010
Free Spare Part Replacment
1year
Jqyjp100
Customized
Portable
FCC, CE, RoHS
O2
Electrochemical Gas Analyzer
jiuyuan
Carton Packaging
China
Product Description
The main purpose of this device is to monitor the water ingress situation in the cargo hold. When water enters the cargo hold, the device will sound an alarm and flash a light to alert the duty personnel to take appropriate action.
The QYJP100 monitor is a cabin water level monitoring and alarm system for ships. Its technical and performance indicators comply with SOLAS Chapter XI/12 and 13 amendments, as well as CCS (2003 No. 004 Circular) regulations. The water level detector meets the performance requirements of MSC77. The sound and light alarm meets the requirements of IMO "1995 Alarm Devices and Displays Rules" and is considered one of the more advanced products domestically.
Technical Parameters:
(1) The operating voltage range of this device is AC110V ± 15% or AC220 ± 15%, frequency 50HZ-60HZ, power consumption is approximately 30W, with a backup power supply. System power supply unit: DC + 24V, water level measurement accuracy is less than ±10%, detection water depth range: 0-20m.
(2) Operating Environment: Operating temperature: -40~70°C (sub-monitoring card), 0~50°C (upper computer). Relative humidity: less than 90% (at an ambient temperature of 20°C).
(3) Electromagnetic Compatibility: Surge immunity complies with IEC801-5 standard, conducted and radiated interference complies with GB9254A standard.
Product Introduction
The PS-1 signal transmitter is to convert 0~3V reference potential into 4~20mA industrial standard signals, and then send to the control center for monitoring.
Conditions of use
Working environment temperature:-20~+40ºC
Working environment humidity:≤95%
Electrical properties:
supply voltage: DC 24V
Input reference signal:0~3V
Output industrial standard signal:4~20mA
Load impedance:0~600Ω
Signal conversion accuracy:≤1%