CE Approved, Direct Bonded Copper Substrates Firing Furnace

Price $500000.00 Compare
Min Order 1 Set
Shipping From Anhui, China
Popularity 490 people viewed
Quantity
+-
 

Hengli Eletek Co., Ltd.

VIP   Audited Supplier 14 years
Profile Certified by SGS/BV
HSA series
12 Months
12 Months
Dbc Equipment
CE, ISO
Horizontal Type
Hengli
1160c
50kg/M2
400mm
36 Points
HENGLI
Wooden Box Iron Bracket
17500 * 1400 * 1800mm
China
8514390090
Product Description
HSA4007-1612ZNO Belt Atmosphere Firing Furnace
1. Typical application fields:
Typical application fieldsIt is mainly used for high temperature firing, oxidation, copper coating and other high temperature heat treatment in N2 or N2, O2 mixed atmosphere
2. Equipment specification and structure:
Belt Atmosphere Firing Furnace for Dbc / Dcb
Codenamelengthexplain
1Entrance
platform
900mmIncluding inlet gas collection hood
2Entrance transition section1320mmIncluding inlet air curtain and heating air inlet
3Heating zone4880mm16 temperature zone, each length is 305mm and the power is 12KW
4Free cooling section600mmFree cooling (heat preservation to prevent heat from spreading to the environment)
5Cooling section6500mmWater cooling
6Exit platform300mm 
7Exit transfer platform3000mmForced air cooling zone length is 1000mm
8Total length of equipment17500mm 
Furnace structureThe structure of large furnace chamber and muffle Inconel 601 are adopted. The muffle adopts corrugated muffle with thickness of 6 mm
Effective height70mm
Equipment weightAbout 8000kg
Dimensions17500 × 1400 × 1800mm (L × w × h), excluding foundation, chimney and indicator light
Appearance colorHanging board adopts high temperature spray, color is camel gray computer color, color label: RAL7035
     
3. Thermal system:
Rated temperature1130ºC
Maximum temperature1160ºC
Heating elementHeating module composed of ceramic rod wrapped with  heating wire
heating power230 kW, including each zone is 14 kW for 1-6 temperature zone and 14.3 kW for 7-16 temperature zone
(six filament areas in each temperature zone: top left 1.5KW, top middle 4.15kw, top right 1.5KW, bottom left 1.5KW, bottom middle 4.15kw,bottom right 1.5KW)
Heat preservation power of empty furnace≤80kW
Number of temperature zones16 zones
Temperature control points36 Points (1-6 temperature zone is controlled by single point; 7-16 temperature zone is controlled by 3 points in each temperature zone, and each temperature control point is output by 2 points in proportion)
ThermocoupleS-type thermocouple
Surface temperature rise<15ºC
Discharge temperature<50ºC
Temperature control stability±1ºC
Temperature uniformity± 2 ºC (constant temperature zone 1100 ºC)
4. Transmission system:
Belt width400mm
Wire diameter and threading2.5*3.0
Grid size10*15
Structural styleBalanced type
Belt materialCr20Ni80; grid 7 * 12, 2.2 * 2.8
Maximum load50kg / m2 (excluding belt weight)
Transmission modeFriction drive with large wrap angle
Speed range50~300 mm / min, variable frequency stepless speed regulation, digital display
Driving systemThe drive control adopts frequency converter to drive motor, which is controlled by reducer, and the speed is continuously adjustable
Conveyor structureThe belt conveyor is driven by chain wheel and chain to drive the driving and passive wheels. The belt is driven by the friction between the driving wheel and the belt. The belt rectifying device is installed on both sides of the entrance and exit
Cleaning method of mesh beltIntegrated dust removal with brush and bag
Ultrasonic cleaning machine (with drying function)
5. Atmosphere system:
 
 
Atmosphere control systemIncluding nitrogen gas pipe, mixed gas pipe, detection gas pipe, exhaust system
Nitrogen gas path:
AInlet air curtainNitrogen, 0-200L/min; divided into two channels, each flow switch control flow
BRubber discharge gas intakeNitrogen, 0-100L/min; flow control by flow switch
CGas intake of preheating sectionNitrogen and oxygen mixture (nitrogen is controlled by flow switch and air is controlled by mass flowmeter), 0-100L/min, after mixing, it is divided into two channels, and each channel is controlled by flow switch
EConstant temperature gas inletNitrogen and oxygen mixture (nitrogen is controlled by flow switch and air is controlled by mass flowmeter), 0-200L/min, after mixing, it is divided into four channels, and each channel is controlled by flow switch
FCooling gas intakeNitrogen, 0-200L/min; flow control by flow switch
GOutlet gas curtainNitrogen, 0-200L/min; divided into two channels, each flow switch control flow
Detection gas pipe: oxygen analyzer, switching through solenoid valve
Nitrogen and oxygen mixed gas source (2 points)Oxygen content ≤ 5ppm
Heating zoneOxygen content ≤ 15ppm + oxygen content of gas source
High temperature zone 1Oxygen content ≤ 10ppm + oxygen content of gas source
High temperature zone 2Oxygen content ≤ 10ppm + oxygen content of gas source
Cooling zoneOxygen content ≤ 15ppm + oxygen content of gas source
Exhaust systemThe inlet and outlet transition sleeves are respectively provided with one exhaust pipe
    
6. Cooling system:
Cooling structureWater cooling coil + double stainless steel cooling water jacket structure
Cooling modeInternal air cooling combined with external water cooling is adopted
Cooling test5-point water temperature detection of cooling water jacket
Furnace top cooling systemThere is a water-cooled coil tube cooling system on the top of the furnace heating section, which is used for external cooling of the equipment to reduce the surface temperature rise.
Inlet and return water systemUnder normal conditions, the circulating water system is used for the inlet and return water. When the circulating water fails, the inlet and return water are immediately switched to the urban water supply system
Alarm indicationLow water pressure alarm and over temperature alarm
7. Safety protection:
Belt stop buttonOne stop button is set at each end plate of the entrance and exit. After pressing the button, the belt stops running
Alarm indicationOvertemperature, frequency converter alarm, low pressure sound and light alarm
Safe heating rate of equipment≤3ºC/min
8. Temperature control system:
Temperature measurementEach control point is measured independently by S-type thermocouple
Control instrumentIt is controlled by intelligent regulator.With PID parameter self-tuning, high temperature upper limit alarm, thermocouple failure indication and other alarm protection functions
Control modeZero crossing trigger mode of solid state relay
Overtemperature treatmentWhen over temperature occurs in a certain temperature zone, the temperature over temperature alarm system of the corresponding temperature zone will immediately send out sound and light alarm signal and cut off the heating of the temperature zone at the same time, and the buzzer will send out continuous alarm sound
computer control systemDCS (distributed control system) control system is adopted
Lower single loop intelligent instrument control, upper computer monitoring
Friendly man-machine interface, multiple program storage, convenient for users to edit and call
Real time display of temperature and alarm status.Data can be stored and printed out.
The computer control system has the function of slope heating, which can effectively extend the service life of muffle tube
Provide furnace temperature calibration function, better fit process requirements
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA