MBF40-11N
ISO
Vertical
Industrial
Electric Holding Furnace
Ceramic Sintering
Electric
Air
330*200*660mm(W*H*D)
Chitherm
Wooden Packaging
1150*1970*1460mm(W*H*D)
China
8514101000
Product Description
1. Applications:
Mainly used for electronic components, ceramic filters in high temperature binder burn off and sintering process.2. Mainly Specifics:
- Rated Temp.: 900ºC
- Max Temp.: 1100ºC
- Effective Dimensions: 330 × 200 × 660mm(W×H×D)
- Heating Method: SiC Rods
- Process Atmosphere: Nitrogen
- Temperature Control Stability: ±1ºC, with PID parameter self-tuning function
- Temperature Uniformity: better than ±5ºC (insulation 2 hours at 800ºC test)
- Thermocouple: Type N
- Temperature control points: 3 points
- Temperature measurement points: 1 point
- Process Steps: 9 steps
- Oxygen Content: ≤ 20ppm+gas supply oxygen content
- Exhaust: One exhaust port with manual adjustment
- Alarm System: over temperature, thermocouple failure and other abnormal conditions will activate sound and light alarm protection, over temperature heating power will turn off automatically
- Max Heating Power: 25kW
- Insulation Power: ≤ 10kW
- Surface Temperature Rise: ≤ 35ºC
- Weight: about 700kg
- Furnace Dimensions: about 1150*1970*1460mm (W×H×D);
- Appearance Color: light gray
3. Delivery List | |||
Item | Note | QTY | |
Basic Compositions | Furnace | 1 PC | |
Certificates of Inspection | Furnace and major purchased components | 1 Set | |
Technical Documents | Furnace specifications, technical documents of major purchased components, etc | 1 Set | |
Key Parts | Heating Elements | SiC Rods | 1 Set |
Thermocouple | WATLOW/THERMOWAY, Type N | 1 PC | |
Temperature Controller | Azbil | 1 Set | |
Monitor | Proface touch screen | 1 Set | |
Spares | SSR | 1 PC |
4. Facility Requirements
4.1 Environmental conditions: Temperature 0 - 40ºC, humidity ≤ 80% RH, no corrosive gas, no strong
airflow disturbance.
4.2 Process air conditions: 99.999% purity nitrogen, pressure 0.2 - 0.4Mpa, gas consumption 4 - 12m3 /h.
4.3 Ventilation system: non-contact access to the user pumping system, pumping capacity is greater
than 20m3 /h;
4.4 Ground requirements: level, no obvious vibration, bearing capacity > 250Kg/m2 .
4.5 Power conditions: capacity greater than 35kVA, 3 phases 5 lines, voltage 220/380V, frequency
50Hz(according to local situation). Live wire: yellow, green, red, neutral wire: blue, ground wire: yellow-green;
4.6 Installation site: 2500mm×2000mm×3000mm (W×H×D), installation area greater than 5m2.