Product Description
Sintered porous bricks, crafted from premium coal gangue shale, boast an impressive porosity of 28% or more, featuring numerous small-sized pores. These superior bricks are primarily utilized for load-bearing walls and adhere rigorously to the GB13544-2011 standard. They stand out with exceptional attributes such as high alkalinity resistance, formidable seismic performance, superior strength, impressive wear and compression resistance, lightweight nature, and excellent insulation properties. Our innovative high-hole design enhances energy efficiency by 45%, maximizes the building's usable area, accelerates construction speed, and reduces mortar usage. Remarkably, when employed on exterior walls, these bricks require no additional *** prevention or reinforcement measures and can be directly plastered, substantially cutting project costs and ensuring a smooth, ***-free surface over time. Sintered porous bricks represent the pinnacle of modern wall materials, making them the ultimate choice in contemporary architecture.
 China National Inspection and Testing Holding Group Xi'an Co., Ltd
National Building Materials Industry Wall and Roof Material Quality Supervision, Inspection and Testing Center
 Inspection report
Number:X12403067                                          
Serial NumberInspection itemsStandard requirementsInspection resultsSingle conclusionInspection basis
Allowable size deviation,

mm
Sample mean deviationlong
wide
high
±2.5
±2.0
±1.5

+1.1
+0.8
+1.0
qualifiedGB/T13544-2011
6.1
GB/T2542-2012
4
sample
range
long
wide
high
≤8.0
≤7.0
≤6.0
2.0
3.0
2.0
Appearance quality, blockThe number of non-conforming products allowed in one sampling of appearance quality≤7qualifiedGB/T2542-2012
5
Density
Grade
Density,kg/m³1100~12001180  1200 level
  qualified
GB/T2542-2012
9
Strength
Grade
compressive strength,
MPa
average value≥15.016.6 MU15
qualified
GB/T2542-2012
7
Standard value≥10.014.1 
Pore structure and porositypassRectangular strip hole or rectangular holeRectangular holequalifiedGB/T2542-2012
13

Hole size,

mm
Hole width dimension≤1311 
Hole length dimension≤4028 
Minimum outer wall thickness,mm≥1213 
Minimum rib thickness,mm≥5
porosity,%≥2832 
Hole arrangement1. All hole widths should be equal, and the holes should be arranged in a unidirectional or bidirectional staggered manner
2. The arrangement of holes should be symmetrical vertically and horizontally, evenly distributed, and the length dimension of the hand held holes must be parallel to the surface of the brick
meet a requirement
scumEach brick or block is not allowed to have severe frostingSlight frostingqualifiedGB/T2542-2012
11
lime blowing1. For explosive areas with a size greater than 2mm and less than or equal to 15mm, each group of bricks and blocks shall not exceed 15 locations, with no more than 7 locations exceeding 10mm
2. Explosive areas with a damage size greater than 15mm are not allowed to occur
Destroy 10 explosive areas with a size of 2mm~10mm.qualifiedGB/T2542-2012
10

Serial NumberInspection itemsStandard requirementsInspection resultsSingle conclusionInspection basis
Weathering resistance performance5-hour boiling water absorption rate,%average value≤2119 qualifiedGB/T2542-2012
12
Maximum value≤2321 
Saturation coefficientaverage value≤0.780.72 
Maximum value≤0.800.75 
Underfired bricks (blocks) and crispy bricks (blocks), blocksInsufficient fire bricks (blocks) and crispy bricks (blocks) are not allowedqualifiedGB/T13544-2011
6.8
GB/T2542-2012
5
10 Radioactive nuclide limitinternal exposure index Ir≤1.00.4 The main building materials are qualifiedGB6566-2010
external exposure index I≤1.30.8 

Message Type