Covered Conductors Type CCT 6.35/11kv, 12.7/22kv, 19/33kv (AAAC/XLPE) Overhead Cable Aluminium Alloy Conductor, Weather Resistantxlpe Insulation, Covered Condu

Price $10.00 Compare
Min Order 1000 Meters
Shipping From Shanghai, China
Popularity 449 people viewed
Quantity
+-
 

Qifan Cable Co., Ltd

VIP   Audited Supplier 1 year
Profile Certified by SGS/BV
CCT
Insulated
Stranded
Overhead
Aluminum
HDPE or XLPE
XLPE
Round Wire
Power Transmission
ISO9001, CE, CCC, RoHS, VDE
QIFAN
Black
No
No
15days
Qifan
Drum or Customized
as per requirements
China
8544601290
Product Description
Product Parameters


    Established in 1994, Shanghai Qifan Cable Co., Ltd. (stock code 605222) has now developed into an innovative wire and cable enterprise with strong research and development capacities after 30 years in the industry. The company has 4 large-scale production bases in Shanghai Jinshan, Anhui Chizhou, Hubei Yichang and Shanghai Minhang. It has set up two direct sales centers in Shaanxi Xi'an,and Fujian Sanming. More than 230 contracted dealers are distributed in various provinces and cities in China. The company currently has more than 4500 employees, and has more than 3,000 sets of advanced wire and cable R&D, production and testing equipment at home and abroad. The annual production capacity can be more than 30 billion yuan.
The company has obtained more than 140 national invention patents and utility model patents and has established close industry-university-research cooperation relations with Harbin University of Science and Technology, Shanghai Jiaotong University, Dalian University of Technology, Henan Institute of Technology and other universities. The company ranks among the top 10 competitiveness enterprises in the wire and cable industry of China, the top 100 Shanghai enterprises, the top 500 national manufacturing companies. The company has been certified to ISO9001 quality management system, ISO14001 environmental management system, ISO45001 occupational health and safety management system, ISO50001 energy management system, and integration of informatization and industrialization management system, and won the title of national green factory. The company's products have successively passed China Compulsory Certification (CCC), mining product safety mark certification, China Classification Society certification, TLC certification, TUV certification, CE certification, UL certification, etc.
   The company's products cover four categories: power cables, wire and cable for electrical equipment, communication cables and bare wires. They include plastic insulated land and submarine power cables of 500kV and below, rubber insulated wire and cable of 66kV and below, aerial insulated cables, overhead conductors, mining cables, shipboard cables, aeronautics and aerospace cables, nuclear cables, watertightness cables, fire resistant cables, high temperature resistant cables, extreme cold resistant cables, offshore topside cables, control cables, computer cables, photovoltaic cables, turbine and wind farm cables, trailing cables, robot cables, elevator cables, electric vehicle cables, prefabricated branched cable, building wire, coaxial cables, LAN cables, a total of nearly 30 product series with nearly 4,000 types and more than 50,000 specifications. The company's products have been widely used in water conservancy, electric power, home improvement, rail transit, construction engineering, aerospace, new energy, communications, ships, intelligent equipment, metallurgy, petrochemical, port machinery, marine engineering, industrial and mining and other fields, and exported to more than 50 countries and regions such as Australia, Germany, the United States, the Philippines, Mongolia, Singapore, Yemen, and the United Arab Emirates.
30 years of hard work and devotion makes the extraordinary Qifan today. The company is constantly promoting informatization, technology, branding and green construction.
Qifan Cable: connecting the world to the future! 

Covered Conductors

Covered conductors are conductors covered with insulation material but without conductor or insulation screens. They must be used in
a similar manner to open wire 11 to 33kV bare overhead systems with exceptions described in the Australian Standard for Covered Conductors, AS/NZS 3675. Two main types of Covered Conductors are available: CC and CCT. Our technical staff can provide detailed recommendations on the most suitable installation conditions and fittings for both systems.

