Water Boiler, Steam Boilers, Hot Water Boiler, Oil Boiler, Hot Air Boiler
Oil-Fired
Bulk Boiler
Fire Tube
Hot Water
Natural Circulation
Horizontal Boiler
Pressure
Chamber Combustion Boiler
Industrial, Power Station
1
30 Days
No
≥96.2
Weifu
Wooden Packaging
Customized
Jiangsu
Product Description
Horizontal oil-fired gas pressure hot water boiler

Boiler structure: Chengfu horizontal oil-fired and gas-fired hot water boilers are divided into two-pass and three-pass full wet back structures with central flame return. The three-pass fire tube boiler consists of a corrugated furnace, a light tube or a threaded tube arranged symmetrically in the center to form a heating surface. The high-temperature flue gas turns from the small smoke chamber into the smoke pipe to the front smoke box and then enters the rear smoke box and is discharged into the atmosphere through the chimney. The unique structure and novel design, sufficient heating surface and some enhanced heat transfer methods make the boiler thermal efficiency reach an ideal state. In terms of safety, it integrates explosion-proof doors and digital control systems to ensure safety.
Boiler advantages: The horizontal series of hot water boilers are divided into two structures: normal pressure and pressure-bearing. The wide range of products depends on the user's site. The pressure-bearing hot water boiler is more adaptable to users with higher heating requirements. The boiler is shipped as a whole (integrating safety room, inlet and outlet valves, check valves, sewage room, instruments, and control systems), and the pipeline systems within the scope of supply are already connected. The boiler is made of color steel plate, the base, front and rear smoke boxes are beautifully designed, and the installation is simple and quick. It can be put into operation by simply connecting the power supply, water source, fuel pipeline, water inlet and outlet pipeline, sewage pipeline, etc.

