Cdada Dam11 MCCB Moulded Case Circuit Breaker Adjustable Electronic Fixed Type Electrical

Price $430.00 Compare
Min Order 1000 Pieces
Shipping From Shanghai, China
Popularity 237 people viewed
Quantity
+-
 

Shanghai DaDa Electric Co., Ltd.

VIP   Audited Supplier 5 years
Profile Certified by SGS/BV
DAM11
Low Voltage Circuit Breakers
Manual Type
Normal Type Circuit Breaker
Arc Chamber
Fixed
MCCB
3
Circuit Breaker
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection
ISO9001-2000, CE, CB, CCC, Kema, Asta, Semko, RoHS
BMC Unflaming Material
BMC Unflaming Material
with Terminal Box
Left Side
1000V
400/415V
CDADA, OEM, ODM
Carton
16A-1250A
Shanghai, China
8536200000
Product Description
DAM11 Series Moulded-case Circuit Breaker
Product overview

DAM11, DAM11LY, DAM11RT, DAM11E and DAM11EL series of circuit breakers are new upgraded circuit breakers researched and developed by the company combined with the advantages of similar international products and demand of domestic and international markets.
With insulation voltage up to 1000V, the circuit breaker is applicable for distribution systems of AC50Hz, rated working voltage 690V and rated working current from 10A to 800A, used to distribute electric power energy, protect circuits and power equipment against overload, short circuit, under voltage and so on, also can be used for infrequent startup of motor and protect it from overload, short circuit or under voltage.
It is featured with small size, high breaking, short flashover, etc., is the ideal product for users. It can be vertically installed or horizontally installed.
DAM11DC series DC moulded-case circuit breaker (hereinafter referred to as circuit breaker) is suitable for DC systems of rated voltage up to and including DC 1000V and rated current 10~800A, used to distribute electric power energy, protect circuits and power equipment against overload, short circuit and so on.
The products can be fed with wires from top and bottom, and it is polarity-free.
It complies with the standards IEC60947-2, GB14048.2, etc.
Ambient and installation conditions

 Altitude up to 2000m;
 Ambient medium temperature should be within -5ºC to +40ºC (+45ºC for marine products);
 It can withstand the effect of damp air;
 It can withstand the effect of moulds;
 It can withstand the effect of nuclear radiation;
 The max inclination is 22.5ºC.
 It still can work reliably when the ship subjects to normal vibration;
 t can still work reliably if the product subjects to the earthquake (4g).
 Places where the surrounding medium is free from explosion danger, and far away  from gas or conductive dust that would erode the metal or destroy the insulation;
Keep away from rain or snow.  
DAM11 thermal overload technical data sheet
Frame current (A)125160250400630800
ModelDAM11-125CDAM11-125SDAM11-125HDAM11-160CDAM11-160SDAM11-160HDAM11-250CDAM11-250SDAM11-250HDAM11-400SDAM11-400HDAM11-630SDAM11-630HDAM11-800SDAM11-800H
Pole number1, 2, 3, 42, 3, 43, 43, 43, 43, 4
Rated current (A)10, 16, 20, 32, 25, 40, 50,63, 80, 100, 12563, 80, 100, 125, 140, 160
100, 125, 140, 160, 180,200, 225, 250
250,315,350,400250, 315, 350, 400, 500, 630500, 630, 700, 800,1000,1250
Rated voltage (V)AC400VAC400VAC400VAC400VAC400VAC400V
Rated insulation voltage (V)AC1000VAC1000VAC1000VAC1000VAC1000VAC1000V
Short-circuit breaking capacity(KA)Icu/IcsAC400V10/1518/1525/1820/1525/1835/2525/1525/1835/2535/2550/3535/2550/3550/3565/65
Operating cycle numberElectrical life600030003000200020001500
Mechanical life900070007000400040004000
Outline dim(mm)1P25-130-68-90---    
a-b-c-ca2P50-130-68-9060-155-68-9060-155-88-115    
 3P75-130-68-9090-155-68-9090-155-88-115105-165-68-92105-165-88-115140-257-103-155140-257-103-155210-275-103-155
4P100-130-68-90120-155-68-90120-155-88-115140-165-68-92140-165-88-115184-257-103-155184-257-103-155280-275-103-155
Weight (kg)1P0.32---     
2P0.50.5511.11.51.75.55.79.5
3P0.550.651.11.21.92.177.512.5
4P0.650.81.41.5    
Electric operating device (MD)   
External driving operating handle   
Automatic releaseThermal electromagnetic typeThermal electromagnetic typeThermal electromagnetic type
DAM11RT thermal adjustable and magnetic adjustable (TAMA) technical data sheet
Frame current (A)1602504006301250
ModelDAM11RT-160SDAM11RT-160HDAM11RT-250SDAM11RT-250HDAM11RT-400SDAM11RT-400HDAM11RT-630SDAM11RT-630HDAM11RT-1250SDAM11RT-1250H
Pole number3, 43, 43, 43, 43, 4
Rated current (A)20-25, 25-32, 32-40, 40-50, 50-63,100-125, 125-160, 160-200, 200-250A200-250, 250-320,320-400400-500, 500-630630-800,800-1250
63-80,80-100, 100-125A, 125-160AAC400VAC400VAC400V
Rated voltage (V)AC400VAC400VAC1000VAC1000VAC1000V
Rated insulation voltage (V)AC1000VAC1000V35/2550/3535/2550/3550/3565/50
Short-circuit breaking capacity(KA)Icu/IcsAC400V25/1835/2525/1835/25200020001500
Operating cycle numberElectrical life30003000400040004000
Mechanical life70007000100010001000
Outline dim(mm) a-b-c-ca    
3P90-155-68-9090-155-88-115105-165-68-92105-165-88-115140-257-103-155140-257-103-155210-275-103-155
4P120-155-68-90120-155-88-115140-165-68-92140-165-88-115185-257-103-155185-257-103-155280-275-103-155
    
Weight (kg)3P11.11.51.75.55.79.5
4P1.11.71.92.177.512.5
Electric operating device (MD)  
External driving  
operating handle
Automatic releaseThermal electromagnetic typeThermal electromagnetic type