China ABC Cable Insulation Piercing Connector

Price $5.00 Compare
Min Order 100 Pieces
Shipping From Jiangsu, China
Popularity 482 people viewed
Quantity
+-
 

Jiangsu Chuandu Electrical Technology Co., Ltd.

VIP   Audited Supplier 7 years
Profile Certified by SGS/BV
Injection Molding
En 50483
Substation Fittings, Line Fittings
Distribution Fitting
Accept
Free
Smooth
12 Months
Al & Cu
Da Sheng
Wooden Case
Insulated
Yangzhou City, China
8536909000
Product Description
Insulated Cable Piercing Connector Clamp 
General:
This series insulation piercing connector is mainly used for wire branching The applicable voltage is 10kV, 1kV and less more than 1kV.It has the following function and features: 
a. Simple installation. The insulated layer of lead needn't be stripped. Put the mainline and branch line into connector correctly and screw  the moment nut off with a box spanner.

b. Small contact resistance and low temperature rising . The specially-made moment bolt guarantees constant piercing pressure, which enable the connector to get a good electric contact without any excessive conductor damage, and guarantee the normal performance life of circuitry. 

c.  Sealed stunture and high surability. The internal adopts whole sealing structure and is filled with insulating heat conducting grease, which improves insulating strength and security.  
d.  Wide application range . It is applicable to branch connection of copper and  aluminum conductor, hetero-dia metric conductor,  and butt joint  of isodiametric conductor. It is also applicable to transition branch connection  of copper and aluminum insulated lead.  


Remarks
1. The conductor used for insulation piercing connector must conform with international standard.

2. The installation operator must be familiar with installation technique.

3. Please put on insulating gloves and use insulating box spanner during hot-line work.

4. The insulation piercing connector is a kind of one-time product. Please do not use it again after dismantling because of dental pattern transfiguration.


Application
a.Installing and fixing main cable in traditional way.

b. Stripping outer insulator of main cable for 0.6m  at part that need part(don,t destroy insulaton  layer for phase).

c.Choosing branch cable ( not more than 3m)  whose distance is the same as electric meter box, and strip insulator at two terminals.

d.Installing the separator vertically by turns (the sepatator distance is more than 10cm).

>>------------------------------------------------------------------




>>------------------------------------------------------------------