CJX4
AC
3
3
220-240V, 400-440V
18A, 24A, 29A, 36A, 48A, 58A, 72A, 87A
Ac Contactors
Electromagnetic Relay
Miniature
-25 to +60 centigrade
-40 to +70 centigrade
3000m
3
3
TIANSHUI 213
Carton
IEC60947-4-1
China
8536490090
Product Description
CJX4-kd series of capacitor changeover contactor is used in the circuit of AC 50Hz(or 60Hz), rated insulation voltage up to 690V, rated current is from 18A up to 87A for AC-6b at rated voltage of 400V to 440V for the purpose of closing or breaking capacitor bank, which is used for low voltage reactive power compensation, and then adjusting power factor value of power system. Contactor with inrush current suppression device can effectively reduce the impact on capacitor bank from switching inrush current and reduce operation over-voltage.
Model | CJX4~25kd | CJX4~32kd | CJX4~40kd | CJX4~50kd | CJX4~60kd | CJX4~80kd | CJX4~100kd | CJX4~125kd | ||
Electrical parameters | ||||||||||
Rated insulation voltage Ui (V) | 690 | |||||||||
Rated voltage Ue (V) | 220-240V/400-440V | |||||||||
Conventional thermal current Ith (A) (AC-6b) | 25 | 32 | 40 | 50 | 60 | 80 | 100 | 125 | ||
Rated current Ie (A) | AC-6b | 220-240V | 18 | 24 | 29 | 36 | 48 | 58 | 72 | 87 |
400-440V | 18 | 24 | 29 | 36 | 48 | 58 | 72 | 87 | ||
controlled power (Kvar) | AC-6b | 220-240V | 6.7 | 8.5 | 10 | 15 | 20 | 25 | 25 | 40 |
400-440V | 12.5 | 16.7 | 20 | 25 | 33.3 | 40 | 50 | 60 | ||
Inrush current suppression capacity (times) | 15 | |||||||||
Contact quantity | 3P+2NO/3P+2NC/3P+1NC+1NC | 3P+2NO+1NC/3P+1NO+2NC | ||||||||
Auxiliary contact | ||||||||||
Rated Voltage Ue (V) | AC 380V, DC 220V | |||||||||
Conventional thermal current Ith (A) | 10 | |||||||||
Rated current Ie (A) | AC-15 (360VA) | 0.95 | ||||||||
DC-13 (33W) | 0.15 | |||||||||
Mini. load | 24V 10mA | |||||||||
Coil | ||||||||||
Standard coil voltage Us (V) | 24V, 36V, 48V, 110V , 220V, 380V (50Hz/60Hz) | |||||||||
Pull-in voltage (V) | 0.85US-1.10Us (-25 to +60 centigrade) | |||||||||
Drop-out voltage (V) | 0.20Us-0.75Us (-25 to +60 centigrade) | |||||||||
Pull-in power (VA) | 76 | 110 | 230 | |||||||
Hold power (VA) | 10 | 11 | 32 | |||||||
AC-6b | Electrical life (10000 times) | 12 | 12 | 10 | 10 | 10 | 10 | 10 | 10 | |
Operation frequency per hour | 300 | 300 | 300 | 300 | 120 | 120 | 120 | 120 | ||
Mechanical life (10000 times) | 300 | |||||||||
Standard | IEC60947-4-1, EN60947-4-1 | |||||||||
Certificate | CE | |||||||||
Operation ambient temperature | -25 to +60 centigrade | |||||||||
Storage temperature | -40 to +70 centigrade | |||||||||
Altitude (m) | 3000m, if higher than 3000m, then derate | |||||||||
Class of pollution | 3 | |||||||||
Installation category | 3 | |||||||||
Net weight (KG) | 0.44 | 0.63 | 1.31 | 1.52 |
CJX4-3220kd, CJX4-3202kd, CJX4-3211kd,
CJX4-4020kd, CJX4-4002kd, CJX4-4011kd,
CJX4-5021kd, CJX4-5012kd,
CJX4-6021kd, CJX4-6012kd,
CJX4-8021kd, CJX4-8012kd,
CJX4-10021kd, CJX4-10012kd,