Closed Loop Type (B2N Series) Hall Effect Current Sensor

Price $9.10 Compare
Min Order 1 Piece
Shipping From Zhejiang, China
Popularity 322 people viewed
Quantity
+-
 

Wenzhou Heyi Electrical Co., Ltd.

VIP   Audited Supplier 14 years
Profile Certified by SGS/BV
B2N
Hall Type
Analog Output
SemiConductor Integrated
Plastic
0.5G
Switching Power Supply
IP65
ISO
Customized
B2n- 0.5A/ B2n-1A/ B2n-2A/ B2n-5A/ B2n-10A/ B2n-20
0.5-20A
1-30A
400 Ohm
+-12V, +-15V
Less Than 20+ Ipx(Np/Ns)
Less Than 0.1
@ 50Hz, AC, 1min 2.5kv
DHL, TNT, FedEx...
HEYI
Green Plastic Film
CE, ISO, Rohs
Liushi, Yueqing, Zhejiang Province, China
8542390000
Product Description
B2N series current sensor is a closed loop device based on the measuring principle of the hall effect and null balance method, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC, AC or pulsed currents.
 
Electrical data (Ta=25ºC±5ºC)
 
TypeB2N-
0.5A
B2N-
1A
B2N-
2A
B2N-
5A
B2N-
10A
B2N-
20A
Unit
Rated current(Ipn)0.51251020A
Measure range(Ip)124102030A
Turns ratio(Np/Ns)30:150015:15008:16003:15002:20001:2000T
Internal resister400400400400400400Ω
Rated output@Ip=±Ipn              ±4±0.5%V
Supply voltage±12,±15V
Power Consumption≤20+ IpX(Np/Ns)mA
Zero offset voltage@Ip=0                   ≤±20mV
Offset voltage drift@ -40~+85ºC             ≤±0.5mV /ºC
Linearity@Ip=0-±Ipn              ≤0.1%FS
Response time@100A/μ S,10%-90%       ≤1μS
Galvanic isolation@ 50HZ,AC,1min            2.5KV
 
Applications
 
·AC variable speed drives
·Static converters for DC motor drives
·Battery supplied applications
·Uninterruptible Power Supplies (UPS)
·Switched Mode Power Supplies (SMPS)
·Power supplies for welding applications

CurrentdConnectedTerminal PIn Identification
10.5A-3A2-ø0.65,10

1...+15V

2...-15V

3...0V

4...Output

5.6,7...primary input current(+)

8,9,10...primary input current(-)

25A,10A2-ø0.66,9
320A4-ø1.66-7,8-9
Remarks:
1. All dimensions are in mm.
2. General tolerance ±1mm.
 
Directions for use
 
1. When the current will be measured goes through a sensor, the voltage will be measured at the output end. (Note: The false wiring may result in the damage of the sensor)
2. Custom design in the different rated input current and the output voltage are available.
 
Standards
·UL94-V0.
·EN60947-1:2004
·IEC60950-1:2001
·EN50178:1998
·SJ 20790-2000
General date
 
 ValueUnit
Operating temperature(TA)-40 to +85ºC
Storage temperature(TS)-40 to +125ºC
Mass(approx) (M)22g
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA