Dam3-400 MCCB Compact Economical Type Moulded Case Circuit Breaker Factory Price CB Approved for Switchgear Application

Price $40.00 Compare
Min Order 1000 Pieces
Shipping From Shanghai, China
Popularity 211 people viewed
Quantity
+-
 

Shanghai DaDa Electric Co., Ltd.

VIP   Audited Supplier 5 years
Profile Certified by SGS/BV
DAM3-400
Low Voltage Circuit Breakers
Manual Type
Normal Type Circuit Breaker
Arc Chamber
Fixed
MCCB
3
Circuit Breaker
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection
ISO9001-2000, CE, CB, CCC, RoHS
BMC Unflaming Material
1000V
400/415V
CDADA, OEM, ODM
Carton
250, 315, 400A
Shanghai, China
8536200000
Product Description

Overview



The rated current of the Dada DAM3-400 molded case circuit breaker can reach up to 400A. These electrical devices are suitable for the protection of power distribution circuits with an alternating current of 50-60Hz and a rated operating current to 1600A. They can also be used in electric motors for infrequent starting and overload protection as well as protection against short circuiting and undervoltage conditions.

Compared to the DAM1 series, the DAM3 series are designed for smaller volume, higher breaking capacity, offering better energy savings.

Electrical parameters of DAM3-400 molded case circuit breaker
Rated current of frame size Inm [A] 400
Rated current [A]200-400
Number of poles3 / 4
Rated operating voltage(AC)50-60HZ [V]400/690
DC [V]250/1000
Rated impulse withstand voltage Uimp [KV]8
Rated insulation voltage Ui [V]750
Test voltage at industrial frequency for 1 min [V]3000
Rated ultimate short-circuit breaking capacity Icu [KA]CNSH
(AC)50-60HZ 220/230V[KA]455580105
(AC)50-60HZ 400/415V [KA]30365570
(AC)50-60HZ 690V [KA]12152025
(DC)250V-2 Poles in series30355065
(DC)500V-2 Poles in series12182230
(DC)750V-4 Poles in series18304255
(DC)1000V-4 Poles in series15253545
Rated service short-circuit breaking capacity, Ics [KA]    
(AC)50-60HZ 220/230V [%Icu]60%60%60%60%
(AC)50-60HZ 400/415V[%Icu]60%60%60%60%
(AC)50-60HZ 690V [%Icu]60%60%60%60%
category of utilisation(EN 60947-2)A
Isolation conditionBitmap
Reference standardIEC/EN 60947-2/GB 14048.2
InterchangeabilityBitmap
VersionsFixedBitmap
Plug-inBitmap
Draw-outBitmap

Physical parameters of DAM3-400 molded case circuit breaker
EnduranceTotal cycles8000
Electrical endurance1000
Mechanical endurance7000



Basic dimensions-fixed version
3/4 Poies W[mm]120/159140/210
3/4 Poies H[mm]100100
H1[mm]133.5135
3/4 Poies L[mm]180215

Introduction
The DAM3-400 molded case circuit breaker automatically cuts off the current when the current exceeds the release setting. The molded case refers to the plastic insulator used as the frame of the device to insulate the conductor and the metal grounding component.