WOZB-YJY
Construction, Overhead, Underground, Industrial, Power Station, Telecommunication, Computer
Low and Medium Voltage Cable
DC & AC
PVC
PVC
Round Wire
Bare Copper Wire
ISO, CCC, CE
Wozb-Yjy
Huacheng
Huangcheng Brand
Normal Package
0.6/1KW 3*95+1*50
China-Mainland
8544492100
Product Description
BTLY PVC Teck90 Electrical Power Copper Aluminium Wire Industrial Flexible Cable armor Teck 600V
14AWG-1000KCMIL 3C Teck90 cable
Black ,red, blue for 3 conductors;
Black, red, blue, white for 4 conductors.
Application:
Suitable for use in exposed or concealed wiring in dry or wet locations, in
ventilated or ladder type cable trays in dry or wet conditions, on walls or beams, or directly buried.
Suitable for use in hazardous locations: Class I - Groups A, B, C and D, Class II - Groups E, F and G, Class III - All Groups
Standard: CSA C22.2 No. 131, Type TECK90 cable;
CSA C22.2 No. 38, Thermoset insulated wires and cables (Type RW90)
FT4 - Flame Test (70,000 BTU/Hr - Vertical Tray Flame Test)
Working temperature: -40ºC to +90ºC
Voltage: 600V




Product Description
14AWG-1000KCMIL 3C Teck90 cable
- Conductor: annealed bare copper wires, or compact aluminum 8000 series wires, class B.
- Insulation: Cross-linked Polyethylene (XLPE) Type RW90
Black ,red, blue for 3 conductors;
Black, red, blue, white for 4 conductors.
- Bonding conductor: annealed bare copper wires, or compact aluminum 8000 series wires, class B.
- Inner Jacket: Flame-retardant and moisture resistant Polyvinyl Chloride (PVC)
- Armour: Aluminum Interlock Armour (AIA);
- Outer-jacket: Low-temperature, moisture and sunlight resistant Polyvinyl Chloride (PVC), black
Application:
Suitable for use in exposed or concealed wiring in dry or wet locations, in
ventilated or ladder type cable trays in dry or wet conditions, on walls or beams, or directly buried.
Suitable for use in hazardous locations: Class I - Groups A, B, C and D, Class II - Groups E, F and G, Class III - All Groups
Standard: CSA C22.2 No. 131, Type TECK90 cable;
CSA C22.2 No. 38, Thermoset insulated wires and cables (Type RW90)
FT4 - Flame Test (70,000 BTU/Hr - Vertical Tray Flame Test)
Working temperature: -40ºC to +90ºC
Voltage: 600V



Phase Conductor | Bonding Conductor | Phase conductor single wire numbers | Nominal thickness of XLPE insulation | Approx. diameter after assembly | Nominal thickness of inner sheath | Approx. Diameter armoured | Nominal thickness of outer sheath | Approx. O.D. of cable | |
Core | AWG or Kcmil | AWG or Kcmil | Nos. | mm | mm | mm | mm | mm | mm |
3 | 14 | 14 | 7 | 0.76 | 7.3 | 1.14 | 14.7 | 1 | 17 |
3 | 12 | 14 | 7 | 0.76 | 8.3 | 1.14 | 15.7 | 1 | 18 |
3 | 10 | 12 | 7 | 0.76 | 9.7 | 1.14 | 17 | 1 | 19 |
3 | 8 | 10 | 7 | 1.14 | 12.3 | 1.52 | 20.4 | 1 | 22 |
3 | 6 | 8 | 7 | 1.14 | 14.2 | 1.52 | 22.3 | 1 | 24 |
3 | 4 | 8 | 7 | 1.14 | 16.6 | 1.52 | 24.8 | 1 | 27 |
3 | 3 | 6 | 7 | 1.14 | 17.9 | 2.03 | 27.1 | 1 | 29 |
3 | 2 | 6 | 7 | 1.14 | 19.6 | 2.03 | 28.8 | 1 | 31 |
3 | 1 | 6 | 19 | 1.4 | 22.4 | 2.03 | 31.6 | 1 | 34 |
3 | 1/0 | 6 | 19 | 1.4 | 24.5 | 2.03 | 33.6 | 1 | 36 |
3 | 2/0 | 6 | 19 | 1.4 | 26.7 | 2.03 | 35.8 | 1 | 38 |
3 | 3/0 | 4 | 19 | 1.4 | 29.2 | 2.03 | 38.4 | 1.2 | 41 |
3 | 4/0 | 4 | 19 | 1.4 | 32.1 | 2.03 | 41.3 | 1.2 | 44 |
3 | 250 | 4 | 37 | 1.65 | 35.7 | 2.03 | 44.8 | 1.2 | 47 |
3 | 300 | 4 | 37 | 1.65 | 38.4 | 2.79 | 49.1 | 1.2 | 51 |
3 | 350 | 3 | 37 | 1.65 | 40.9 | 2.79 | 51.6 | 1.2 | 54 |
3 | 400 | 3 | 37 | 1.65 | 43.3 | 2.79 | 54 | 1.2 | 56 |
3 | 450 | 3 | 37 | 1.65 | 45.5 | 2.79 | 56.2 | 1.2 | 59 |
3 | 500 | 3 | 37 | 1.65 | 47.5 | 2.79 | 58.2 | 1.5 | 61 |
3 | 550 | 3 | 37 | 2.03 | 51.3 | 2.79 | 62 | 1.5 | 65 |
3 | 600 | 2 | 61 | 2.03 | 53.4 | 2.79 | 64.1 | 1.5 | 67 |
3 | 650 | 2 | 61 | 2.03 | 55.1 | 2.79 | 65.8 | 1.5 | 69 |
3 | 700 | 2 | 61 | 2.03 | 56.9 | 2.79 | 67.6 | 1.5 | 71 |
3 | 750 | 2 | 61 | 2.03 | 58.6 | 2.79 | 69.3 | 1.5 | 72 |