DC 24V Normal Open Motor Drive Brass Stainless Steel Mini Smart Electric Ball Valve with Actuator

Price $260.00 Compare
Min Order 1 Piece
Shipping From Zhejiang, China
Popularity 332 people viewed
Quantity
+-
 

Ningbo Leadwin International Trade Co., Ltd.

VIP   Audited Supplier 2 years
Profile Certified by SGS/BV
m-02
Oil Water Gas Acid
Brass
Thread
Electric
PN1.0-32.0MPa
Straight Through Type
Flexible Ball Valve
Flexible Ball Valve
Normal Temperature
Industrial Usage, Water Industrial Usage, Household Usage
15-50 Celsius
0-90 Celsius
10 Bar Max.
5 Sec.
IP67
AC230V Working Current 0.5 AMPS
Compact Design Light Weight Small Actuator with Fa
1/2in 3/4in 1in/3V 5V 6V 12V 24V 110V 220V DN15 DN
Medium Pressure
LEADWIN
Bubble Wrap Plus Carton
DC12V 24V AC110 220V 380V
China
Product Description


Mini Electric Ball Valve 
Compact design and light weight, small electrical actuator with fail-safe function (NC)
Product Description
PRODUCT DESCRIPTION
TECHNICAL PARAMETERS
Valve sizeNPT/BSP 1/4"3/8"1/2"3/4"1"1-1/4"(Optional)
TypeShutoff ballvalve,power is electricity
Maximum working pressure1.0MPa
Circulation mediumFluid,air
Rated voltageDC3.5V DC5V DC12V DC24V AC/DC9-24V DC9-35V
AC110-230V (Optional)
Wiring diagramCR201 CR202 CR301 CR302 CR303 CR304 CR305 CR306
CR401CR501CR502CR701CR702CR703CR704(Optional)
Open/close time≤500mA
Life time≤5S
Valve body material70000times(testingpressureis0.4MPa,medium is water)
Actuator materialBrass SS304 SS316(Optional)
Sealing materiaEngineering Plastics PPO
Actuator rotation90°
Torque force2N.m
Cable Length0.5m
Environment temperature15ºC~60ºC
Liquid temperature2°ºC~90ºC
Manual operationYesNo(Optional)
Open/close indicatorYes No(Optional)
Protection classIP67
CertificateLVD,EMC,ROHS and some SS304 valves passed NSF61-G
Company quality
management system
SO9001:2015
WIRING DIAGRAM
               CR201  WIRING  DIAGRAM(2  WIRES  CONTROL)
RD connect with positive,the BK connect with negative,the valve closed, the actuator automatically power off after in place,the valve remains fully closed position.
·BK connect with positive,the RD connect with negative,the valve open, the actuator automatically power off after in place,the valve remains fully open position
*Suitable Working Voltage:DC5V,DC12V,DC24V
*Exceeding the working voltage is forbidden
RD:Red  wire  BK:Black  wire  GR:Green  wire  BL:Blue  wire
  CR202  WIRING  DIAGRAM
  (2 wires control-"Capacitors return"in case of the power is failure)
·When SW is CLOSED,the valve OPEN,the actuator automatically power off after in place.
·When SW is OPEN,the valve CLOSED,the actuator automatically power off after in place.
*Suitable Working Voltage:DC5V,AC/DC9-24V,DC9-35V,AC110V-230V
*Exceeding the working voltage is forbidden
               CR301  WIRING  DIAGRAM  (3  WIRES  CONTROL)
·RD&GR connect with positive,BK connect with negative
·When RD&SW connected,the valve open,the actuator automatically power off after in place,valve remains fully open position
·When GR&SW connected,the valve closed,the actuator automatically power off after in place,valve remains fully closed position.
*Suitable Working Voltage:DC5V,DC12V,DC24V
*Exceeding the working voltage is forbidden
CR302  WIRING  DIAGRAM  (3  WIRES  CONTROL)
RD connect with positive,the BK &GR connect with negative
·SW CLOSED,the valve OPEN,the actuator automatically power off after in place
·SW OPEN,the valve CLOSED,the actuator automatically power off after in place.
*Suitable Working Voltage:DC9-35V
*Exceeding the working voltage is forbidden
CR303  WIRING  DIAGRAM  (3  WIRES  CONTROL)
  ·RD&GR connect with positive,the BK connect with negative.
·SW CLOSED,the valve OPEN,the actuator automatically power  off after in place.
 ·SW OPEN,the valve CLOSED,the actuator automatically power off after in place.
*Suitable Working Voltage:AC/DC9-24V,DC9-35V,AC110-230V
*Exceeding the working voltage is forbidden
CR304  WIRING  DIAGRAM  (3  WIRES  CONTROL )
·RD&GR connected with positive,and the BK connected with negative
·When RD&SW connected,the valve closed,the actuator automatically
power off after in place,remains fully closed position
·When GR&SW connected,the valve open,the actuator automatically power off after in place,remains fully open position.
*Suitable Working Voltage:DC5V,DC12V,DC24V
*Exceeding the working voltage is forbidden
  CR305  WIRING  DIAGRAM
(3 wires control-"Capacitors return"in case of the power is failure)
·RD&GR connect with positive,the BK connect with negative.
·SW CLOSED,the valve OPEN,the actuator automatically power off after in place.
·SW OPEN,the valve CLOSED,the actuator automatically power off after in place.
*The valve will be auto closed when power is failure.
*Suitable Working Voltage:AC/DC9-24V,AC110-230V
*Exceeding the working voltage is forbidden
CR306  WIRING  DIAGRAM
 
