Biobase Laser Particle Size Analyzer BPSA-6100D
Product Feature
* Advanced optical design: It by using a convergent Fu Liye transform test technique to ensure the maximum range in the short focal length, effectively improve the instrument resolution; high density detection unit is unique, so that it has a small
particle testing ability strong, high density detection unit using it with full range of seamless super capacity test the.
* Anti dry ultrasound: ultrasonic anti-dry function can be realized to avoid damage to the ultrasonic in the absence of water.
* Dust proof and shockproof design.
* Sample residue-free design and bubble-free design.
* Misoperation protection: The instrument has a self-protection function for misoperation, and the instrument does not respond to misoperation.
* Dry Wet Switching: one button automatic switching of software.(BPSA-6100D)
Model | BPSA-6100D | BPSA-5200H | ||
Test Aange | wet process: 0.01μm -1250μm | dry process: 0.1μm -1250μm | 0.1μm -800μm | |
Test Speed | <1min/ times (excluding sample dispersion time) | |||
Number of D etector Channels | wet process: 112 | dry process: 102 | 86 | |
Accuracy Error | dry process: <1%,wet process: <1% (D50 value of national standard sample) | <1%(D50 value of national standard sample) | ||
Repeatability Error | dry process: <1%, wet process: <0.5% (D50 value of national standard sample) | <0.5%(D50 value of national standard sample) | ||
Wet Process | Ultrasonic | Frequency: f=40KHz, power: p=80W, time: optional, adjustable, with ultrasonic anti drying | ||
Cycle and Stir | Integrated design of circular mixing, speed: 100-3950rpm, adjustable speed | Integrated design of circular mixing, speed: 10-3000rpm, adjustable speed | ||
Circulating Flow | Rated flow: 0-10L/min adjustable rated power: 25W | |||
Sample Cell | The design of boiling type sample pool, the dispersion effect is better, capacity: 190-600mL can be normal test | |||
Shading Detection | The instrument has a unique real-time detection function of the shade, to ensure that the amount of samples added more accurate | |||
Dry Process | Dispersion Mode | High pressure air dispersion | / | |
Feeding Method | Mechanical stepless speed regulation, vibration feeding, software control | |||
Oil Free Mute Air Compressor | With dust filtering function to ensure the accuracy of the test | |||
Cold Dryer | The freeze drier can filter the moisture in the air and guarantee the dispersing effect | |||
Power | AC220V±10%, 50/60Hz(Standard) AC110±10%, 60Hz(Optional) | |||
Package Size(mm) | 1270*410*620 710*430*440 390*390*560 350*340*410 750*420*700 800*550*800 | 680*510*530 | ||
Gross Weight(kg) | 198kg | 51kg |
Biochemical analyzer | Biosafety Cabinet | pH meter |
Hematology Analyzer | Laminar Flow Cabinet | Mixer, Shaker, Stirrer |
Electrolyte Analyzer | Fume hood | Water Bath |
Urine Analyzer | Autoclave | Spectrochemometer |
Elisa | Refrigerator | Balance |
POCT | Centrifuge | Hospital bed |
CLIA | Incubator & Oven | Wheelchair |
PCR | Tube/Tips/Reagent | Microscope |