RF8I/bd RF12I/bd RF16I/bd RF20I/bd
SASO, CCC, ISO9001, CE
R410A
Air Source Heat Pump
Gmcc
8.5kw, 15kw, 18kw, 20kw
Cooling + Heating+Hot Water
KONNEN
Plywood Case
CE
Zhejiang, China
8418612090
Product Description
DC INVERTER AIR TO WATER HEAT PUMP FOR COOLING, HEATING AND HOT WATER,
AIR SOURCE HEAT PUMP FOR COOLING, HEATING AND HOT WATER.
WE HAVE BOTH MONOBLOCK TYPE AND SPLIT TYPE.
WE offer OEM service!
KONNEN NEW FACTORY:

WHY CHOOSE US:

PRODUCT FEATURES:


World famous brands we cooperated for our heat pumps:

Our Projects:

Heat pump loading:




Parameters:
DC INVERTER AIR TO WATER HEAT PUMP, DC INVERTER AIR SOURCE HEAT PUMP, SPLIT HEAT PUMP, MONOBLOCK HEAT PUMP, AIR TO WATER HEAT PUMP FOR COOLING AND HEATING, AIR SOURCE HEAT PUMP FOR COOLING AND HEATING, AIR WATER HEAT PUMP.
AIR SOURCE HEAT PUMP FOR COOLING, HEATING AND HOT WATER.
WE HAVE BOTH MONOBLOCK TYPE AND SPLIT TYPE.
WE offer OEM service!
KONNEN NEW FACTORY:

WHY CHOOSE US:

PRODUCT FEATURES:


World famous brands we cooperated for our heat pumps:

Our Projects:

Heat pump loading:




Parameters:
POLESTAR series DC INVERTER MONOBLOCK TYPE HEAT PUMP FOR COOLING & HEATING & HOT WATER | ||||||
Model | RF8I/bd | RF12I/bd | RF16I/bd | RF20I/bd | RF20II/bd | |
Power Supply V/Ph/Hz | 220~240/1/50 | 380/3/50 | ||||
Rated Condition 7ºC | Heating Capacity (KW) | 8.5 | 15 | 18 | 20 | 20 |
Power Input (KW) | 2.66 | 4.36 | 5.21 | 5.88 | 5.88 | |
COP | 3.2 | 3.44 | 3.45 | 3.4 | 3.4 | |
Nominal Condition -12ºC | Heating Capacity (KW) | 5.50 | 10.50 | 12.13 | 14.5 | 14.5 |
Power Input (KW) | 2.33 | 4.40 | 5.05 | 6.01 | 6.02 | |
COP | 2.36 | 2.40 | 2.40 | 2.41 | 2.41 | |
Low Temp. Condition -20ºC | Heating Capacity (KW) | 4.70 | 9.21 | 10.52 | 12.5 | 12.5 |
Power Input (KW) | 2.47 | 4.56 | 5.18 | 6.25 | 6.25 | |
COP | 1.90 | 2.02 | 2.03 | 2 | 2 | |
Low Temp. Condition -25ºC/Water output temp. 41ºC | Heating Capacity (KW) | 3.55 | 6.82 | 8.76 | 10.35 | 10.35 |
Power Input (KW) | 2.20 | 4.21 | 5.03 | 6.02 | 6.02 | |
COP | 1.61 | 1.62 | 1.74 | 1.72 | 1.72 | |
Low Temp. Condition -25ºC/Water output temp. 50ºC | Heating Capacity (KW) | 3.19 | 6.14 | 8.08 | 9.59 | 9.58 |
Power Input (KW) | 2.28 | 4.23 | 5.69 | 6.81 | 6.81 | |
COP | 1.40 | 1.42 | 1.42 | 1.41 | 1.41 | |
Rated Cooling Condition | Cooling capacity (KW) | 7.00 | 11.50 | 12.00 | 15.00 | 15.00 |
Power input (KW) | 2.64 | 4.34 | 4.61 | 5.75 | 5.74 | |
EER | 2.65 | 2.65 | 2.60 | 2.61 | 2.61 | |
Max. power input (KW) | 4.4 | 5.2 | 6.6 | 7.1 | 8.5 | |
Max. current Without E-heater (A) | 20 | 23.7 | 30 | 32.5 | 15.5 | |
Max. Water Output Temp. Under Ambient Temp. -25ºC | 58 | 58 | 58 | 58 | 58 | |
Water resistance (kPa) | 35 | 38 | 43 | 54 | 50 | |
Noise Level dB(A) | 59.5 | 61.5 | 61.5 | 62 | 63 | |
Refrigerant | R410A | R410A | R410A | R410A | R410A | |
Water Flow | 0.95 m³/h | 1.98 m³/h | 2.06 m³/h | 2.5 | 2.5 | |
Pipe Size | DN20 | DN25 | ||||
Dimensions(mm) | 920*365*710 | 940*393*1373 | ||||
Net Weight | 60Kg | 130kg | 130kg | 140kg | 145kg | |
Testing Condition: - Rated condition: Inlet/outlet temperature 40°C/45°C. Dry bulb/wet bulb temperature 7°C/6°C - Nominal condition: Outlet temperature 41°C. Dry bulb/wet bulb temperature -12°C/-14°C - Low temperature condition: Outlet temperature 41°C. Dry bulb/wet bulb temperature -20°C/-21°C - Rated cooling: Inlet/outlet temperature 12°C/7°C. Dry bulb/wet bulb temperature 35°C/24°C |
DC INVERTER SPLIT TYPE HEAT PUMP FOR COOLING & HEATING & HOT WATER | ||||||
Model | RF8I/bdm | RF12I/bdm | RF13I/bdm | HF20I/bdm | ||
Rated Heating | Heating capacity | kW | 9.00 | 15.00 | 18.00 | 20.00 |
Power input | kW | 2.59 | 4.31 | 5.14 | 5.81 | |
COP | W/W | 3.47 | 3.48 | 3.50 | 3.44 | |
Nominal Heating | Heating capacity | kW | 5.53 | 10.50 | 12.10 | 14.50 |
Power input | kW | 2.34 | 4.43 | 5.13 | 6.01 | |
COP | W/W | 2.36 | 2.37 | 2.36 | 2.41 | |
IPLV(H) | W/W | 2.80 | 2.85 | 2.85 | 2.86 | |
Low Temp. Heating | Heating capacity | kW | 4.50 | 8.90 | 10.10 | 12.50 |
Power input | kW | 2.34 | 4.56 | 5.10 | 5.95 | |
COP | W/W | 1.92 | 1.95 | 1.98 | 2.10 | |
Rated Cooling | Cooling capacity | kW | 8.00 | 11.50 | 12.00 | / |
Power input | kW | 3.20 | 4.60 | 4.80 | / | |
EER | W/W | 2.50 | 2.50 | 2.50 | / | |
Power Supply | V/Ph/Hz | 220/1/50 | ||||
Max. Power Input (With E-Heater) | kW | 4.4(+3) | 5.2(+3) | 6.6(+3) | 7.1(+3) | |
Max. Current Input (With E-Heater) | A | 20(+13.6) | 23.7(+13.6) | 30(+13.6) | 32.5(+13.6A) | |
Max. Water Temp. (Without E-Heater) | ºC | 58 | ||||
Working Range (Ambient temp.) | ºC | -30 to 43 | -35 to 43 | |||
Refrigeration Circulation | Refrigerant | Type | R410A | |||
Qty./Kg | 1.7 | 3.15 | 3.15 | 3.15 | ||
Compressor | Qty. | 1 | ||||
Type | DC INVERTER DOUBLE ROTOR | EVI DC INVERTER DOUBLE ROTOR | ||||
Brand | GMCC | |||||
Evaporator | Type | High efficiency hydrophilic aluminum foil fin heat exchanger | ||||
EEV | Brand | SANHUA | ||||
Fan Motor | Qty. | 1 | 2 | |||
Power Input(W) | 140 | 2*150 | ||||
Fan Blades Size | mm | Φ560*139 | Φ525*135 | |||
Liquid valve size | inch(mm) | 3/8"(9.52) | ||||
Gas valve size | inch(mm) | 5/8"(15.88) | ||||
Water system | Condenser | Type | Tube in tube heat exchanger | |||
Water Pump | Brand | XINHU | ||||
Model | GPD25-12S | |||||
Water Flow | m3/h | 1.38 | 1.98 | 2.06 | 2.5 | |
Water Drop | kpa | 35 | 35 | 38 | 48 | |
Air Vent Valve | / | Standard | ||||
Pressure Release Valve | / | Standard | ||||
Pressure value | 3kgs | |||||
E-Heater | kW | 3 | ||||
Buffer Tank | L | 5 | ||||
Water Inlet/Outlet Pipe | inch(mm) | 5/4" male | ||||
Net Dimensions | indoor Unit (L*W*H) | mm | 760x510x330 | |||
Outdoor Unit (L*W*H) | mm | 947x403x813 | 940x393x1373 | |||
Package Size | indoor Unit (L*W*H) | mm | 795x562x373 | |||
Outdoor Unit (L*W*H) | mm | 1050x468x847 | 1060x490x1395 | |||
N.W. | Indoor Unit | kg | 43 | |||
Outdoor Unit | kg | 63 | 110 | 115 | ||
G.W. | Indoor Unit | kg | 48 | |||
Outdoor Unit | kg | 70 | 125 | 130 | ||
Noise Level | Indoor Unit | dB(A) | ≤35 | |||
Outdoor Unit | dB(A) | ≤59.5 | ≤61.5 | ≤62 | ||
Product implementation standards: GB/T 25127.2-2010 GB/T 18430.2-2016 Testing Condition: - Rated heating: Inlet/outlet temperature 40°C/45°C. Dry bulb/wet bulb temperature 7°C/6°C - Nominal heating: Outlet temperature 41°C. Dry bulb/wet bulb temperature -12°C/-14°C - Low temperature heating: Outlet temperature 41°C. Dry bulb/wet bulb temperature -20°C/-21°C - Rated cooling: Inlet/outlet temperature 12°C/7°C. Dry bulb/wet bulb temperature 35°C/24°C - Internal and external machine connection copper pipe are 5m. If need for exceeds 7.5m, you need to contact the manufacturer to change the amount of refrigerant. |
DC INVERTER AIR TO WATER HEAT PUMP, DC INVERTER AIR SOURCE HEAT PUMP, SPLIT HEAT PUMP, MONOBLOCK HEAT PUMP, AIR TO WATER HEAT PUMP FOR COOLING AND HEATING, AIR SOURCE HEAT PUMP FOR COOLING AND HEATING, AIR WATER HEAT PUMP.