(3  wires  control-"Capacitors  return"in  case  of the  power  is  failure)
·RD&GR connect with positive,the BK connect with negative.
·SW CLOSED,the valve CLOSED,the actuator automatically power off after in place
·SW OPEN,the valve OPEN,the actuator automatically power off after in place.
*The valve will be auto closed when power is failure.
*Suitable Working Voltage:AC/DC9-24V,AC110-230V
*Exceeding the working voltage is forbidden
CR401  WIRING  DIAGRAM  (4  WIRES  CONTROL)
1,RD&BK are connected to the power,GY&GR are connected to the
controlled wiring,
2,When the SW is closed,the valve open
3,When the SW is open,the valve closed
*Suitable Working Voltage:AC110V-230V
*Exceeding the working voltage is forbidden
The control wiring with power DC5V/DC24V,when muitiple motorized valves are working in paralled,must put the same color control wiring together,otherwise the valve could working
CR501  WIRING  DIAGRAM(WITH  FEEDBACK  SIGNAL)
1.RD connect with positive,the BK connect with negative,
the valve closed,the actuator automatically power off after in place.

2.BK connect with positive,the RD connect with negative,
the valve open,the actuator automatically power off after in place.
3.GR&WT are connect when the valve open fully,YW&WT
are connect when the valve closed fully
*Suitable Working Voltage::DC5V,DC12V,DC24V
*Exceeding the working voltage is forbidden!
  CR502  WIRING  DIAGRAM
(with feedback  signal  and"Capacitors  return"in  case  of the  power  is failure)
  ·When  SW  is  closed  ,the  valve  open.the  actuator  automatically power  off  after  in  place
 ·When  SW  is  open,the  valve  closed,the  actuator  automatically power  off  after  in  place
*GR&WT  are  connect  when  the  valve  open  fully,YW  &WT  are connect  when  the  valve  closed  fully
 *Suitable    Working    Voltage:AC/DC9-24V,DC9-35V,AC110V-230V
*Exceeding  the  working  voltage  is  forbidden
  CR701  WIRING DIAGRAM
  (7 wires control with feedback signal)
---RD connect with positive
---GR connect with SW and negative wiring
---BK connect with negative wiring
---SW open.the valve open,and keeping fully open.
---SW closed.the valve closed,and keeping fully closed
----BL&GY connect with the valve's fully open signal wiring
---YW&WT connect with the valve's fully closed signal wiring
*Suitable Working Voltage:DC7-35V (wide input range voltage)
*Exceeding the working voltage is forbidden
Feedback with load ability:
The Max.off voltage:DC36V AC220V The Max.off current:≤0.4A
  CR702 WIRING DIAGRAM
(7 wires control with feedback signal )
---RD connect with positive
---GR connect with SW and negative wiring
---BK connect with negative wiring
---SW open.the valve open,and keeping fully open.
---SW closed.the valve closed,and keeping fully closed.
----BL&GY connect with the valve's fully open signal wiring
---YW &WT connect with the valve's fully closed signal wiring.
*Suitable Working Voltage:DC7-35V (wide input range voltage)
*Exceeding the working voltage is forbidden
 Feedback with load ability:
 The Max.off voltage:DC36V AC220V The Max.off current:≤0.4A
  CR702  WIRING  DIAGRAM
(7 wires control with feedback signal)
---RD connect with positive
---GR connect with SW and negative wiring
---BK connect with negative wiring
---SW open.the valve open,and keeping fully open.
---SW closed.the valve closed,and keeping fully closed.
---BL&GY connect with the valve's fully open signal wiring
---YW &WT connect with the valve's fully closed signal wiring.
*Suitable Working Voltage:DC7-35V (wide input range voltage)
*Exceeding the working voltage is forbidden
 Feedback with load ability:
 The Max.off voltage:DC36V AC220V The Max.off current:≤0.4A
 CR703  WIRING  DIAGRAM
(7 wires control with feedback signal)
·RD&GR connect with positive,the BK connect with negative.
·SW CLOSED,the valve OPEN,the actuator automatically power
off after in place
·SW OPEN,the valve CLOSED,the actuator automatically power off after in place.
·BL&GY connect with the valve's fully open signal wiring
·YW&WT connect with the valve's fully closed signal wiring.
*Suitable Working Voltage:AC/DC9-24V,DC9-35V
*Exceeding the working voltage is forbidden
 CR704  WIRING  DIAGRAM
(7 wires control with feedback signal)
·RD&BK are connected to the power,GR&BL are connected to the controlled  wiring.
·When the SWis closed,the valve open
·When the SW is open,the valve closed
·GR&WT connect with the valve's fully open signal wiring
·YW&WT connect with the valve's fully closed signal wiring.
Suitable Working Voltage::AC110V-230V
*Exceeding the working voltage is forbidden
 
