HDGC3970-CDY15010/CDY15020
1 Year
1 Year
Storage Battery Tester
Charge and Discharge
Lead-acid Battery
Customized
7 Inch Color LCD Display
220V 45-65Hz
-5-50ºC
45kg
630*390*740mm
Compliance with En610950
Air Cooling
HD Power
Cell Battery Monitor
HD Power
Wooden Box with Foam Inside
Made in China
9030899090
Product Description
HDGC3970 Series Battery Charging Tester | ||
Type: HDGC3970- | CDY15010 | CDY15020 |
Output | ||
Charging Voltage Range | 60-200V | |
Charging Current Range | 0~100A | 0~200A |
Output power | ≤20KW | ≤40KW |
Group voltage resolution | 0.1V | |
Group voltage accuracy | ±0.5%FS+0.1V(Full scale) | |
Current measurement accuracy | ±1%FS+0.1A(Full scale) | |
Battery capacity check range | 0-1000Ah | 0-200Ah |
Display | ||
Display Material | Resistive Touchscreen | |
Display Mode | 7-Inch LCD true color, resolution: 1024*800 | |
Working Mode&Data | ||
Working mode | Single main unit / parallel master mode / parallel slave mode / remote controlled mode / Quick Test | |
Data storage capacity | Internal: 16Gbit TF card | |
Data communication | RS485*3,USB*1,RF433 | |
Protection Performance | ||
Battery side protection | Under-voltage, over-voltage, over-current, over-temperature, short-circuit, reverse connection protection | |
Audible and visual alarm | Reverse polarity, cut-off condition completion triggers LCD prompt, beep warning | |
Emergency stop protection | External open circuit breaker for emergency shutdown protection | |
Power Supply | ||
Voltage | Single-phase3-Wire AC220V (-20%-+30%), frequency: 45-65Hz; | |
Withstand voltage | Input-shell: 2200Vdc 1min / Input-output: 2200Vdc 1min / Output-shell: 700Vdc 1min | |
With Cell Monitoring Model(Optional) | ||
Cell Voltage Measurement Range | 1.00V~16.00V,Resolution: 0.01V (the resolution can be accurate to 0.001V through the software view) | |
Cell Voltage Measurement Accuracy | ±0.1%FS |
Product Profile
HDGC3970 Battery Charge Tester is mainly used for the charge test of the lead-acid battery of the backup power supply in the telecommunications, mobile, substation, railway transportation and pertrochemical industry power DC industries. It keeps the constant communication maintain between the battery charge ensuring a perfect charge.
Battery charge tester is designed using intelligent three-stage charging mode to achieve the function of automatic conservation between charging and floating charge. It also can on-line detect the voltage of the whole battery, real-time display and record the voltage of whole battery. The tester can automatically accomplish charging after setting the parameter of voltage, current, time and capacity.
HDGC3970 Battery Charge Tester is mainly used for the charge test of the lead-acid battery of the backup power supply in the telecommunications, mobile, substation, railway transportation and pertrochemical industry power DC industries. It keeps the constant communication maintain between the battery charge ensuring a perfect charge.
Battery charge tester is designed using intelligent three-stage charging mode to achieve the function of automatic conservation between charging and floating charge. It also can on-line detect the voltage of the whole battery, real-time display and record the voltage of whole battery. The tester can automatically accomplish charging after setting the parameter of voltage, current, time and capacity.

Rapid replenishment function: It can quickly replenish the battery pack by short time, effectively activate the internal chemical composition of the battery, and at the same time, after replenishment, it can effectively solve the problem of differential pressure sparks of the charging module closing.
Multiple operating modes: constant current charging, constant voltage current limiting charging, trickle float charging, etc.
7inch 1024*600 LCD screen: Intelligent SCM ARM control, , capacitive touch operation, built in English menu, simple and clear operation menu.
Multiple safety protection functions: over-current protection, short-circuit protection, high temperature, reverse polarity and other protection functions.
With a number of alarm functions: the use of the process of abnormal problems, such as high voltage, under-voltage, current outside the measurement range, fan failure, etc. can be issued in real time to warn and stop discharging, do not damage the instrument and related testing equipment.
Intelligent operation design: Equipped with quick docking jack, simple connection, automatic recording and intelligent analysis of the whole test, without human intervention.
Charging parameter preset function: Built-in a variety of commonly used charging templates to meet the parameters of different types of batteries, template data can be saved when the power is off, the power can be directly started to test, no need to set up frequent parameters
Cell voltage wireless monitoring function: Compatible with 2V/6V/12V cell voltage monitoring,each wireless monitoring module can simultaneously monitor 12 cells.