Covered Conductors

CC covered conductors have a covering with a minimum average thickness of 2.0mm for use on all working voltages up to and including 19/33kV. CC can withstand intermittent contact with conductive material between phases or to ground, e.g. trees and branches, but should not remain in permanent contact.
Conductors Conductors are available in aluminium alloy 1120 which was developed by us  with technology obtained originally under license from Sweden in 1978. Alloy 1120 has excellent mass-tension- conductance properties and in Australia and Sweden has taken the place of other types of aluminium alloys.
Water blocking We pioneered the development of water blocking for covered conductors in Australia. Extensive research in material processing and techniques has enabled the manufacturing of covered conductors that are water blocked with a special material meeting all the test requirements of AS/NZS 3675.
Covering The conductors are covered with a track resistant UV stabilised XLPE. CC are marked on the external surface with "CC" ,year of manufacture, and conductor material. They are also marked with sequential six-digit numbers at 1-metre intervals, with the lowest number at the inner end of the drum.
Operating temperatures
  1. Normal operation 80°C
  2. Emergency operation 100°C
  3. Short circuit operation 210°C (5s max); (250°C for aluminium clad steel)

Full Thickness Covering (CCT)

CCT covered conductors have a specified thickness of covering for each of the nominated working voltages. While still required to operate under similar principles to a bare wire or CC system, they have electrical and mechanical characteristics which permit them to remain in contact with tree limbs for an extended period dependent on abrasive characteristics of the tree, frequency and strength
of prevailing winds and operating temperature. CCT show better performance in polluted environments. They are suitable for use in 'spacer cable' systems and in the Insulated Unscreened Conductor (IUC) systems.
Conductors Conductors are available in aluminium alloy 1120.

Water blocking The conductors are water blocked with a special material meeting the test requirements of AS/NZS 3675.
Covering The conductors are covered with a track resistant UV stabilised XLPE or with an inner layer of non-UV stabilised XLPE, and an outer layer of UV stabilised High Density Polyethylene (HDPE). In the latter case, the average thickness of HDPE is not
more than 40% of the specified minimum average thickness, and not less than 1.0mm. CCT are marked on the external surface with "CCT," "Olex," year of manufacture, and conductor material. They are also marked with sequential six-digit numbers at 1-metre intervals, with the lowest number at the inner end of the drum.

XLPE covered aerial cables to AS/NZS 3675. Waterblocked aluminium alloy 1120 conductors. Also available with XLPE/HDPE covering.
Physical Data
 
NominalNominal andNominalAverageNominalApproximateProduct
conductornominalconductorinsulationdiametermasscode
areadiameter of wiresdiameterthicknessover insulation  
mm2no/mmmmmmmmkg/km 
6.35/11kV      
407/2.758.43.415.8260UJAJ12AA001
807/3.7511.43.418.8400UJAJ87AA001
1207/4.7514.53.421.9580UJAJ90AA001
18019/3.5017.73.425.0790UJAJ73AA001
24019/4.0120.23.427.71000UJAJ83AA001
12.7/22kV      
807/3.7511.45.523.0530ULAJ87AA001
1207/4.7514.55.526.1720ULAJ90AA001
18019/3.5017.75.529.2960ULAJ73AA001
19/33kV      
807/3.7511.48.028.0710UNAJ87AA001
1207/4.7514.58.031.1930UNAJ90AA001
18019/3.5017.78.034.21190UNAJ73AA001

Performance Data
Nominal     DC             AC            Inductive  Three-phase Continuous current rating, A        Earth fault Minimum   Min.                 Rec. tension                Modulus     Coeff.
conductor arearesist. at 20°Cresist. at 50Hz 80°Creactance at 50Hzvoltage drop at 50Hz 80°C
Still

1m/s

2m/s
current rating for 1sbending radius (installed)breaking load of cableHighest everyday tensionMax working tensionof elasticityof linear expansion
mm2Ù/kmÙ/kmÙ/kmmV/A.mairwindwindkAmmkNkNkNGPa10-6/°C
6.35/11kV              
400.7130.8800.3311.631151902153.72409.91.494.966523.0
800.3830.4730.3110.9811702803106.828017.62.648.806523.0
1200.2390.2950.2950.72323037042011.033027.14.0713.66523.0
1800.1630.2020.2790.59729547053016.138041.76.2620.96523.0
2400.1240.1540.2710.53935055063021.242052.37.8526.26523.0
12.7/22kV              
800.3830.4730.3110.9811702652956.835017.62.648.806523.0
1200.2390.2950.2950.72323035539511.039027.14.0713.66523.0
1800.1630.2020.2790.59729545050016.144041.76.2620.96523.0
19/33kV              
800.3830.4730.3110.9811752552806.842017.62.648.806523.0
1200.2390.2950.2950.72323034037511.047027.14.0713.66523.0
1800.1630.2020.2790.59729543047516.151041.76.2620.96523.0