CR705  WIRING  DIAGRAM
(with feedback signal and"Capacitors return"in case of the power is failure)
·RD&GR connect with positive,the BK connect with negative.

·SW CLOSED,the valve OPEN,the actuator automatically power
off after in place.
·SW OPEN,the valve CLOSED,the actuator automatically power
off after in place.
·When external power is off,the valve closed,the actuator automatically
power off after in place.
·BL&GY connect with the valve's fully open signal wiring
·YW&WT connect with the valve's fully closed signal wiring.

*Suitable Working Voltage:AC/DC9-24V,AC110-230V

*Exceeding the working voltage is forbidden
CR706  WIRING  DIAGRAM
(with feedback signal and"Capacitors return"in case of the power is failure)
·RD&GR connect with positive,the BK connect with negative.
·SW CLOSED,the valve CLOSED,the actuator automatically power
off after in place.
·SW OPEN,the valve OPEN,the actuator automatically power
off after in place.
·When external power is off,the valve closed,the actuator automatically
power off after in place.
·BL&GY connect with the valve's fully open signal wiring
·YW&WT connect with the valve's fully closed signal wiring.

*Suitable Working Voltage:AC/DC9-24V,AC110-230V

*Exceeding the working voltage is forbidden

About the"Capacitors return"function,there are twokinds of valve:normally closed and normally open.
Normally closed:

the valve will be auto closed when the power is off(without power);the valve will be auto open when the power is on.
Normally open:
the valve will be auto open when the power is off(without power);the valve will be auto closed when the power is on.
Kindly Remind:
please charge the motorized ball valve before using.


 

Related Products

About us

Unique FAQs

1.Can valve electric actuators be retrofitted to existing systems?

Yes, in many cases, valve electric actuators are designed to be retrofit-friendly. However, it's crucial to consider compatibility, sizing, and potential modifications to ensure a seamless integration into existing systems. Consulting with manufacturers and industry experts can provide guidance on retrofitting options.

2.What role do valve electric actuators play in preventing leaks and spills in industrial processes?
Valve electric actuators, with their precise control capabilities, play a crucial role in preventing leaks and spills. By swiftly and accurately modulating valve positions, these actuators contribute to the overall safety and integrity of industrial processes, reducing the risk of environmental incidents.

3.Are there advancements in remote monitoring and control of valve electric actuators?
Yes, advancements in communication technologies have facilitated remote monitoring and control of valve electric actuators. Smart actuators, equipped with connectivity features, allow operators to monitor and adjust valve positions remotely, enhancing operational flexibility and efficiency.

4.How do valve electric actuators contribute to process optimization in manufacturing plants?
Valve electric actuators contribute to process optimization by providing precise control over fluid flow. This level of control enhances the overall efficiency of manufacturing processes, ensuring consistent quality and minimizing wastage.

5.What measures are in place to ensure the cybersecurity of smart valve electric actuators?
As smart technologies become more prevalent, ensuring the cybersecurity of valve electric actuators is paramount. Manufacturers implement robust security measures, including encryption and authentication protocols, to safeguard against cyber threats and unauthorized access.

Contact Us

Want More Infomation About Electric Actuator Valve?
Inquiry Us To Get A Best Price!

Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA