hph-cond-do
1 Year
1 Year
OEM, ODM, Obm
Plastic
Electric
5.000Ω * Cm~100.0mΩ * Cm
0-100ppt
Single Item
60.0X43.0X13.0 Cm
3.000 Kg
Resound
Box
60.0X43.0X13.0 Cm
China
Product Description
Overview



Product Features
• Three-channel instrument, pH/COND/DO three parameters can be displayed simultaneously on the split screen (DPCD100T)
• High-resolution 7-inch super-large touch colour screen, beautiful, clear, and easy to operate
• Intelligent operating system with electrode management, data management, and parameter setting functions
• 5-point calibration (pH), supports automatic temperature compensation, and electrode diagnostic function
• Data storage: 500 sets / parameter (number, value, unit, temperature, time) (e.g. DPCD100T: can store 1500 sets)
• Continuous measurement mode and interval timed measurement mode can be set
• Data lock function; supports Chinese and English operation interface
• Data printing: wireless Bluetooth connection to printer, direct printing of measurement data (printer is optional)
• Data output: U disk/PC/printer
• Dust and water protection level: IP54
• Comes with magnetic stirrer, electrode holder, and standard solutions
• High-resolution 7-inch super-large touch colour screen, beautiful, clear, and easy to operate
• Intelligent operating system with electrode management, data management, and parameter setting functions
• 5-point calibration (pH), supports automatic temperature compensation, and electrode diagnostic function
• Data storage: 500 sets / parameter (number, value, unit, temperature, time) (e.g. DPCD100T: can store 1500 sets)
• Continuous measurement mode and interval timed measurement mode can be set
• Data lock function; supports Chinese and English operation interface
• Data printing: wireless Bluetooth connection to printer, direct printing of measurement data (printer is optional)
• Data output: U disk/PC/printer
• Dust and water protection level: IP54
• Comes with magnetic stirrer, electrode holder, and standard solutions
Models | DPH100T | DEC100T | DDO100T | ||
Parameter | pH/mV,°C | ✓ | - | - | |
mV(ORP),°C | ✓ | - | - | ||
Cond/TDS/Sal./Res.,°C | - | ✓ | - | ||
Dissolved Oxygen DO | - | - | ✓ | ||
PH | Measurement Range | (-2.000~20.000) pH | ✓ | - | - |
Resolution | 0.01/0.001 | ✓ | - | - | |
Accuracy | ±0.002pH±1 digit | ✓ | - | - | |
Calibration Points | 1-5 Auto | ✓ | - | - | |
Automatic Temp. Compensation | (0.0-100.0) °C/(32.0-212.0)°F | ✓ | - | - | |
ORP | Measurement Range | (-1999.9 - +1999.9) mV | ✓ | - | - |
Resolution | 0.1/1 | ✓ | - | - | |
Accuracy | ±0.03%F.S±1 digit | ✓ | - | - | |
Conductivity | Measurement Range | 0-19.999μS/cm; 20.0-199.9μS/cm; 200-1999μS/cm; 2.00-19.99mS/cm; 20.00-199.9mS/cm; 200.0-2000mS/cm (K=10),TDS 0 - 100.0g/L (Auto-ranging) ;Resistivity 5.000Ω * cm~100.0MΩ * cm;Salinity 0-100ppt | - | ✓ | - |
Calibration Points | 1 point | ✓ | - | ||
Resolution | 0.001/0.01/0.1/1 | - | ✓ | - | |
Automatic Temp. Compensation Range | - | ✓ | - | ||
Accuracy | ±0.5% F.S±1 digit | - | ✓ | - | |
Dissolved Oxygen | Measurement Range | (0.00-20.00) mg/L | - | - | ✓ |
