Chitherm Hrf535-02n Nitrogen Drying Oven

Price $60000.00 Compare
Min Order 1 Piece
Shipping From Anhui, China
Popularity 267 people viewed
Quantity
+-
 

Hefei Chitherm Equipment Co., Ltd.

VIP   Audited Supplier 1 year
Profile Certified by SGS/BV
HRF535-02N
ISO
Vertical
Industrial
Electric Holding Furnace
Ceramic Drying
Nitrogen
850*700*900mm(W*H*D)
Chitherm
Wooden Packaging
1550*1630*1050mm(W*H*D)
China
8514101000
Product Description
1. Applications:
 
Mainly used for binder burning out(BBO)  under oxygen-free process of electronic components, ceramic substrates. 

2. 
Mainly Specifics:
  1. Rated Temp.: 200ºC
  2. Max Temp.: 300ºC
  3. Effective Dimensions: 800 × 800 × 800mm(W×H×D)
  4. Heating Method: Customized Heater
  5. Process Atmosphere: Nitrogen
  6. Temperature Control Stability: ±1ºC, with PID parameter self-tuning function
  7. Temperature Uniformity: better than ±3ºC (insulation 1 hour at 200ºC test)
  8. Thermocouple: Type K
  9. Temperature control points: 1
  10. Temperature monitoring points: 1 point
  11. Process Steps: 20 steps
  12. Exhaust: One exhaust port on top
  13. Alarm System: over temperature, thermocouple failure and other abnormal conditions will activate sound and light alarm protection
  14. Max Heating Power: 10kW
  15. Insulation Power: ≤ 5kW
  16. Surface Temperature Rise: ≤ 35ºC
  17. Weight: about 700kg
  18. Furnace Dimensions: about 1550×1630×1050mm (W×H×D);
3. Delivery List
 ItemNoteQTY
Basic CompositionsDryer 1 PC
Certificates of InspectionDryer and major purchased components1 Set
Technical DocumentsManual instructions, technical documents of major purchased components, etc1 Set
Key PartsHeating ElementsCustomized Heater1 Set
ThermocoupleWATLOW/THERMOWAY, Type K1 PC
Temperature Controller 1 Set
MonitorTouch screen1 Set
SparesSSR 1 PC

4. Facility Requirements
4.1 Environmental conditions: Temperature 0 - 40ºC, humidity ≤ 80% RH, no corrosive gas, no strong
airflow disturbance.
4.2 Process air conditions: 99.999% purity nitrogenpressure 0.2 - 0.4Mpa, gas consumption 5-15m3 /h.
4.3 Ventilation system: non-contact access to the user pumping system, pumping capacity is greater
than 15m3 /h;
4.4 Ground requirements: level, no obvious vibration, bearing capacity >300Kg/m.
4.5 Power conditions: capacity greater than14kVA, 3 phases 5 lines, voltage 220/380V, frequency
50Hz(according to local situation). Live wire: yellow, green, red, neutral wire: blue, ground wire: yellow-green;
4.6 Installation site: 2500mm×2100mm×3000mm (W×H×D), installation area greater than 5m2.