2 times of rated voltage
Burden
0.5VA
Measurement Output
 
Standard outputs
4~20mA or 0~5V
(others on request)
0~20mA;
 
5~10V;
 
0~10V;
Ripple
<0.5% peak to peak
Load Resistance
Current output: 0
 
Voltage output: Lr>10KΩ
Measurement Accuracy
 
Reference IEC 60688
0.5% or 0.2% @ F.S.
Adjustment
Potentiometer "ZERO" and "SPAN"
Frequency influence
<0.02% per Hz
Load influence
<0.25% of F.S. for specific load range
Auxiliary Supply
 
Rating
85-265Vac/dc,
Optional 12V, 24V, 48VDC
Consumption
<3VA
Galvanic isolation between I/O and AUX
 
Test voltage
2KV RMS 50Hz for 1 minute
impulse
4KV 1.2/50µsec waveform
Temperature requirements
 
Operating
-10~55C
Storage
-40~70C, 20 ~ 93%RH; Noncondensing
 
 
 
 
 
 
 
 
 

Application


Company Profile

Certifications

Our Service

 

FAQ

 

Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA