SC (B) H15
Power
Three
Core-type Transformer
Dry-type Transformer
Two-winding Transformer
ISO9001, CCC
Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer
Low Frequency
Ring
Bo Lian
Dyn11 Yyn0
30/630kVA
Silicon Steel
0.4 Kv/10kv
Dry-Type Transformer
BO LIAN
Wooden Case or Pallet
according to the customization
China
Product Description

Overview:
Our company produces 10kV amorphous alloy dry-type transformer. With low loss. Low loss. Low noise. Low temperature rise. Low local discharge. Short-time super nameplate running capacity, withstand short-circuit capacity, a good solution to the urban enterprises and institutions in the supply of electricity in the fire-fighting pressure, amorphous alloy dry-type transformers can be widely used in high-rise buildings, commercial Zhongxing, airports, stations. Wharf, underground, factories and underground distribution stations



Transformer TypeTransformer | Resin Cast Dry Type |
Model | SCB10 |
Number of Phase | Three Phase |
Winding Type | Two Winding |
Winding Material | Aluminum/Copper |
Rated Capacity | 50/2500kVA |
High Voltage | 10/11kV |
Low Voltage | 0.4kV |
Tapping Ran | ±2x2.5% |
Impedance Voltage | 4% |
Load Loss (120°C) | 1kW |
No-load Loss | 0.27kW |
No-load Current | 2% |
Frequency | 50/60Hz |
Connection Group | Yyn0/Dyn11 |
Cooling Method | ANAF |
Insulation Class | F |
Thermal Class | F1 |
Operation Altitude | ≤1000m≤ 1000 m |



>>Technical Performance Parameters
1.Number of phases:3 phases;Frequency:50Hz
2.Partial discharge:not more than 10pC
3.Insulation heat-resistant grade:F grade
4.Average temperature rise of winding: not more than 100K
5.Noise level:Sound level in accordance with GB/T22072-2008
>>Product features
Safe, flame retardant and fireproof, no pollution, can be directly installed in the load centre;
High mechanical strength, strong short-circuit carrying capacity, safe and reliable operation;
Maintenance-free, easy installation, low comprehensive running cost;
Good anti-lake performance, can operate normally at 100% temperature, and can be put into operation without pre-drying after shutdown;
Low loss, low local discharge, low noise, strong heat dissipation ability, and it can run at 150% of rated load under forced air-cooling condition;
Equipped with perfect temperature protection control system, providing reliable guarantee for the safe operation of the transformer;
The remarkable feature of non-product alloy dry-type transformer is that the no-load loss is small while the economic operation and load rate are relatively low;
It is especially suitable for industrial and mining enterprises whose load rate is in the range of 50%-80% and three-shift system is implemented;
Amorphous alloy transformer is very favourable to the reliable operation of power distribution equipment, energy and operation cost saving;
Amorphous alloy dry-type transformer has low loss, less heat generation, low temperature rise and stable operation performance;
amorphous Taigin dry-type transformer has strong overload capacity, safe and reliable, strong corrosion resistance, maintenance-free, can be widely used in national defence, basement, high-rise buildings and other places requiring uninterrupted power supply.




Transformer Type:
Rated Capacity: kVA
Phase: ( )Three Phase ( )Single Phase
Frequency: ( )50Hz ( )60Hz
Rated Voltage (HV/LV): kV / kV
Tapping Range: ± x %
Insulation Level: LI AC / LI AC
Vector Group: ( )Dyn11 ( )Yyn0 ( )Other
Short-circuit impedance: Uk= %
Service conditions: Altitude: m
Ambient temperature: ºC
Cooling Method: ( )ONAN ( )ONAF
Oil labeling:
Quantities ordered and time of delivery:
Other requires:
(If you have, It will be better send us technical specification/date documents.)