BW-G (I) BP
Boosting Water Supply
380V×(100±10%), Three - Phase Five -
+4°c to +40°c (Corresponding Measures Must
20% - 90% (No Condensation at 20°c)
a Place Without Conductive Dust, Gases That Can C
EAST
Standard Export Plywood Case or Carton
1000mmx840mmx2000mm
Product Description
Product Overview
With the development and progress of social, economic, and technological conditions, and the gradual improvement of people's living standards, water supply safety has received increasing attention. After years of design and research and development, Shanghai Dongfang Pump Industry (Group) has successfully developed a safe and efficient water supply unit with intelligent, information - based, and standardized features. By comprehensively utilizing information technologies such as the Internet of Things, wired sensing or virtual sensing, and AR (Augmented Reality), it effectively integrates a series of systems, including intelligent perception of the operating status of the water supply unit, intelligent data collection and transmission, system alarm linkage, and intelligent diagnosis of unit faults. This enhances the safety management level and efficient operation status of water supply equipment, and achieves dynamic perception, intelligent assessment, and safety protection, providing users with systematic solutions throughout the product's entire life cycle.
With the development and progress of social, economic, and technological conditions, and the gradual improvement of people's living standards, water supply safety has received increasing attention. After years of design and research and development, Shanghai Dongfang Pump Industry (Group) has successfully developed a safe and efficient water supply unit with intelligent, information - based, and standardized features. By comprehensively utilizing information technologies such as the Internet of Things, wired sensing or virtual sensing, and AR (Augmented Reality), it effectively integrates a series of systems, including intelligent perception of the operating status of the water supply unit, intelligent data collection and transmission, system alarm linkage, and intelligent diagnosis of unit faults. This enhances the safety management level and efficient operation status of water supply equipment, and achieves dynamic perception, intelligent assessment, and safety protection, providing users with systematic solutions throughout the product's entire life cycle.
Working Environment
- Power supply voltage: 380V×(100±10%), three - phase five - wire system;
- Ambient temperature: +4°C to +40°C (corresponding measures must be taken if it exceeds this range);
- Relative air humidity: 20% - 90% (no condensation at 20°C);
- Installation location: A place without conductive dust, gases that can corrode metals and damage insulation, and free from explosion hazards;
- Altitude not exceeding 1000m. When it exceeds, the control components should be adjusted accordingly.
Scope of Application
- The pressurized water supply equipment is widely applicable to water supply in buildings with good municipal conditions;
- Applicable to residential communities, public buildings, schools, hospitals, factories, renovation of old pump houses, etc.

Description of Working Principle

Serial Number | Accessory Name | Serial Number | Accessory Name | Serial Number | Accessory Name | Serial Number | Accessory Name |
---|---|---|---|---|---|---|---|
1 | Control Cabinet | 2 | Bidirectional Compensation Switching Device | 3 | Bidirectional Compensation Tank | 4 | Digital Vacuum Suppressor |
5 | Steady Flow Tank | 9 | Butterfly Valve | 10 | Check Valve | 11 | Water Pump (Optional Integrated High - efficiency Synchronous Motor) |
12 | Pressure Sensor | 13 | Overpressure Protection | Small Flow Pressure - maintaining Tank | |||
Optional Accessories (Except for UV Disinfector): Customers should install them reasonably according to the actual installation location of the equipment and the pump room (Installation accessories are not provided). | |||||||
6 | UV Disinfector (Optional, Installed by the Manufacturer) | 7 | Backflow Preventer (Optional, Installed by Customers) | 8 | Filter (Optional, Installed by Customers) |
- The BW - G(III) water supply equipment utilizes the existing pressure of the municipal pipe network to supply water with superimposed pressure without affecting surrounding users (supplying water in proportion to the inflow), achieving energy - saving. The water from the municipal pipe network is directly connected to the inlet of the equipment, and the outlet of the equipment is linked to the user's pipe network. The entire system is isolated from the outside. Meanwhile, the equipment meets performance standards, maintains a constant water supply pressure, runs stably without leakage, thus conserving water resources and ensuring the absolute safety and pollution - free nature of users' water supply.
- The equipment mainly consists of a bidirectional compensation tank, a pneumatic tank, a disinfection device (optional), a pressurized water pump unit, a bidirectional compensation mechanism, a pressure - stabilizing system, a digital full - variable - frequency control system, and inlet and outlet water pressure detection.
- During low - water - consumption periods, when the water supply and pressure from the municipal pipe network fully meet the requirements of the user's pipe network, the control system puts the water pumps into a sleep energy - saving state or a short - term low - speed operation state for a single pump to replenish pressure. The bidirectional compensation tank can maintain pressure for small - flow water supply.
- During high - water - consumption periods, when the pressure of the municipal pipe network is insufficient but the water supply can meet users' needs, the pressure of the pipe network is directly superimposed on the inlet of the water pumps. The control system adjusts the rotational speed of the water pumps and the number of pumps in operation according to users' water consumption. The bidirectional compensation tank briefly supplements the insufficient water supply in the pipe network to ensure a constant - pressure water supply to users.
- When users' water demand increases, causing the water supply in the pipe network to be less than the demand, and the inlet water pressure is lower than the set value, or there is an instantaneous pressure fluctuation, the bidirectional compensation tank automatically compensates for the municipal inlet water through the bidirectional compensator. Meanwhile, the control system monitors the inlet water pressure of the pipe network in real - time. Through computer calculus and fuzzy control, it promptly reduces the rotational speed of the water pumps and controls the water supply flow to ensure that the water supply equipment does not create negative pressure suction on the municipal pipe network and does not stop supplying water due to insufficient water supply.
- As the pressure of the municipal pipe network gradually drops to the pre - set protection pressure value, the microcomputer control system also gradually reduces the rotational speed of the water pumps until the system automatically stops operating. When the pressure of the municipal pipe network recovers to an allowable level, the equipment automatically resumes operation.
Product FeaturesEnsuring Safe and Hygienic Water Supply
| ![]() |


Ensure Stable Water Supply Pressure
| ![]() |
Ensure Stable Product Quality
The pictures show various manufacturing equipment and components.
- Flexible manufacturing is carried out using robots and numerically - controlled equipment, which surpasses traditional welding, cutting, and bending techniques, ensuring the reliability and stability of product quality.
Production Plant

Main Processing Equipment


Electrophoresis and coating line

Company Profile

