BW-Z(II)
Boosting Water Supply
≤ 100m³/H
≤ 1.6MPa
≤ 11kw
2 to 3 Units (Including One Standby Pump)
≤ 0.01MPa
- 40ºC to 55ºC
20% to 90% (for The Electrical Control Part)
Three - Phase Five - Wire System (Tn - S), AC380
≤ 1000m
No Flammable, Explosive, Corrosive Substances, and
EAST
Standard Export Plywood Case or Carton
1150mmx1150mmx2100mm
Product Description
Direct-connected Water Supply Equipment
Product Overview
The direct-connected water supply equipment is a new type of water supply equipment developed and manufactured by Shanghai Dongfang Pump Industry (Group) Co., Ltd. Adhering to the concepts of technology, environmental protection, energy conservation, and safety, and featuring specialization, refinement, distinctiveness, and innovation, it makes full use of new-generation information technologies such as big data, artificial intelligence, cloud computing, and edge computing. Relying on strong production capabilities, this equipment has remarkable characteristics including high integration, energy conservation and environmental protection, excellent performance, compact structure, and quick installation.
Application Fields
- Pressure boosting for high-rise and multi-storey buildings
- Residential areas with insufficient pressure at the end of the water supply network
- Improving the quality and efficiency of rural drinking water
- Residential areas with old pumping stations undergoing renovation
- Residential areas without pumping stations
- Water supply in scenic areas
- Emergency temporary water supply
Product Features
- Protection Assurance
- The enclosure is made of SUS304 material with a P - shaped rain - proof and sun - proof design (IP55). The exterior is designed with a service life of 50 years.
- Safety and Hygiene
- The food - grade stainless - steel flow - through body operates in a fully - enclosed manner, completely eliminating secondary pollution.
- Energy Conservation and Environmental Protection
- Using pressure - boosting technology with water - squeezing, full - variable control, it makes full use of the pressure in the municipal water supply network, is equipped with air - squeezing pressure, and reduces pressure for small - flow, thus lowering energy consumption.
- Convenient Operation
- One - button start and stop, with a transparent view of the working status. It is designed based on ergonomics, with a compact structure and an aesthetically pleasing exterior.
- Unattended Operation
- Automatic pump switching, balanced operation, automatic inspection, stop when there is no water, and automatic restart when power is restored.
- Intelligent Security
- Remote monitoring, temperature and humidity adjustment, water leakage detection, noise detection, and fault alarm.
- Quick Installation
- Modular detachable structure, pre - fabricated in the factory and delivered as a whole. Just connect the inlet and outlet water pipes and power on to operate.
- Noise Reduction
- Three - layer noise reduction with sound - absorbing panels, integral sound - absorbing covers, and stainless - steel exteriors, which is 10dB or more lower than conventional products.
- Reliable Service
- The company has 16 subsidiaries, 26 branch offices, over 200 business offices, and provides 7×24 - hour after - sales service. The one - time commissioning qualification rate is ≥98%.

Application Conditions
- Water supply flow rate: ≤ 100 cubic meters per hour
- Water supply pressure: ≤ 1.6 megapascals
- Single - pump power: ≤ 11 kilowatts
- Number of water pumps: 2 to 3 units (including one standby pump)
- Control accuracy: ≤ 0.01 megapascals
- Ambient temperature: - 40ºC to 55ºC
- Relative humidity: 20% to 90% (for the electrical control part)
- Power supply: Three - phase five - wire system (TN - S), AC380V ± 20V, 50Hz
- Altitude: ≤ 1000 meters
- Environmental quality: Free of flammable, explosive, corrosive substances, and conductive dust
Model Definition
BW - Z(II)
- Component Configuration:
- A.A: Imported components. : Number of frequency converters.
- B.B: Domestic components. : Number of frequency converters.
- Other Option Requirements:
- No mark: Standard configuration with no additional requirements.
- D: Electric heating.
- K: Industrial air - conditioning.
- Pump Series:
- No mark: DFCL series.
- T: Other pump types.
- Number of Water Pumps: 2 - 3 (including 1 standby pump).
- Single - pump Power (kW):
- Equipment Head (m):
- Equipment Flow Rate (m³/h):
- Direct - connected type:
- Pipe network superposition (non - negative pressure) water supply equipment:
Example: BW - Z(II)32/58-5.5-3-A3 indicates a direct - connected water supply equipment with an equipment flow rate of 32 m³/h, an equipment head of 58 m, 3 DFCL water pumps, a single - pump power of 5.5 kW, imported main components, and full - frequency conversion control.
Working principle

Working principle

Serial Number | Name | Serial Number | Name | Serial Number | Name | Serial Number | Name |
---|---|---|---|---|---|---|---|
1 | Butterfly valve | 2 | Flexible rubber joint | 3 | Water pump | 4 | Check valve |
5 | Pressure transmitter | 6 | Electric contact pressure gauge | 7 | Control cabinet | 8 | Air pressure tank |
9 | Lighting lamp | 10 | Temperature and humidity sensor (Optional) | 11 | Water immersion sensor (Optional) | 12 | Smoke sensor (Optional) |
13 | Noise sensor (Optional) | 14 | Industrial air conditioner (Optional) | 15 | Flowmeter (Optional, installed outside the box) | 16 | Filter (Optional, installed outside the box) |
17 | Exhaust valve |
Function Configuration Table
Serial Number | Category | Name | Function Description |
---|---|---|---|
1 | Enclosure | Outdoor - type enclosure | Two materials are available, SUS304 and spray - plastic carbon steel. Outdoor - type design, wind - proof, rain - proof, and dust - proof. |
2 | Intelligent Control System | System protection module | Overload, short - circuit, and phase - loss protection, automatic inspection, fault alarm, etc. |
Pump group control module | Full - frequency conversion control, energy - saving and consumption - reducing, alternate operation, extending the equipment's service life. | ||
3 | Pump Group System | Water pump | Fully - enclosed air - cooled high - efficiency motor, smooth and reliable operation. Stainless - steel stamping and welding impeller, safe and hygienic. |
Inlet main pipe assembly | Food - grade stainless - steel flow - through parts, fully ensuring water quality and hygiene. | ||
Outlet main pipe assembly | |||
Complete set of valve group | SUS304 stainless - steel valve parts, corrosion - resistant, safe and hygienic. | ||
Air pressure tank | Stabilizes the outlet pressure of the equipment, maintains pressure for small - flow, and avoids frequent start - stop of the equipment. | ||
4 | HVAC System | Industrial air conditioner (Optional) | Heating, cooling, and dehumidifying functions, with an RS485 interface. |
Temperature and humidity acquisition module (Optional) | Collects temperature and humidity information. | ||
Ventilation system | Mechanical ventilation, renews air, cools down and dehumidifies. | ||
5 | Security System | Intelligent door lock (Optional) | Supports opening methods such as fingerprint, password, IC card, and mechanical key. |
Video monitoring | Enables real - time viewing of the surrounding environment. | ||
6 | Sensing System (Optional) | Water immersion detection module | Achieves early warning for equipment flooding and water leakage. |
Smoke sensing module | Comprehensively senses environmental parameters and conducts comprehensive analysis to ensure the safe operation of the equipment. | ||
Noise sensing module | |||
7 | Pipeline Measurement and Control System | Pressure detection module | Interacts to achieve water - shortage shutdown, over - pressure protection, and pipe - burst protection. |
Filter (Optional) | Protects water pumps and valves from wear and blockage. | ||
Flowmeter (Optional) | Measures the water volume conveyed by the equipment, used for energy - consumption analysis, leakage detection, etc. |