J&X-Nitrogen
Chemical, Electronic, Petroleum, Pharmaceutical, Nuclear Power
New
Nitrogen Control Box/ Self-Luminous OLED Display
Gas Manufacturing
Industry
Xmb-Yw-200
0~25%Vol
Fluorescence Quenching
0.1%Vol
Exdibiict6GB
IP67
T90<20s
DC24V
16-Bit ADC Digital-to-Analog Conversion
J&X
Wooden Case
China
9027100090
Product Description
Nitrogen filling interlocking protection system
Product features:
1.Customized pretreatment: backflush, acid-base neutralization, organic matter removal, dewatering, cooling, drying, voltage stabilization, constant current, etc. of sample gas.
2.Safety: When the oxygen concentration value exceeds the first-level preset alarm value, the electromagnetic adjustment of nitrogen filling and replacement is automatically turned on until the value drops to a safe range; when it exceeds the second-level preset alarm value, the power supply is automatically cut off to stop the centrifuge.
3.Applicable explosion-proof areas: intrinsically safe explosion-proof composite instruments, meeting the requirements of strict use areas.
4.Nitrogen flow control: Equipped with a nitrogen control box, when the oxygen concentration value is within the safe range, it automatically cuts off the large flow of nitrogen to achieve a small flow of continuous supply to meet the micro-positive pressure in the centrifuge.
5.Module platform: The number of pretreatment levels and functions can be freely adjusted according to actual usage. Wider adaptability.
6.Easy maintenance: one-button calibration/calibration, tool-free disassembly and maintenance, hot-swap replacement of sensor components.
7.Intelligent display: self-luminous OLED display, multi-angle observation.

Brief description:
Nitrogen filling interlocking protection system 4-20mA signal output, RS485, HART protocol switch output 4 groups (2 groups for use and 2 groups for standby) rated voltage DC24V.
Nitrogen filling interlocking protection system 4-20mA signal output, RS485, HART protocol switch output 4 groups (2 groups for use and 2 groups for standby) rated voltage DC24V.
Technical parameters:
Model | XMB-YW-200 |
Measurement range | 0~25%VOL |
Detection principle | fluorescence quenching |
Electrochemical detection accuracy | 0.1%VOL |
Explosion-proof grade | ExdibIICT6Gb |
Protection grade | IP67 |
Response time | T90<20S |
Signal output | 4-20mA, RS485, HART protocol Switch output: 4 groups (2 groups for use and 2 groups for standby) |
Rated voltage | DC24V |
Signal acquisition | 16-bit ADC Digital-to-analog conversion |
System composition:


Application areas:
1.Enclosed centrifuge nitrogen filling protection system;
2.Nitrogen filling protection in various process processes;
3.Nitrogen filling protection system for storage tanks;
1.Enclosed centrifuge nitrogen filling protection system;
2.Nitrogen filling protection in various process processes;
3.Nitrogen filling protection system for storage tanks;
Product features:
1.Customized pretreatment: backflush, acid-base neutralization, organic matter removal, dewatering, cooling, drying, voltage stabilization, constant current, etc. of sample gas.
2.Safety: When the oxygen concentration value exceeds the first-level preset alarm value, the electromagnetic adjustment of nitrogen filling and replacement is automatically turned on until the value drops to a safe range; when it exceeds the second-level preset alarm value, the power supply is automatically cut off to stop the centrifuge.
3.Applicable explosion-proof areas: intrinsically safe explosion-proof composite instruments, meeting the requirements of strict use areas.
4.Nitrogen flow control: Equipped with a nitrogen control box, when the oxygen concentration value is within the safe range, it automatically cuts off the large flow of nitrogen to achieve a small flow of continuous supply to meet the micro-positive pressure in the centrifuge.
5.Module platform: The number of pretreatment levels and functions can be freely adjusted according to actual usage. Wider adaptability.
6.Easy maintenance: one-button calibration/calibration, tool-free disassembly and maintenance, hot-swap replacement of sensor components.
7.Intelligent display: self-luminous OLED display, multi-angle observation.