JLT-50(L/UL)
Counter Flow
Mechanical Ventilation
FRP
Wet
Open
Round
Ultra Low
Air Conditioning
ISO, CTI
New
C.S + HDG
FRP
FRP
ABS
C.S + HDG
ABS
ABS
JINLING
Export Standard Packing
JLT-50
China
8419500090
Product Description
JLT Series Counter Flow Round Cooling Tower JLT-50L/UL
Primary Competitive Advantages:
1. Brand-name Parts
2. Guarantee/Warranty
3. Competitive Price
4. Excellent Features
5. Superior Performance
6. Prompt Delivery
7. Quality Approvals
8. Well-deserved Reputation
9. High-Class Service
10. Small Orders Accepted
11. ISO9001 Quality System Certification
12. ISO14001 Environment System Certification
Skey Specifications/Special Feature:
1. Materials: FRP panels, HDG framework and PVC infill
2. With low noise model or super low noise
3. Used all over the world
JLT Series Customer Option
1. Automatic Oilling Device
2. Independent R&D Reducer
Delivery Details:
1. FOB Port: Ningbo or Shanghai
2. Lead Time: 20-35 days.



Primary Competitive Advantages:
1. Brand-name Parts
2. Guarantee/Warranty
3. Competitive Price
4. Excellent Features
5. Superior Performance
6. Prompt Delivery
7. Quality Approvals
8. Well-deserved Reputation
9. High-Class Service
10. Small Orders Accepted
11. ISO9001 Quality System Certification
12. ISO14001 Environment System Certification
Skey Specifications/Special Feature:
1. Materials: FRP panels, HDG framework and PVC infill
2. With low noise model or super low noise
3. Used all over the world
JLT Series Customer Option
1. Automatic Oilling Device
2. Independent R&D Reducer
Delivery Details:
1. FOB Port: Ningbo or Shanghai
2. Lead Time: 20-35 days.



Performance Index for JLT Series(3-1000L/UL) Counter Flow Round Cooling Tower | |||||||||||||||||||
Model | Water Flow M3/H | Head Load Pressure-(X10000Pa) | Overall Dimensions(MM) | Pipe Connection(DN:mm) | Exhaulst Fan | Weight(KG) | |||||||||||||
Standard | Low-Noise | Super Low-Noise | Inlet Pipe | Outlet Pipe | Overflow Pipe | Drain Pipe | Make up Pipe | Diateter(MM) | KWXSets | Stand | Low-noise | Super Low-noise | |||||||
JLT-3 | 3 | 1 | 700 | 1130 | 1040 | 1580 | 25 | 25 | / | 15 | 15 | 400 | 0.18 | 38 | 58 | 42 | 63 | 53 | 75 |
JLT-6 | 6 | 1.2 | 920 | 1460 | 1245 | 2100 | 40 | 40 | 25 | 25 | 15 | 584 | 0.18 | 54 | 130 | 57 | 136 | 72 | 151 |
JLT-8 | 8 | 1.3 | 920 | 1460 | 1245 | 2100 | 40 | 40 | 25 | 25 | 15 | 584 | 0.18 | 60 | 135 | 63 | 141 | 78 | 157 |
JLT-10 | 10 | 1.4 | 1020 | 1705 | 1380 | 2345 | 50 | 50 | 25 | 25 | 15 | 584 | 0.18 | 75 | 195 | 78 | 202 | 97 | 217 |
JLT-12 | 12 | 1.4 | 1380 | 1605 | 1710 | 2370 | 50 | 50 | 25 | 25 | 15 | 760 | 0.37 | 82 | 259 | 87 | 266 | 122 | 301 |
JLT-16 | 16 | 1.6 | 1380 | 1825 | 1710 | 2520 | 50 | 50 | 25 | 25 | 15 | 760 | 0.37 | 94 | 309 | 99 | 313 | 134 | 348 |
JLT-20 | 20 | 1.7 | 1380 | 2050 | 1710 | 2745 | 50 | 50 | 25 | 25 | 15 | 760 | 0.37 | 113 | 327 | 120 | 334 | 155 | 369 |
JLT-25 | 25 | 1.7 | 1600 | 1900 | 2035 | 2700 | 80 | 80 | 25 | 25 | 15 | 884 | 0.75 | 144 | 447 | 150 | 453 | 185 | 498 |
JLT-30 | 30 | 1.7 | 1800 | 2075 | 2130 | 2875 | 80 | 80 | 25 | 25 | 15 | 884 | 0.75 | 185 | 666 | 198 | 680 | 243 | 725 |
