Hrf216-07 Hot Air Rubber Removal Furnace
ISO
Vertical
Industrial
Electric Holding Furnace
Ceramic Drying
Electric
Air
600*600*600mm(W*H*D)
Chitherm
Wooden Packaging
1300*1710*1800mm(W*H*D)
China
8514101000
Product Description
1. Applications:
Mainly used for binder burning out(BBO) process of electronic components, ceramic substrates. 
2. Mainly Specifics:
- Rated Temp: 600ºC
- Max Temp: 650ºC
- Effective Dimensions: 600 × 600 × 600mm(W×H×D)
- Heating Method: Stainless Steel Heater
- Process Atmosphere: Air
- Temperature Control Stability: ±1ºC, with PID parameter self-tuning function
- Temperature Uniformity: better than ±5ºC (insulation 1 hour at 400ºC test)
- Thermocouple: Type K
- Temperature control points: 1
- Temperature measurement points: 1 point
- Process Steps: 4 × 16 steps
- Exhaust: One exhaust port on top
- Alarm System: over temperature, thermocouple failure and other abnormal conditions will activate sound and light alarm protection
- Max Heating Power: 24kW
- Insulation Power: ≤ 12kW
- Surface Temperature Rise: ≤ 35ºC
- Weight: about 1000kg
- Furnace Dimensions: about 1300×1710×1800mm (W×H×D);
- Appearance Color: light gray
3. Delivery List | |||
Item | Note | QTY | |
Basic Compositions | Dryer | 1 PC | |
Certificates of Inspection | Dryer and major purchased components | 1 Set | |
Technical Documents | Manual instructions, technical documents of major purchased components, etc | 1 Set | |
Key Parts | Heating Elements | Stainless Steel Heater | 1 Set |
Thermocouple | WATLOW/THERMOWAY, Type K | 1 PC | |
Air circulator | Water cooling fan | ||
Temperature Controller | 1 Set | ||
Monitor | Touch screen | 1 Set | |
Spares | SSR | 1 PC |
4. Facility Requirements
4.1 Environmental conditions: Temperature 0 - 40ºC, humidity ≤ 80% RH, no corrosive gas, no strong
airflow disturbance.
4.2 Process air conditions: clean compressed air, pressure 0.2 - 0.4Mpa, gas consumption 3-7m3 /h.
4.3 Ventilation system: non-contact access to the user pumping system, pumping capacity is greater
than 10m3 /h;
4.4 Ground requirements: level, no obvious vibration, bearing capacity >300Kg/m2 .
4.5 Power conditions: capacity greater than 32kVA, 3 phases 5 lines, voltage 220/380V, frequency
50Hz(according to local situation). Live wire: yellow, green, red, neutral wire: blue, ground wire: yellow-green;
4.6 Installation site: 2000mm×3000mm×3000mm (W×H×D), installation area greater than 6m2.