Gas pressure hot water boiler (30 mg) parameter table | ||||||||||||
Modal | Unit | WNS0.7-0.7/95/70-Q.Y | WNS1.05-1.0/115/70-Q.Y | WNS1.4-1.0/115/70-Q.Y | WNS2.1-1.0/115/70-Q.Y | WNS2.8-1.25/115/70-Q.Y | WNS4.2-1.25/115/70-Q.Y | WNS5.6-1.25/115/70-Q.Y | WNS7.0-1.25/115/70-Q.Y | WNS10.5-1.25/115/70-Q.Y | WNS14-1.25/115/70-Q.Y | |
Rated output | MV | 0.7 | 1.05 | 1.4 | 2.1 | 2.8 | 4.2 | 5.6 | 7.0 | 10.5 | 14.0 | |
Rated working pressure | Mpa | 0.7 | 1.0 | 1.0 | 1.0 | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 | |
Outlet/return water temperature | ºC | 95/70 | 115/70 | 115/70 | 115/70 | 115/70 | 115/70 | 115/70 | 115/70 | 115/70 | 115/70 | |
Boiler design thermal efficiency | % | ≥96.2 | ||||||||||
Heating area | M² | 23.13 | 30.99 | 40.81 | 64.7 | 79.4 | 128.6 | 176.3 | 234.2 | 360.2 | 409.5 | |
Steel furnace water capacity | M³ | 2.43 | 4.1 | 4.5 | 5.28 | 6.05 | 7.97 | 10.382 | 15.47 | 21.5 | 28.5 | |
Flue size | mm | 320*200 | 490*260 | 462*262 | 580*320 | 650*320 | 800*400 | 800*400 | 850*500 | 1100*500 | 1300*500 | |
Water return diameter | DN | 80 | 100 | 100 | 125 | 150 | 200 | 200 | 200 | 200 | 250 | |
Water outlet diameter | DN | 80 | 100 | 100 | 125 | 150 | 200 | 200 | 200 | 200 | 250 | |
Safety valve diameter | DN | 40 | 40 | 50 | 50 | DN50*2 | DN50*2 | ND65*2 | DN80*2 | DN100*2 | DN125*2 | |
Sewage diameter | DN | 40 | 40 | 40 | 40 | 40 | 50 | 50 | 50 | DN50*3 | DN50*3 | |
Fuel consumption | 0# Light diesel | kg/h | 60.1 | 93.2 | 129.8 | 186 | 246 | 377 | 535 | 607 | 899.6 | 1180 |
Natural gas | Nm³/h | 67.2 | 103.9 | 156.2 | 208.1 | 280.9 | 418.1 | 542 | 682 | 1022 | 1460 | |
Shipping Weight | KG | 3650 | 4600 | 5500 | 8600 | 9500 | 12800 | 16 | 23.5 | 37.5 | 46.5 | |
Dimensions | Length | mm | 3250 | 3500 | 3800 | 4560 | 4700 | 5700 | 5900 | 6900 | 7300 | 8000 |
Width | mm | 1890 | 1960 | 2000 | 2200 | 2500 | 2650 | 2750 | 3150 | 3450 | 3750 | |
Height | mm | 2230 | 2500 | 2600 | 2650 | 2800 | 2900 | 2850 | 3260 | 3550 | 3850 |
Gas pressure hot water boiler (120 mg) parameter table | ||||||||||||
Modal | Unit | WNS0.7-0.7/95/70-Q.Y | WNS1.05-1.0/115/70-Q.Y | WNS1.4-1.0/115/70-Q.Y | WNS2.1-1.0/115/70-Q.Y | WNS2.8-1.25/115/70-Q.Y | WNS4.2-1.25/115/70-Q.Y | WNS5.6-1.25/115/70-Q.Y | WNS7.0-1.25/115/70-Q.Y | WNS10.5-1.25/115/70-Q.Y | WNS14-1.25/115/70-Q.Y | |
Rated output | MV | 0.7 | 1.05 | 1.4 | 2.1 | 2.8 | 4.2 | 5.6 | 7.0 | 10.5 | 14 | |
Rated working pressure | Mpa | 0.7 | 1.0 | 1.0 | 1.0 | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 | 1.25 | |
Outlet/return water temperature | ºC | 95/70 | 115/70 | 115/70 | 115/70 | 115/70 | 115/70 | 115/70 | 115/70 | 115/70 | 115/70 | |
Boiler design thermal efficiency | % | ≥96.2 | ||||||||||
Heating area | M² | 23.13 | 30.99 | 40.81 | 64.7 | 79.4 | 128.6 | 176.3 | 234.2 | 360.2 | 409.5 | |
Steel furnace water capacity | M³ | 2.23 | 3.9 | 3.5 | 5.28 | 6.05 | 7.97 | 10.382 | 15.47 | 21.5 | 28.5 | |
Flue size | mm | 320*200 | 490*260 | 462*262 | 580*320 | 650*320 | 800*400 | 800*400 | 850*500 | 1100*500 | 1300*500 | |
Water return diameter | DN | 80 | 100 | 100 | 125 | 150 | 200 | 200 | 200 | 200 | 250 | |
Water outlet diameter | DN | 80 | 100 | 100 | 125 | 150 | 200 | 200 | 200 | 200 | 250 | |
Safety valve diameter | DN | 40 | 40 | 50 | 50 | DN50*2 | DN50*2 | DN65*2 | DN80*2 | DN100*2 | DN125*2 | |
Sewage diameter | DN | 40 | 40 | 40 | 40 | 40 | 50 | 50 | 50 | DN50*3 | DN50*3 | |
Fuel consumption | 0# Light diesel | kg/h | 64.5 | 96.9 | 129.8 | 192.6 | 260 | 384.1 | 511.2 | 638.1 | 959 | 1256 |
Natural gas | Nm³/h | 77.4 | 116.8 | 156.2 | 230.2 | 313.9 | 463.1 | 615.9 | 765.5 | 1157 | 1541 | |
Shipping Weight | KG | 3250 | 4200 | 4800 | 8100 | 9000 | 12000 | 15200 | 22000 | 36600 | 45700 | |
Dimensions | Length | mm | 3150 | 3400 | 3600 | 4460 | 4600 | 5600 | 5600 | 6800 | 7200 | 7900 |
Width | mm | 1560 | 1660 | 1600 | 1900 | 2100 | 2250 | 2250 | 2800 | 3250 | 3650 | |
Height | mm | 1900 | 2200 | 2200 | 2300 | 2400 | 2700 | 2650 | 3100 | 3350 | 3750 |






1. How to buy a good boiler?
A: Choose a good supplier.
B: Specification is clear, steam or hot water, capacity,fuel,pressure and so on
C:Price is not the only problem, quality and service also important.
2. What is your main product?
A:Steam boiler, hot water boiler and thermal oil boiler.Gas fired boiler, oil fired boiler, diesel fired boiler, coal fired boiler, biomass fired boiler,Industry boiler and so on.
3. Q: How long is your lead time?
A: Generally it is 30 days, depends on your needs and project scales.