Product Description
Fully isolated single-phase AC voltage regulator module DTY-H220D75E DTY-H220D75F DTY-H220D75G DTY-H220D75H
The last digit of the model is the input control signal type, E means 0-5V; F means 0-10V; G means 4-20mA; H means 1-5V.
Fully isolated single-phase AC voltage regulation module (hereinafter referred to as single-phase voltage regulation module DTY) is a synchronous transformer, phase detection circuit, phase shift trigger circuit and output thyristor in one, when the size of the control voltage is changed, the output can be changed The triggering phase angle of the SCR can realize the voltage regulation of single-phase alternating current. According to the different output thyristor devices, it is divided into three types: a common type of bidirectional thyristor, an enhanced type with two unidirectional thyristors in anti-parallel, and a half-wave type with one unidirectional thyristor. According to the rated voltage of single-phase AC load, it is divided into two categories: 220V and 380V, and four categories according to the different control signals: E, F, G, H, etc. The following is a table of specifications and models: (Note: The current rating is SCR inside the module Maximum current effective value)
2 Model list
Types of | Electric current | Choose one of 220V load last E\F\G\H | Choose one of the last E\F\G\H of 380V load |
Enhanced | 15A | DTY-H220D15E | DTY-H380D15E |
35A | DTY-H220D35E | DTY-H380D35E | |
55A | DTY-H220D55E | DTY-H380D55E | |
75A | DTY-H220D75E | DTY-H380D75E | |
120A | DTY-H220D120E | DTY-H380D120E | |
150A | DTY-H220D150E | DTY-H380D150E | |
190A | DTY-H220D190E | DTY-H380D190E | |
240A | DTY-H220D240E | DTY-H380D240E | |
290A | DTY-H220D290E | DTY-H380D290E | |
350A | DTY-H220D350E | DTY-H380D350E | |
normal type | 10A | DTY-220D10E | DTY-380D10E |
25A | DTY-220D25E | DTY-380D25E | |
40A | DTY-220D40E | DTY-380D40E | |
Half-wave | 10A | DTY-220D10XE | DTY-380D10XE |
25A | DTY-220D25XE | DTY-380D25XE | |
50A | DTY-220D50XE | DTY-380D50XE |
E series | F series | G series | H series | |
Input range | 0~5V | 0~10V | 4~20mA | 1~5V |
input resistance | >30KΩ | >30KΩ | 250Ω | >30KΩ |
Effective input range | 0.75~4.75V | 1.5~9.5V | 5~19mA | 1.25~4.75V |
Phase shift angle range | 150°~0° | 150°~0° | 150°~0° | 150°~0° |
1.2.is the output terminal, that is, the corresponding random solid-state relay output terminal, the voltage level is 380VAC specification, and can be used on the power grid less than 420Vac. According to the difference of thyristor inside the module, it is also divided into ordinary type, enhanced type and half-wave type like solid state relay. The half-wave type is a unidirectional thyristor used as the output contact, and only regulates the positive half cycle of the AC voltage (the anode of the unidirectional thyristor inside the module is connected to the 1. end, and the cathode is connected to the 2.end).
3.4.It is the primary part of the internal synchronous transformer of the module, which is divided into two specifications of 220VAC and 380VAC: the module of 220VAC specification is allowed to be used on the power grid in the range of 165-240VAC, and the module of 380VAC specification is allowed to be used on the power grid of 285-420VAC, 3.4. regardless of the end of the same name .
COM is the internal ground terminal, CON is the control terminal, and the +5V terminal is internally generated. It is only used for manual control of the power supply. The strong current part of 1.2.3.4. is fully isolated from the weak current part of +5V, CON and COM.
Half-wave | Used for electric shock airport closure |
normal type | Small current module or dv/dt with lower requirements |
Enhanced | High current module or dv/dt demanding occasions |
220V | 220V loop load |
380V | 380V loop load (that is, add two live wires to the load) |
Current capacity selection | 1. For resistive loads, the current level of SSR should be greater than or equal to twice the rated current of the load. |
2.When the load is an AC motor, the current level of SSR must be greater than or equal to 6-7 times the rated current of the motor. | |
3. For AC electromagnet, intermediate relay wire protection, inductance coil and other loads, the current level of SSR should be greater than or equal to 4 times the rated load current. | |
4.When compensating for capacitor-type loads, the current level of SSR must be greater than 5 times the rated current of the load. | |
5. The transformer requires 5 times or more of the transformer primary rated current, and the special inductive and capacitive loads should also amplify the SSR current margin according to actual experience. |