Customized 90A AC 220V Coil Single Phase High Power Latching Relay for Control Panel

Price $2.00 Compare
Min Order 1 Piece
Shipping From Shanghai, China
Popularity 431 people viewed
Quantity
+-
 

IVY METERING CO., LTD.

VIP   Audited Supplier 7 years
Profile Certified by SGS/BV
IM901
Electromagnetic Relay
Household Appliances Relay, Energy Meter, Lighting Control, Industrial Control
1
Ac
1
High Power Relay
Enclosed Relay
Electromagnetic Type
Miniature
Electric Parameter Relay
90A, 250VAC
1A/B
Agsno2
6~48VDC
10000 Cycles
100000 Cycles
Black
20ms
IVY
Cartons/Pallet
38*30*16.5mm
Zhejiang, China
8536411000
Product Description
Basic DataDimension(mm)38×30×16.5
Weight ( g )33g
Contact Arrangement1A/1B
Contact MaterialAgSnO2
Ambient Temperature-40~+70ºC
Ambient Humidity45%~90%RH
Vibration10~55Hz,1.5mm(DA)
Specification DataNominal Voltage6~48VDC
Power ConsumptionSingle Coil:1.5W, Dual Coil:3W
Max. Switching Voltage250VAC
Max. Switching Current90A
Max. Switching Power22500 VA
Contact Resistance<2.0 mΩ
Insulation Resistance1000MΩ(DC 500V)
Dielectric Creepage10mm
Dielectric StrengthAcross Open Contact>2000VAC   1min
Coil To Contact>4000VAC   1min
Electrical Life>10,000cycles
Mechanical Life>100,000cycles
Picking-up & Release Time<=20ms
Pulse Duration>=100ms
Functional Shock Resistance10G
Destructive Shock Resistance100G
          Cautions of Latching Relay:

             1.Suggestions of relay's input
            (1)Polarity-Please check the polarity inside of our technical specification, if single coil then"+ -" or "- +"are fine,
            you can change it by one pulse.If double coil then it's necessary to confirm "-+-" or "+-+"before leaving the our factory.
            (2)Driving-Please energize the relay at our recommend pulse width, rated voltage for reliable performance, if 1.5
            times or 2 times of value or lower driving condition plz confirm with our engineer.
            (3)Relays'contact status may be changed during transportation or installation due to impact of external force,
            therefore please reset to the required status.
 
            2.Suggestions of relay's output
            (1)When choosing the relay with hard connection,please avoid the external force on load terminals during or after
            the installation.
            (2)When the relay will be connected with screw or bolts to the relays' terminals, plz make sure your connection is
            fastened and prevent relay from damages or other safety problems due to temp. Rise..
            (3)The sampling signal wires of products are limited, please do not pull or torque during installation.