Accuracy | ±0.30 mg/L | - | - | ✓ | |
DO Saturation Range | (0.0-200.0)% | - | - | ✓ | |
Barometric Compensation | (0-200.0) kPa | - | - | ✓ | |
Automatic Temp. Compensation Range | (0.0-50.0) °C/(32.0-122.0)°F | - | - | ✓ | |
Salinity Compensation | 0-45ppt | - | - | ✓ | |
Temperature | Measurement Range | (0.0-100.0) °C/(32.0-212.0)°F | ✓ | ✓ | ✓ |
Measurement Accuracy | ±0.2°C | ✓ | ✓ | ✓ | |
General | Data Output | U disk/PC/Printer | ✓ | ✓ | ✓ |
Power Supply | DC12V | ✓ | ✓ | ✓ | |
Accessory | Instrument | ✓ | ✓ | ✓ | |
Stainless Steel Temp. Electrode DTEMP-01 | ✓ | - | - | ||
Glass Charging Conductivity Electrode DCON201TG | - | ✓ | - | ||
Plastic Dissolved Oxygen Electrode DDO01-2M (Polarographic) | - | - | ✓ | ||
pH Buffer Solution: 50mL pH4.00/6.86/9.18 1 Bottle Each | ✓ | - | - | ||
Conductivity Standard Solution: 50mL 146.6μS/1408μS/12.85mS/cm 1 Bottle Each | - | ✓ | - | ||
DDOS-01 Dissolved Oxygen Internal Standard: 30mL, 1 Bottle | - | - | ✓ | ||
DDOSC Dissolved Oxygen Calibration Membrane: 3 pcs/set, 1 set | - | - | ✓ | ||
PC Data Cable | ✓ | ✓ | ✓ | ||
Omnidirectional Electrode Holder DF01 | ✓ | ✓ | ✓ | ||
Magnetic Stirrer | ✓ | ✓ | ✓ | ||
Power Adapter | ✓ | ✓ | ✓ | ||
Instruction Manual | ✓ | ✓ | ✓ |
Models | DPC100T | DPD100T | DCD100T | DPCD100T | ||
Parameter | pH/mV,°C | ✓ | ✓ | - | ✓ | |
mV(ORP),°C | ✓ | ✓ | - | ✓ | ||
Cond/TDS/Sal./Res.,°C | ✓ | - | ✓ | ✓ | ||
Dissolved Oxygen DO | - | ✓ | ✓ | ✓ | ||
PH | Measurement Range | (-2.000~20.000) pH | ✓ | ✓ | - | ✓ |
Resolution | 0.01/0.001 | ✓ | ✓ | - | ✓ | |
Accuracy | ±0.002pH±1 digit | ✓ | ✓ | - | ✓ | |
Calibration Points | 1-5 Auto | ✓ | ✓ | - | ✓ | |
Automatic Temp. Compensation | (0.0-100.0) °C/(32.0-212.0)°F | ✓ | ✓ | - | ✓ | |
ORP | Measurement Range | (-1999.9 - +1999.9) mV | ✓ | ✓ | - | - |
Resolution | 0.1/1 | ✓ | ✓ | - | - | |
Accuracy | ±0.03%F.S±1 digit | ✓ | ✓ | - | - | |
Conductivity | Measurement Range | 0-19.999μS/cm; 20.0-199.9μS/cm; 200-1999μS/cm; 2.00-19.99mS/cm; 20.00-199.9mS/cm; 200.0-2000mS/cm (K=10),TDS 0 - 100.0g/L (Auto-ranging) ;Resistivity 5.000Ω * cm~100.0MΩ * cm;Salinity 0-100ppt | ✓ | - | ✓ | ✓ |
Calibration Points | 1 point | ✓ | - | ✓ | ✓ | |
Resolution | 0.001/0.01/0.1/1 | ✓ | - | ✓ | ✓ | |
Automatic Temp. Compensation Range | ✓ | - | ✓ | ✓ | ||
Accuracy | ±0.5% F.S±1 digit | ✓ | - | ✓ | ✓ | |
Dissolved Oxygen | Measurement Range | (0.00-20.00) mg/L | - | ✓ | ✓ | ✓ |
Accuracy | ±0.30 mg/L | - | ✓ | ✓ | ✓ | |
DO Saturation Range | (0.0-200.0)% | - | ✓ | ✓ | ✓ | |
Barometric Compensation | (0-200.0) kPa | - | ✓ | ✓ | ✓ | |
Automatic Temp. Compensation Range | (0.0-50.0) °C/(32.0-122.0)°F | - | ✓ | ✓ | ✓ | |
Salinity Compensation | 0-45ppt | - | ✓ | ✓ | ✓ | |
Temperature | Measurement Range | (0.0-100.0) °C/(32.0-212.0)°F | ✓ | ✓ | ✓ | ✓ |
Measurement Accuracy | ±0.2°C | ✓ | ✓ | ✓ | ✓ | |
General | Data Output | U disk/PC/Printer | ✓ | ✓ | ✓ | ✓ |
Power Supply | DC12V | ✓ | ✓ | ✓ | ✓ | |
Accessory | Instrument | ✓ | ✓ | ✓ | ✓ | |
Glass pH Electrode D201G | ✓ | ✓ | - | ✓ | ||
Stainless Steel Temp. Electrode DTEMP-01 | ✓ | ✓ | ✓ | ✓ | ||
