RPVU90
Insulated Cables
Solid
Overhead, Heating, Underground, Insulated Cables
Copper
PVC
XLPE
Round Wire
Conduit or Recognized Raceways for Services
ISO9001, CE, CCC, RoHS, VDE
Huacheng Brand
Huacheng Brand
as Customer Requirement
14awg-1000mcm
China-Mainland
8544492100
Product Description
Copper Cables XLPE Coils and Drums Insulated 14AWG-1000mcm China Cable Rpv
Photovoltaic Wire RPVU90
Single-conductor thermoset-insulatied cable that are rated 1000V or 2000V,suitable for AC and DC systems.
Standards applied
CSA C22.2 NO.38 Thermoset-insulated wires and cables

RPVU90 1000/2000V Copper
Range and Dimensions


Photovoltaic Wire RPVU90
Single-conductor thermoset-insulatied cable that are rated 1000V or 2000V,suitable for AC and DC systems.
Application
•Stranded conductor XL insulated solar cable.
•For use in solar power applications per Canadian Electrical Cod
•Rated 90ºC for exposed or concealed wiring in wet or dry locations
Construction
Conductor : Stranded copper conductor or stranded aluminium conductor (AA8000)
Insulation : XLPE insulation
Marking sample : HUATONG CABLES C(UL) E365883 RPVU90 10AWG(5.26mm2) 2000V CU/XLPE 90ºC DRY OR WET (-40C) FT1 DIR BUR SUN RES 03/2023 ****M
Rated voltage : 1000/2000V
Core Identification
Insulation : Black or Red or White
*other colours available on request
Installation recommendations
Min. Bending Radius during Installation : 12xD (D is diameter of cable)
Min. Bending Radius Fix Installed : 10xD (D is diameter of cable)
Max. Conductor Operating Temperature : 90°C
•Stranded conductor XL insulated solar cable.
•For use in solar power applications per Canadian Electrical Cod
•Rated 90ºC for exposed or concealed wiring in wet or dry locations
Construction
Conductor : Stranded copper conductor or stranded aluminium conductor (AA8000)
Insulation : XLPE insulation
Marking sample : HUATONG CABLES C(UL) E365883 RPVU90 10AWG(5.26mm2) 2000V CU/XLPE 90ºC DRY OR WET (-40C) FT1 DIR BUR SUN RES 03/2023 ****M
Rated voltage : 1000/2000V
Core Identification
Insulation : Black or Red or White
*other colours available on request
Installation recommendations
Min. Bending Radius during Installation : 12xD (D is diameter of cable)
Min. Bending Radius Fix Installed : 10xD (D is diameter of cable)
Max. Conductor Operating Temperature : 90°C
Standards applied
CSA C22.2 NO.38 Thermoset-insulated wires and cables

RPVU90 1000/2000V Copper
Range and Dimensions
Size | NO. OF STRANDS | Diameter of conductor | Insulation Thickness | Approximate O.D. | Approximate Weight |
AWG/kcmil | mm | mm | mm | kg/km | |
12 | 7 | 2.26 | 1.52 | 5.3 | 58 |
10 | 7 | 2.87 | 1.52 | 5. | 80 |
8 | 7 | 3.61 | 2.03 | 7.7 | 131 |
6 | 7 | 4.52 | 2.03 | 8.6 | 168 |
4 | 7 | 5.72 | 2.03 | 9.8 | 247 |
3 | 7 | 6.40 | 2.03 | 10.5 | 301 |
2 | 7 | 7.19 | 2.03 | 11.3 | 368 |
1 | 19 | 8.18 | 2.41 | 13.0 | 470 |
1/0 | 19 | 9.19 | 2.41 | 14.0 | 577 |
2/0 | 19 | 10.00 | 2.41 | 14.8 | 707 |
3/0 | 19 | 11.60 | 2.41 | 16.4 | 877 |
4/0 | 19 | 13.00 | 2.41 | 17.8 | 1085 |
250 | 37 | 14.20 | 2.79 | 19.8 | 1295 |
300 | 37 | 15.50 | 2.79 | 21.1 | 1533 |
350 | 37 | 16.80 | 2.79 | 22.4 | 1770 |
400 | 37 | 17.90 | 2.79 | 23.5 | 2005 |
450 | 37 | 19.00 | 2.79 | 24.6 | 2241 |
500 | 37 | 20.00 | 2.79 | 25.6 | 2475 |
550 | 61 | 21.10 | 3.18 | 27.5 | 2747 |
600 | 61 | 22.00 | 3.18 | 28.4 | 2981 |
650 | 61 | 22.90 | 3.18 | 29.3 | 3216 |
700 | 61 | 23.70 | 3.18 | 30.1 | 3450 |
750 | 61 | 24.60 | 3.18 | 31.0 | 3685 |
800 | 61 | 25.40 | 3.18 | 31.8 | 3919 |
900 | 61 | 26.90 | 3.18 | 33.3 | 4382 |
1000 | 61 | 28.40 | 3.18 | 34.8 | 4846 |