Blue Jay Arc Fault Detection Busbar Feeder Protection Relay Arc Flash Relay for Voltage and Medium-Voltage Switchgear

Price $3500.00 Compare
Min Order 1 Piece
Shipping From Chongqing, China
Popularity 364 people viewed
Quantity
+-
 

Chongqing Blue Jay Technology Co., Ltd

VIP   Audited Supplier 2 years
Profile Certified by SGS/BV
AFR-M
Electromagnetic Relay
Household Appliances Relay, Communication Relay
3
Ac
3
Medium Power Relay
Open Relay
Electromagnetic Type
Miniature
Electric Parameter Relay
Low Power
Arc Surge Protective Device
Sealed
Digital Only
0.5
5-95%
Blue Jay
Carton
10*10cm
China
Product Description
AFR-M Arc protection relays are mainly used to detect arc faults in electrical systems and protect equipment and personnel in electrical systems from arc faults. Our arc protection relays can detect arcs by monitoring parameters such as current, voltage, and electric power, and quickly disconnect the power supply before an electrical fire occurs, thereby reducing the risk of fire.
 
Arc protection relays are usually used in medium and high-voltage power distribution systems, control cabinets, transformers, generators, motors and other electrical equipment. They adopt the dual-criteria principle of arc light detection and overcurrent detection and have the characteristics of fast protection action and high reliability.
 

Overview arc flash relay
Complete digital design, simple principle; 
Strong electrical performance;
Comprehensive record of fault information; Double criterion of over-current and arc, high reliability;
Optical fiber transmits, strong electromagnetic interference resistance;
Programmable logic of trip exit; Fast exit tripping, short total fault clearing time.

Feature

High-Speed Tripping for arc flash protection
The AFR-M arc flash protection relay provide a total trip time of less than 10ms for busbar faults and circuit breaker failure protection. Thus, it can send a trip signal to the circuit breaker as fast as possible.
Busbar Arc Flash Protection
Busbar arc flash is most likely to occur in busbar room, circuit breaker room, cable room and busbar cabinet, where insulators, conductor connections, switchgear, cable joints and other locations are potential arc flash sources. The AFR-M Arc flash protection relay is designed to monitor the busbar sections within a power system for potential arc fault occurrences. This advanced arc flash relay can monitor up to 48 busbar sections in single-phase, three-phase, or distributed configuration.
RS48 and Ethernet Communication
The AFR-M arc flash relay are with 2 RS485 ports and 2 Ethernet ports that support IEC60870-5-103 communication. It communicates via Modbus TCP, DNP3 LAN/WAN, Telnet, FTP, or IEC 61850 too. Moreover, You also can customize extra monitoring functions by RS485 connection, including Bus temperature monitoring (wireless), Partial Discharge monitoring sensor (TEV), and smoke sensor
Current & Light Sensing for Arc Flash Detection
The current sensing of AFR-M is through four 3-phase current signal input, monitoring 3 group of current for the phase and ground instantaneous overcurrent elements. Lighting sensing is through arc flash sensors including point sensor or fiber loop sensors. Or lighting sensing by pressure sensor. with 3 arc flash expansion modules option, the AFR-M arc flash protection system supports up to 48 arc flash sensor connection. Each arc flash expansion module support 12 arc flash sensors connection. The combination of light and current detection provides the ideal solution for arc-flash mitigation.
 

Specification

-. Power supply

   AC/DC85 ~ 265V

-. Consumption

   ≤ 8W

-. Current input

Current rated :5A/1A
Measurement range:protection current: 0~20In
Consumption:≤ 5VA

-. Electrical parameters tolerance
Protection current:≤ 2%
Protection frequency:0.1Hz

-. Arc signal input
Channels number:12-48 channels (optional)
Sensor type:Optical fiber
Detect light type:Visible light/UV light (optional)

-. Relay output
Channels number:9 channels
Operating Voltage:AC250V/8A
Input method:Passive contact
Isolation method:Photoelectric isolation, isolation voltage 2500V
Relay action cycle:<4ms

-. Digital input
Channels number:16 channels
Operating Voltage:220Vdc
Input method:Wet contact
Isolation method:Photoelectric isolation, isolation voltage 2500V
  
Note: Optional passive node (confirm before order)


-. Action time tolerance

Pure arc protection: ≤10ms
Double criterion protection: ≤20ms

-. RS485 communication
Interface:RS485 (one standard, two optional)
Isolation type:photoelectric isolation, lightning protection
Baud rate:9600bps
Protocol:Modbus
-. Ethernet communication
Interface:2-Way Ethernet optional
Network parameters:10M/100M adaptive
Default IP:192.168.12.2/192.168.13.2
Standard:IEC60870-5-103
-. Electromagnetic compatibility
ItemStandard
Electrostatic discharge test:IEC 60255-22-2:2008. level-4
Fast transient dry resistance test:IEC 60255-22-4:2008. level-A
1mhz burst interference test:IEC 60255-22-1-2007. level-3
Electrical disturbance test:IEC 60255-22-2:2008.level-3
Surge immunity test:IEC 60255-22-5:2008

Selectable models
ModelsAFR-M12AFR-M24AFR-M36AFR-M48
Basic parameter of arc flash relays
Power supply5~265Vac/dc, optional 48Vdc
ConsumptionMonitoring Stanby <8W
DO trig <10W
Rated current (In)5A or 1A
Protection range0~20 In
Burden0.5VA
Protect current accuracy<2%
Protect frequency accuracy0.1Hz
Arc signal & control
Sensor typelens point fiber optic sensors(1) or bare fiber optic sensors(2)
Arc sensor access channels12243648
DO relay channels4499
Trip coil contactAC250V/8A fast relay, passive node
Trip operation time<10ms @ only arc protection
<20ms @ overcurrent + arc protection
Safety isolation2500V isolation capacity
Binary inputs12121616
Others
Comm port1*  RS485 MODBUS-RTU
1* 10/100M Adaptive
Default 192.168.12.2/192.168.13.2
IEC-60870-5-103
SOE record512512512512
Waveform capture8888
Optional modulesWireless joints temperature monitor
Smoke detector

Application

Generally, the AFR-M arc flash protection relay is widely used in commercial and institutional electrical systems such as generation and Distribution networks, and industrial applications such as offshore, marine, mining, railway, etc.

Specifically, it is used in low-voltage or medium-voltage switchgear, solar combiner boxes, Industrial UPS, Junction boxes compact cabinets such as combiner boxes and inverters boxes, OEM panels with little available space, transformer compartments, generator control panels, or motor control center bucket.

Company Profile


 

Certifications


Our Service


FAQ



Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA