DMF-1
1 Year
1 Year
±0.2%~±0.15%, ±0.2-0.5%
Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas
DN1.5~DN200
Tube/Flange
Industrial Production
Coriolis Mass Flow Meter
Liquid
Atomic Physics
JIS, DIN, ANS, GB, CE, RoHS, ISO
2kg/H~500t/H
0~32MPa
-50º C~ +350º C
4-20mA Current Signal of Flow, with Load Resistanc
24VDC
Ex(Ib)II Bt2-T5
0.1s~5s, Adjustable
1year
Global
U-ideal
Wooden Case or Carton
ANSI JIP DIN JS and others
Tianjin, China
90261000
Product Description
Introduction
UCMF-1-Series Coriolis Mass Flow Meters' measuring principle is based on the controlled generation of Coriolis forces. The measurement would not be affected by the pressure, temperature, viscosity, density, etc. And the compensation calculation is not required. The structure contains two parts: Sensor & Transmitter. The Coriolis Mass Flow Meters are designed and manufactured based on the national standard of safe explosion proof. The Explosion- proof standard is EX d ib II C T5 Gb.

The mass flow meter does not measure the volume per unit time (e.g., cubic meters per second) passing through the device; it measures the mass per unit time (e.g., kilograms per second) flowing through the device. The accuracy of the Coriolis Mass Flow Meters is ±0.1%~ ±0.2%. The application range is large. (It could be used to measure all sorts of all sorts non-newtonian fluid, slurry, suspensions, high viscosity fluid, etc.) The requirements for the installation are low. (The straight pipe requirements in front of and behind the Coriolis Mass Flow Meters are low.) They are more reliable, stable, and the maintenance level is low.
Technical Parameters
Applications | Suitable for Liquid, Gas, Liquid- Solid, Gas- Solid, Liquid- Gas Mass Measurement or volume measurement |
Material of the Measurement Pipeline | SS 316L/ HC Hastelloy |
Pressure | Please refer to the chart shown above. Special orders would be placed for high pressure. |
Medium Temperature | -50ºC~+150ºC; (Highest Temperature: +350ºC; Lowest Temperature: -300ºC could be special ordered.) |
Environment Temperature | Sensor:-40ºC~+150ºC; Transmitter:-20ºC~ +70ºC |
Flow Rate Measurement Accuracy | ± 0.2% ,± 0.1% optional |
Density Measurement Accuracy | ±0.002g/cm³,±0.001g/cm³ optional |
Repeatability | ±0.10% Flow Rate ±[½(Zero Point Stability/Flow Rate)×100]% Flow Rate |
Output Signal | 4~20mA Load Resistance <500Ω(Instantaneous or Density optional); 0~10kHz Instantaneous Flow Rate Pulse Signal; Standard RS 485 Communication |
Explosion- Proof Symbol | EX d ib II C T5 Gb |



If the above model is not satisfying, please check the following:
Model | Nominal Size (mm) | Flow rate (kg/hr) | Stability zero, kg/h | Rated Pressure (MPa) | NW (KG) | GW (KG) | ||
0.2% | 0.15% | 0.1% | ||||||
UICMF-003 | 3 | 0~96~120 | 0.018 | 0.012 | 0.012 | 40 | 8 | 19 |
UICMF-006 | 6 | 0~540~660 | 0.099 | 0.066 | 0.066 | 20 | 12 | 22 |
UICMF-008 | 8 | 0~960~1200 | 0.18 | 0.12 | 0.12 | 20 | 12 | 23 |
UICMF-010 | 10 | 0~1500~1800 | 0.27 | 0.18 | 0.18 | 20 | 11 | 24 |
UICMF-015 | 15 | 0~3000~4200 | 0.63 | 0.42 | 0.42 | 20 | 12 | 25 |
UICMF-020 | 20 | 0~6000~7800 | 1.17 | 0.78 | 0.78 | 16 | 20 | 34 |
UICMF-025 | 25 | 0~10200~13500 | 2.025 | 1.35 | 1.35 | 16 | 21 | 35 |
UICMF-032 | 32 | 0~18 000~24 000 | 3.6 | 2.4 | 2.4 | 16 | 27 | 45 |
UICMF-040 | 40 | 0~30 000~36 000 | 5.4 | 3.6 | 3.6 | 12 | 35 | 55 |
UICMF-050 | 50 | 0~48 000~60 000 | 9 | 6 | 6 | 12 | 40 | 60 |
UICMF-080 | 80 | 0~120 000~160 000 | 24 | 16 | 16 | 8 | 90 | 150 |
UICMF-100 | 100 | 0~222 000~270 000 | 40.5 | 27 | 27 | 8 | 170 | 245 |
UICMF-150 | 150 | 0~480 000~600 000 | 90 | 60 | 60 | 6 | 255 | 360 |