RayCure C18 (endcapped) sorbent is based on
ostadecyl silane-bonded silica, it is the most common silica-based reversed phase SPE cartridge. It can retain most of organic substances from aqueous phase system and is widely used in the field of environment and food safety.

Part number | Description |
RC-204-13802 | SPE cartridge:RayCure GCB,250mg/6mL,30/Pack |
RC-204-13804 | SPE cartridge:RayCure GCB,500mg/6mL,30/Pack |
RC-204-13806 | SPE cartridge:RayCure GCB,250mg/3mL,50/Pack |
RC-204-13807 | SPE cartridge:RayCure GCB,2000mg/12mL,20/Pack |
RC-204-68305 | SPE cartridge:RayCure GCB,1000mg/6mL,30/Pack |
RC-204-16861 | SPE cartridge:RayCure AL-A,100mg/1mL,100/Pack |
RC-204-16862 | SPE cartridge:RayCure AL-A,200mg/3mL,50/Pack |
RC-204-16863 | SPE cartridge:RayCure AL-A,500mg/3mL,50/Pack |
RC-204-16864 | SPE cartridge:RayCure AL-A,500mg/6mL,30/Pack |
RC-204-16865 | SPE cartridge:RayCure AL-A,1000mg/6mL,30/Pack |
RC-204-16866 | SPE cartridge:RayCure AL-A,2000mg/6mL,30/Pack |
RC-204-16867 | SPE cartridge:RayCure AL-A,60mg/3mL,50/Pack |
RC-204-16881 | SPE cartridge:RayCure AL-B,100mg/1mL,100/Pack |
RC-204-16882 | SPE cartridge:RayCure AL-B,200mg/3mL,50/Pack |
RC-204-16883 | SPE cartridge:RayCure AL-B,500mg/3mL,50/Pack |
RC-204-16884 | SPE cartridge:RayCure AL-B,500mg/6mL,30/Pack |
RC-204-16885 | SPE cartridge:RayCure AL-B,1000mg/6mL,30/Pack |
RC-204-16886 | SPE cartridge:RayCure AL-B,2000mg/6mL,30/Pack |
RC-204-16887 | SPE cartridge:RayCure AL-B,2000mg/12mL,20/Pack |
RC-204-16901 | SPE cartridge:RayCure AL-N,100mg/1mL,100/Pack |
RC-204-16902 | SPE cartridge:RayCure AL-N,200mg/3mL,50/Pack |
RC-204-16903 | SPE cartridge:RayCure AL-N,500mg/3mL,50/Pack |
RC-204-16904 | SPE cartridge:RayCure AL-N,500mg/6mL,30/Pack |
RC-204-16904N | SPE cartridge: RayCure AL-N,500mg/6mL,30/Pack,SPE-06D specific |
RC-204-16905 | SPE cartridge:RayCure AL-N,1000mg/6mL,30/Pack |
RC-204-16906 | SPE cartridge:RayCure AL-N,2000mg/6mL,30/Pack |
RC-204-16907 | SPE cartridge:RayCure AL-N,60mg/3ml,50/Pack |
RC-204-16908 | SPE cartridge:RayCure AL-N,1000mg/3mL,50/Pack |
RC-204-16909 | SPE cartridge:RayCure AL-N,20g/60ml,10/Pack |
RC-204-16941 | SPE cartridge:RayCure Florisil ,100mg/1mL,100/Pack |
RC-204-16942 | SPE cartridge:RayCure Florisil ,200mg/3mL,50/Pack |
RC-204-16943 | SPE cartridge:RayCure Florisil ,500mg/3mL,50/Pack |
RC-204-16944 | SPE cartridge:RayCure Florisil ,500mg/6mL,30/Pack |
RC-204-16945 | SPE cartridge:RayCure Florisil ,1g/6mL,60-100Mesh,30/Pack |
RC-204-16947 | SPE cartridge:RayCure Florisil ,500mg/12mL,20/Pack |
RC-204-16948 | SPE cartridge:RayCure Florisil ,1g/12mL,20/Pack |
RC-204-16949 | SPE cartridge:RayCure Florisil ,1g/6mL,100-200Mesh,30/Pack |
RC-204-68305 | SPE cartridge:RayCure GCB,1000mg/6mL,30/Pack |
RC-204-E4301 | SPE cartridge:RayCure Na2SO4,2g/6mL,30/Pack |
RC-204-E4301N | SPE cartridge:RayCure Na2SO4,2g/6mL,30/Pack,SPE-06D specific |
RC-204-E4302 | SPE cartridge:RayCure Na2SO4,1g/6mL,30/Pack |




HOW DOES SPE COLUMN WORK?
SPE is a conventional and efficient extraction technique, it uses the affinity of solutes dissolved or suspended in mobile phase for stationary phase to separate desired compounds from a mixture. And there are two solid phase extraction mechanisms to obtain target analytes from complex samples, to retain desired compounds in stationary phase or retain impurities in solid phase. Depending on the difference of two mechanisms, SPE procedures could be a bit various.
When sample portion passes through SPE column, undesired impurities are discarded with mobile phase, target compounds are retained in stationary phase, then rinse stationary phase with eluents to collect target compounds. It is the most commonly used purification mechanism of solid phase extraction.
In the opposite, to retain impurities in stationary phase, target compounds and few impurities are collected in mobile phase when sample portion passes through SPE column. Rinse the stationary phase which impurities is retained with solvents to obtain rest of retained target compounds. This mechanism is mostly used to eliminate fat-soluble impurities of ion analysis and analysis of multiple pesticides in fruits and vegetables.