Product Description
XMT-JK808 series intelligent temperature control instrument is a new meter to meet the market needs. The meter is controlled by single chip microcomputer, every channel setting value and some parameters can be set up independently.


Main technical specification  
1,Input(can be selected):CU50(-50~150),PT100(-80~600),K(-30~999),
E(-30~700),J(-30~900),T(199~400)
2,Measurement deviation: ≤±0.5%F·S±1B   Cold end compensating deviation: ≤±2.0ºC
3,Sampling cycle: 0.5S
4,Control cycle: relay output 2~120S , other is 2S.
5,Relay output contact capacity: AC220V/5A (resistance load) or AC220V/0.3A (perceptual load)
6,Alarm relay contact output:AC220V/1A(resistance load)
7,Driving solid relay signal output: driving electric current≥15mA, voltage≥9V.
8,Power supply: AC85V~242V, 50/60Hz
9,Working condition: temperature 0~50.0ºC, relative humidity≤85%RH, without corrode and strong electric radiation.

Panel instruction



ALM1~ALM8:The first channel to the eighth channel alarm output indicator light ( red);
OUT1~OUT8:The first channel to the eighth channel control output indicator light ( green );
CH1~CH8 key:The first channel to the eighth channel corresponding channel parameter setting key;
SET/I key:The first channel to the fourth channel function setting key;  
SET/II key:The fifth channel to the eighth channel function setting key;
 key(left):The first channel to the fourth channel shift key;  
 key(right):The fifth channel to the eighth channel shift key;
 key(left):The first channel to the fourth channel data decrease key;  
key(right):The fifth channel to the eighth channel data decrease key;
key(left):The first channel to the fourth channel data increase key;  
 key(right):The fifth channel to the eighth channel data increase key;
 

Model significance:

1.Meter faceplate and Installation dimension(mm):160×80×130;  152×76;
2.Design serial number:Eight channel independent control meter, PID and ON/OFF control can optional;
3. Alarm:'0':no set alarm; '1':one alarm ( alarm mode optional);  
4.Input signal: "8": Free exchange of the input signal
5. Main control mode: 'space': relay normally-open normally-closed contact output;
            'A':Single phase zero trigger control;     'G':Solid state relay control output
6. Suffix:'K':with 485 or RS232 Communication module interface;
        'WT':With an external printer module interface   


Connection scheme(consult):