Biobase Bk-Gc7820 Test Equipment Gas Chromatograph Gas Chromatograph

Price $4500.00 Compare
Min Order 1 Piece
Shipping From Shandong, China
Popularity 237 people viewed
Quantity
+-
 

Biobase Biodustry (Shandong) Co., Ltd.

VIP   Audited Supplier 14 years
Profile Certified by SGS/BV
BK-GC7820
Online Technical Support
1 Year
The Analysis of Environmental Samples
Gamma Ray Spectrometer
Double
FID
≤7.5%
CE, ISO
Liquid Solvent
Gas
Gas Chromatography
Capilary Column
0.2~0.5mm
Rt~450 Degree
+-0.1 Degree
16-Phase
40 Degree/Min
Fid
<=3X10-12g/S (Sample: N-Hexadecane)
<=1X10-13A/30min
>=107
800*570*650mm
75kg
BIOBASE
Carton, Wooden
ISO
China
Product Description
Features:

5.7-inch LCD display indicates temperature, time and gas flow.Self-test, power protection, keyboard lock, automatic ignition and anti power mutation interference function.Can connect with Internet, realize data transfer and program upgrade automatically.Equipped with a flame ionization detector (FID), and TCD, ECD, FPD, NPD are optional. Can install four detectors at the same time.Can install packed column and capillary column at the same timeDouble column compensation function, which can effectively restrain baseline drift and the influence of background noise.Large capacity oven (300*280*180mm) can hold 2 pcs 0.32mm diameter capillary column (length: 80m).Better thermal insulation effect: when the temp. of oven, vaporizing chamber and detector reach 300ºC, the max. temp. of outer chamber is 40ºC.
9. With chromatography workstation software to process data.


Technical specifications:
ModelBK-GC7820
OvenTemp. RangeRT~450ºC
Temp. Accuracy≤±0.1ºC
Temp. Program16-phase
Max. Temp. Heating Rate40ºC/min
DetectorHydrogen Flame Ionization Detector (FID)Detection limit: ≤3×10-12g/s
(Sample: n-hexadecane)
Baseline drift: ≤1x10-13A/30min
Linear range: ≥107
Thermal Conductivity Detector (TCD) (Optional)Sensitivity: >10000mv.ml/mg
(Sample: n-hexadecane)
Linear range: ≥105
Electron Capture Detector (ECD) (Optional)Detection limit: ≤1×10-14g/ml
(Sample: n-hexadecane δ-666)
Linear range: ≥103
Flame Photometric Detector (FPD) (Optional)Detection limit: ≤2×10-11g/s (S of thiophene)
Detection limit: ≤1×10-12g/s (P of methyl parathion)
Linear range (S): ≥102
Linear range (P): ≥103
Nitrogen and Phosphorus Detector (NPD) (Optional)Detection limit: ≤1×10-12g/s (Azobenzene)
Detection limit: ≤1×10-12g/s (Marla sulfur phosphorous)
Linear range: ≥103
Power SupplyAC110/220V±10%, 50/60Hz
Standard AccessoryFID detector, Chromatography workstation software
Optional AccessorySample injection system, TCD, ECD, FPD and NPD detector, Chromatographic column.
Package Size (W*D*H)800*570*650mm
Gross Weight75kg