The VKVP mobile oil purifier can remove water, pollutants, particles, and gases from hydraulic and lubricating oils of various viscosities. The power parameters given on the nameplate include the rated voltage of the pump motor. Partial control voltage is 24V DC.
The VKVP series oil purifier can remove the following substances:
Water: 100% free water and 90% dissolved water.
Gas: 100% free gas and 90% dissolved gas, related to the set value of operating vacuum degree.
Dirt: sediment, pollution particles.
Type VKVP-100
Operating conditionWorking medium Oil
Operating temperature 20 - 80ºC
Capacity 6000Liter/hr
Max viscosity 100cSt
Cleanness class ≤NAS Class 6
Impurity content ≤1μm
Moisture content at outlet of oil ≤50ppm
Analyzer Online moisture analyzer
Fluid system
Inlet pressure -0.4 - 3bar
Inlet pressure sensor set point (PS01):-0.7 bar
Outlet pump flow(P02); 100 L/min(50 Hz)
Pressure sensor setting range (PS02): -0.45 to -0.9bar
Outlet pressure sensor set point (PS04): 5.5 bar
Outlet pressure 8bar Max
Temperature sensor range 0 to 100ºC
Vacuum system
Run vacuum -0.6~-0.95 bar
Vacuum pump type rotary-vane pump
Exhaust back pressure 0.2 bar Max
Structural materials
Frame Carbon Steel
Vacuum tank Carbon Steel/ Stainless steel
Pipe joint & Fastener Carbon Steel/ Stainless steel
Electric control box Carbon Steel
Pump Carbon Steel & Cast iron (shell)
- Interface
Outlet DN50
Vacuum pump Vent Internal thread G1 1/4"
- Electrical System
Total power 38KW
Control voltage 220 V AC & 24 V DC
Motor power (Outlet pump M02) 3.0KW (50 Hz)
Motor power (Vacuum pump M03) 2.2kW (50 Hz)
Heating power (HE01) 30KW
Caution : Details power parameters according to Product Instruments
- Instrumentation
INTERFACE
EMERGENCY STOP
ALARM LIGHT
Inlet lens (SF01)
Inlet pressure sensor (PS01)
Vacuum Pressure sensor(PS02)
Outlet Pressure sensor(PS03)
Outlet Pressure sensor(PS04)
Thermal resistance (TA01)
Level Switch (LS01,02,03)
Inlet Pressure gauge (PG01)
Filter Pressure gauge (PG04)
Filter Pressure gauge (PG05)
We will ship in 24 hours. |