LXSGY-15S-50S
Horizontal
Cold Water
Class B / Class C / R160
Digital
15-50mm
Civil
Speed of Water Meter
General Water Meter
Dry Water Meter
Traditional
OEM
Export Carton
Nylon body, nylon connectors
Ningbo, China
9028201000
Product Description
Multi Jet Dry type
Material body: Nylon plastic
Sizes: DN15 to 50mm (½" - 2"), Available for cold water (40°C), hot water(90°C)
Accuracy: DN15(½"), Class B / Class C / R160
DN20-50mm, (¾" - 2") Class B
For Liter Choice: 1 liter/pulse, 10 liters/pulse, 100 liters/pulse
For Gallon Choice: 0.1 gallon/pulse, 1 gallon/pulse, 10 gallon/pulse
MAIN TECHNICAL DATA According to ISO4064 (GB/T778.1-1996) Standard
Size | Class | Qs Overload flow | Qp Nominal flow | Qt Transitional flow | Qmin Min flow | Min reading | Max reading | |
DN(mm) | Inch | m³/h | L/h | m³ | ||||
15 | 1/2" | A | 3 | 1.5 | 150 | 60 | 0.0001 | 99999 |
B | 120 | 30 | ||||||
C | 22.5 | 15 | ||||||
20 | 3/4" | A | 5 | 2.5 | 250 | 100 | 0.0001 | 99999 |
B | 200 | 50 | ||||||
C | 37.5 | 25 | ||||||
25 | 1" | A | 7 | 3.5 | 350 | 140 | 0.0001 | 99999 |
B | 280 | 70 | ||||||
32 | 11/4" | A | 12 | 6 | 600 | 240 | 0.0001 | 99999 |
B | 480 | 120 | ||||||
40 | 11/2" | A | 20 | 10 | 1000 | 400 | 0.001 | 99999 |
B | 800 | 200 | ||||||
50 | 2" | A | 30 | 15 | 1500 | 600 | 0.001 | 99999 |
B | 1200 | 300 |
MAIN TECHNICAL DATA According to ISO4064 (GB/T778.1-2007) Standard
DN SIZE | Mm Inch | 15 1/2" | 20 3/4" | 25 1" | 32 11/4" | 40 11/2" | 50 2" |
Q4(m³/h) | 3.125 | 5 | 7.875 | 12.5 | 20 | 31.25 | |
Q3(m³/h) | 2.5 | 4 | 6.3 | 10 | 16 | 25 | |
R80 | Q2(L/h) | 50 | 80 | 126 | 200 | 320 | 500 |
Q1(L/h) | 31.25 | 50 | 78.75 | 125 | 200 | 312.5 | |
R100 | Q2(L/h) | 40 | 64 | 100.8 | 160 | 256 | 400 |
Q1(L/h) | 25 | 40 | 63 | 100 | 160 | 250 | |
R125 | Q2(L/h) | 32 | 51.2 | 80.64 | 128 | 204.8 | 320 |
Q1(L/h) | 20 | 32 | 50.4 | 80 | 128 | 200 | |
R160 | Q2(L/h) | 25 | 40 | 63 | 100 | 160 | 250 |
Q1(L/h) | 15.62 | 25 | 39.37 | 62.5 | 100 | 156.2 | |
Min reading(m³) | 0.00005 | 0.00005 | 0.00005 | 0.00005 | 0.001 | 0.001 | |
Max reading(m³) | 99,999 | 99,999 | 99,999 | 99,999 | 99,999 | 99,999 | |
Max pressure(MAP) | 16 | 16 | 16 | 16 | 16 | 16 | |
Max loss(ΔP) | 63 | 63 | 63 | 63 | 63 | 63 | |
Max temperature | T50 | T50 | T50 | T50 | T50 | T50 | |
Pulse output option | Vmax=24V, Imax=100mA, Pmax=2W |
INDICATING ERROR
At low zone is ±5% from minimum flow rate (qmin) to transitional flow rate (qt) exclusive boundary
At high zone is ±2% from transitional flow rate (qt) to overload flow rate (qs)
WORKING CONDITION
Water temperature:≤40ºC for cold water meter
Working pressure:≤1.6Mpa