Glass Charging Conductivity Electrode DCON201TG | ✓ | - | - | ✓ | ||
Plastic Dissolved Oxygen Electrode DDO01-2M (Polarographic) | - | ✓ | ✓ | ✓ | ||
pH Buffer Solution: 50mL pH4.00/6.86/9.18 1 Bottle Each | ✓ | ✓ | ✓ | ✓ | ||
Conductivity Standard Solution: 50mL 146.6μS/1408μS/12.85mS/cm 1 Bottle Each | ✓ | ✓ | ✓ | ✓ | ||
DDOS-01 Dissolved Oxygen Internal Standard: 30mL, 1 Bottle | - | ✓ | ✓ | ✓ | ||
DDOSC Dissolved Oxygen Calibration Membrane: 3 pcs/set, 1 set | - | ✓ | ✓ | ✓ | ||
PC Data Cable | ✓ | ✓ | ✓ | ✓ | ||
Omnidirectional Electrode Holder DF01 | ✓ | ✓ | ✓ | ✓ | ||
Magnetic Stirrer | ✓ | ✓ | ✓ | ✓ | ||
Power Adapter | ✓ | ✓ | ✓ | ✓ | ||
Instruction Manual | ✓ | ✓ | ✓ | ✓ |
Resound Photoelectric Technology Research Institute (LSRPTR)
Resound Photoelectric Technology Research Institute (LSRPTR), also known as Resound Research Institute, is affiliated with China Haiheng International Trade Group Co., Ltd. (CHHGC). As an investment attraction enterprise in Zhongyuan Science and Technology City and a construction unit of the Zhongyuan Aurora Laboratory, the institute is committed to the industrialization of scientific and technological achievements, guided by market demand.
Resound Photoelectric Technology Research Institute (LSRPTR), also known as Resound Research Institute, is affiliated with China Haiheng International Trade Group Co., Ltd. (CHHGC). As an investment attraction enterprise in Zhongyuan Science and Technology City and a construction unit of the Zhongyuan Aurora Laboratory, the institute is committed to the industrialization of scientific and technological achievements, guided by market demand.
Technical Cooperation
Resound Research Institute has established technical cooperation with numerous well-known domestic and foreign universities, research institutes, and enterprise platforms, including:Tsinghua University
Lanzhou University
Zhengzhou University
Altai State Technical University of Russia
Northwestern Polytechnical University
Chinese Academy of Engineering
Henan Academy of Sciences
China Electronics Technology Group
CGN Group
Xiamen University
Henan University
National University
University of Electronic Science and Technology of China
Chinese Academy of Sciences
China Academy of Engineering Physics
China Shipbuilding Group
China Electronics Group
Henan Inspection Group
Lanzhou University
Zhengzhou University
Altai State Technical University of Russia
Northwestern Polytechnical University
Chinese Academy of Engineering
Henan Academy of Sciences
China Electronics Technology Group
CGN Group
Xiamen University
Henan University
National University
University of Electronic Science and Technology of China
Chinese Academy of Sciences
China Academy of Engineering Physics
China Shipbuilding Group
China Electronics Group
Henan Inspection Group
Research and Development Fields
* Applications of Micro-Electromechanical and Lithography Technology* Optoelectronics and Spectroscopy Technology
* High-Power Laser and Device Preparation Technology
* Nuclear Instrument and Emergency Equipment System Applications