Order No.: CTH2 277-0PN36
Specification: Profinet slave module, only supports RT real-time communication mode, can expand up to 8 CTH200 series IO modules (excluding CAN module, operation control module, weighing and other special modules)
1,Profinet bus communication rate 100Mbps,the maximum communication distance up to 100m between two slave module(100BASE-TX).
2,The topological structure support star,tree,linear,ring structure.
3,Each slave module allow to extend 8 I/O module(digital module,analog module,temperature module,PID module.but CAN module,motion control module,weighting module are not include).
4,Support Siemens Profinet master station,Siemens Smart200,Siemens S7-300,Siemens S7-1200,Siemens S7-1500.Support Modbus RTU,PPI,Mitsubishi,Omron,Delta protocol.
5,Programming software TIA Portal V13 and above version.
Profinet architecture diagram
Performance Parameters
Physical Features | |
Dimension(W×H×D) | 71×80×62 mm |
Power Consumption | |
Rated voltage input | 24V DC |
Voltage range | 20.4V~28.8V DC |
Current input | 0.8A |
Bus power voltage | +5V DC |
Bus power current | 1.1A |
Isolation | The external power supply is isolated from the system power supply |
Power protection | provides reverse connection protection and surge absorption |
LED Indicator | |
24V Indicator(Green) | ON = 24VDC power |
OFF = 24VDC no power | |
SF Indicator(red) | ON = extend I/O Bus failure or PROFINET module failure |
OFF = no fault | |
BF Indicator(red) | ON = PROFINET Bus communication failure (no connection to switch, no network detected) |
Blinking=Hardware configuration is inconsistent | |
OFF = no fault | |
MT Indicator(yellow) (maintenance indicator ) | ON = Loss of synchronization |
OFF = no fault | |
P1R/P2Rport Indicator(green) | ON = There is a connection to the switch /PN master station |
OFF = There is no a connection to the switch /PN master station | |
P1R/P2RportIndicator(yellow) | ON = received data |
OFF = no received data |
Expansion I/O | |
Maximum support module | 8(digital module,analog module,temperature module and PID module,other moudle is not included) |
Protocol | CTH200 PLC 4MHZ Bus protocol |
Maximum IO each station | Analog IO up to 64AI/32AQ Digital IO up to 256DI/256DQ |
Topological structure | support star,tree,linear,ring structure. |
PROFINET port | |
Communication port | 1*dual RJ45 port |
Data transmission rate | Ethernet speed rate 10Mbps |
PROFINET speed rate100Mbps | |
Support Ethernet | ping,arp,(SNMP)/MIB-2,LLDP |
Real time performance | RT: Supported, minimum cycle 1ms, not IRT supported |
The third partPROFINET master station | Support |
Maximum distance | 100m(100BASE-TX) |
Topological structure | support star,tree,linear,ring structure. |
Isolation | Communication port isolation |
Hardware configuration function | |
File type | PROFINET GDS file XML format |
The third partPN master station | Add CTH 277-0PN32 then support 8pcs expansion model |
digital module,analog module,temperature moduleand PID module,other moudle is not included |
External Power Interface Definition

RJ45 Network Port Definition

Installation specifications

When installing and disassembling the CTS7/CTH2 277-0PN36 module, appropriate safety measures must be taken in advance and the power supply to the CTS7/CTH2 277-0PN36 module must be confirmed to be cut off.
The CTS7/CTH2 277-0PN36 module can be installed on both the control cabinet backplane and standard DIN rails; It can be installed horizontally or vertically.
Installing panels
1) Position and drill holes according to the size requirements in Figure 4-6;
2) Secure the module to the backplane with appropriate screws;
3) If an expansion module is used, connect the flat cable of the expansion module to the expansion port under the front cover.
DIN rail installation
1) Fix the guide rail on the back panel;
2) Open the DIN clip at the bottom of the module and clip the back of the module onto the DIN rail;
3) If an expansion module is used, connect the flat cable of the expansion module to the expansion port under the front cover;
4) Rotate the module close to the DIN rail and close the DIN clip;
5) Carefully check whether the DIN clamp on the module is tightly fixed to the DIN rail;
6) To avoid module damage, do not directly press the front of the module, but press the part of the installation hole
Attention: When the module is used in environments with high vibration or when installed vertically, DIN rail stops should be used. If the system is in a high vibration environment, using a backboard installation method can achieve a higher level of vibration protection.









Q1.What's the payment term?
A. We accept TT,LC,Western Union,Paypal.
Q2.What is the delivery time?
A. It depends on order quantity,usually it will take about 3-5 days for sample production.
Q3.What's the package used for?
A. For the small capacity,will use carton,but for big capacity,we should use honeycomb carton and pallet or wooden case for protection.
Q4.Would you accept to use our logo?
A.It's no problem,we accept OEM service.
Q5.What's your production capacity for one month?
A. Our month capacity can reach near 500-3000pcs for the most of our model.
Q6.Where is your market?
A. Our products are popular in Australia,South America,Philippines,Italy, America, Pakistan and so on.Some of them are our regular customers and some of them are developing. We hope you can join us and make mutural benifit from our cooperation.
Q7. What kind of certificates you have?
A. Our company has ISO9001,CE, RoHS,SGS etc.
Logo
Please offer us your own high resolution logo in JPG format,there should be two colors at most in the logo and there should be no gradient effect in the logo.
2. Label
Please offer us your own model numbers.
Lead Time
1.Sample orders will be delivered from our factory within 3-5 working days.
2.General orders will be delivered from our factory within 7-15 working days.
3.Large orders will be delivered from our factory within 45 working days at most.
Shipment
1.By EMS,DHL,FedEx,TNT,UPS or other Express.
2.By our forwarding agent(by Air or by Sea).
3.By your own forwarding agent.