JLT-40 | 40 | 1.8 | 1800 | 2295 | 2130 | 3095 | 80 | 80 | 25 | 25 | 15 | 884 | 1.1 | 257 | 730 | 270 | 743 | 315 | 788 |
JLT-50 | 50 | 1.8 | 2100 | 2260 | 2520 | 3275 | 100 | 100 | 40 | 40 | 20 | 1184 | 1.1 | 423 | 753 | 433 | 768 | 493 | 823 |
JLT-60 | 60 | 1.9 | 2100 | 2490 | 2520 | 3505 | 100 | 100 | 40 | 40 | 20 | 1184 | 1.5 | 521 | 913 | 531 | 923 | 611 | 1003 |
JLT-70 | 70 | 2.3 | 2600 | 3010 | 3040 | 4180 | 100 | 100 | 40 | 40 | 20 | 1470 | 2.2 | 567 | 983 | 578 | 994 | 658 | 1074 |
JLT-80 | 80 | 2.4 | 2600 | 3250 | 3040 | 4420 | 100 | 100 | 40 | 40 | 20 | 1470 | 2.2 | 607 | 1023 | 618 | 1034 | 698 | 1114 |
JLT-90 | 90 | 2.5 | 2890 | 3250 | 3290 | 4420 | 100 | 100 | 40 | 40 | 20 | 1470 | 2.2 | 660 | 1090 | 675 | 1095 | 755 | 1190 |
JLT-100 | 100 | 2.6 | 2890 | 3490 | 3290 | 4650 | 100 | 100 | 40 | 40 | 20 | 1470 | 2.2 | 713 | 1148 | 724 | 1159 | 804 | 1239 |
JLT-125 | 125 | 2.8 | 3300 | 3250 | 3770 | 4505 | 125 | 125 | 40 | 40 | 20 | 1780 | 4 | 908 | 1588 | 925 | 1605 | 1025 | 1705 |
JLT-150 | 150 | 3 | 3300 | 3475 | 3770 | 4735 | 150 | 150 | 80 | 50 | 25 | 1780 | 4 | 1015 | 2035 | 1032 | 2052 | 1132 | 2152 |
JLT-175 | 175 | 3 | 3960 | 3710 | 4630 | 4910 | 150 | 150 | 80 | 50 | 25 | 2370 | 5.5 | 1613 | 3317 | 1643 | 3338 | 1784 | 3488 |
JLT-200 | 200 | 3.3 | 3960 | 3930 | 4630 | 5130 | 200 | 200 | 80 | 50 | 25 | 2370 | 5.5 | 1796 | 3465 | 1817 | 3486 | 1967 | 3636 |
JLT-225 | 225 | 3.5 | 4400 | 4100 | 5100 | 5300 | 200 | 80 | 50 | 25 | 50 | 2400 | 5.5 | 1810 | 3514 | 1932 | 3636 | 2082 | 3786 |
JLT-250 | 250 | 3.8 | 4400 | 4400 | 5100 | 5630 | 200 | 80 | 50 | 25 | 50 | 2400 | 7.5 | 2280 | 4082 | 2315 | 4117 | 2495 | 4297 |
JLT-300 | 300 | 4 | 5320 | 4640 | 6200 | 6040 | 250 | 250 | 100 | 80 | 50 | 3000 | 7.5 | 2420 | 6101 | 2457 | 6138 | 2637 | 6318 |
JLT-350 | 350 | 4.2 | 5320 | 4870 | 6200 | 6270 | 250 | 250 | 100 | 80 | 50 | 3000 | 11 | 2530 | 6475 | 2571 | 6516 | 2751 | 6696 |
JLT-400 | 400 | 4.5 | 6000 | 5050 | 7000 | 6550 | 250 | 250 | 100 | 80 | 50 | 3400 | 11 | 3153 | 8185 | 3206 | 9238 | 3601 | 8633 |
JLT-450 | 450 | 4.7 | 6000 | 5280 | 7000 | 6780 | 250 | 250 | 100 | 80 | 50 | 3400 | 15 | 3347 | 9332 | 3401 | 9386 | 3819 | 9904 |
JLT-500 | 500 | 5 | 6840 | 5350 | 8040 | 6950 | 250 | 250 | 100 | 80 | 50 | 3700 | 15 | 3860 | 10970 | 3980 | 11090 | 4200 | 11300 |
JLT-600 | 600 | 5.2 | 6840 | 5570 | 8040 | 7170 | 250 | 250 | 100 | 80 | 50 | 3700 | 18.5 | 4084 | 11670 | 4143 | 11786 | 4863 | 11958 |
JLT-700 | 700 | 5.2 | 7960 | 5830 | 9160 | 7630 | 300 | 300 | 100 | 80 | 50 | 4200 | 22 | 5460 | 13250 | 5580 | 13376 | 5680 | 13676 |
JLT-800 | 800 | 5.4 | 7960 | 6050 | 9160 | 7850 | 300 | 100 | 80 | 50 | 50 | 4200 | 22 | 5780 | 13570 | 5900 | 13696 | 6000 | 13796 |
JLT-1000 | 1000 | 5.8 | 8880 | 6390 | 1000 | 8500 | 350 | 350 | 125 | 80 | 50 | 5000 | 30 | 7315 | 15110 | 7450 | 15245 | 7570 | 15365 |
Design Conditions:Water Inlet Temp.-T1=37ºC,Water Out Temp.-T2=32ºC,-WBT=28ºC, RangeΔTS=5ºC Barometric-P=99400Pa. | |||||||||||||||||||
Remark:The cooling tower can be made-to-measure according to customer`s design conditions and special requirements. | |||||||||||||||||||
Explanation Model :JN:Cross Flow Rectangular Cooling Tower; L:Low Noise; |