YP BLX-8plus
Oral Surgery
CE
X-Ray Equipment
Plastic
60kv
1-9s
1mA
2kg
24V DC 8000mA
0.3mm(Toshiba)
AC110V~220V
60W
YP Dental
Carton
1pc/boxes
China
Product Description
Product introduction:
This model combines the advantages of similar products found at home and abroad; it eliminates the shortcomings of the on-frequency X-ray machine (high current intensity and excess amounts of scrap x-rays).Using a Toshiba 0.3 micro-focus tube.The tube voltage frequency of this machine is 30 KHz,and the tube current is 1 MA. The radiation scope is at an angle of 24 degrees,located within a distance of 1.2 meters ahead. This is an innovative Chinese design named the "Green X-ray Machine."
Technical specifications
Reference of the Angles : | ||
Tooth | Upper | Lower |
1-2 | 42 | -15 |
3 | 45 | -18 |
4-5 | 30 | -10 |
6-8 | 28 | -5 |
Reference of the time of exposure: | ||
Tooth | Adult | Child |
Central & Lateral | 0.2-0.3s | 0.2-0.3s |
Cuspid & 1st Bicuspid | 0.3-0.4s | 0.3-0.4s |
Upper 5,6 | 0.5-0.6s | 0.5-0.6s |
Upper 7,8 | 1.3-1.8 s | 1.2-1.5.s |
Lower 5,6 | 0.5-0.6s | 0.4-0.5 s |
Lower 7,8 | 0.6-0.8 s | 0.5-0.7 s |
Packing List
Main machine :1pcs
Power line :1pcs
User manual :1pcs
Power line :1pcs
User manual :1pcs
Operation of the Main Unit
Upon receiving,open the box and check the product for possible damage during shipping.
Make sure the fittings on the encasement list are packaged within the box.
Install the blue ray tube to the foreside of the ball head,then tighten it.
Turn on the Power;the pilot lamp will be light up.During this time,the digital tube will show the fore setting time. Now the equipment is in standby mode. Setting the time (Skip to next step if unneeded) Use the "SET","+",and" -" buttons to reset the time as follows: press SET,the pilot lamp above is illuminated, the machine is now in the time setting mode → then press "+" and" -" to set the time needed (time range is 1-9seconds); press set again when the time is adjusted the light lamp is off. The equipment is now in standby mode. Put the Tooth film plumb behind the tooth which is going to be taken picture, and be as close as possible (the smooth side stick to the tooth) Keep the ball head plumb to the tooth projection position; Have the ball head,tooth, and tooth film steadily mutually plumb.
After positioning,use the ON/OFF on the main Unit, to take pictures. (Notice: gently press 0.5 sec to turn it on)
After exposure to the tube,press the start button again in case of an emergency to stop shooting and return to standby status. (At this point there was no output ray,so the dental films can be used again).
Repeat step 6 to reset the picturing time.To repeat the picturing process,please repeat steps 7 to 9.
Turn the power off when the work is finished,press POWER, making sure the pilot lamp is off.Don't keep the machine long in standby mode.
Make sure the fittings on the encasement list are packaged within the box.
Install the blue ray tube to the foreside of the ball head,then tighten it.
Turn on the Power;the pilot lamp will be light up.During this time,the digital tube will show the fore setting time. Now the equipment is in standby mode. Setting the time (Skip to next step if unneeded) Use the "SET","+",and" -" buttons to reset the time as follows: press SET,the pilot lamp above is illuminated, the machine is now in the time setting mode → then press "+" and" -" to set the time needed (time range is 1-9seconds); press set again when the time is adjusted the light lamp is off. The equipment is now in standby mode. Put the Tooth film plumb behind the tooth which is going to be taken picture, and be as close as possible (the smooth side stick to the tooth) Keep the ball head plumb to the tooth projection position; Have the ball head,tooth, and tooth film steadily mutually plumb.
After positioning,use the ON/OFF on the main Unit, to take pictures. (Notice: gently press 0.5 sec to turn it on)
After exposure to the tube,press the start button again in case of an emergency to stop shooting and return to standby status. (At this point there was no output ray,so the dental films can be used again).
Repeat step 6 to reset the picturing time.To repeat the picturing process,please repeat steps 7 to 9.
Turn the power off when the work is finished,press POWER, making sure the pilot lamp is off.Don't keep the machine long in standby mode.
Make sure the angle of film,tooth,and ball head are properly aligned when taking a picture.
Keep them steady until the last step of picturing; making sure that there is no change in any of their positions.
Remember to turn the power 0ff when work is done.Charge the battery if the machine cannot work and the red lamp light
After turning the power on,wait one minute before taking pictures,this allows the ray to provide a steady output.
The equipment switches into protection mode automatically when the voltage is incorrect. If this occurs, it will not be able to carry out the normal work of filming.
When taking pictures,the ON/OFF button could stop the objection and then the machine goes back to the preparation mode. Use high quality tooth film and developing liquid to make clear pictures.
Handle the ball head gently while in use,so as not to damage the delicate component.
We usually set the time between 3-8 seconds when taking pictures,but the actual time of ray output is 0.2-0.5 seconds.
If a situation occurs, preventing the machine from taking regular pictures, contact the seller to solve the problem instead of trying to service the product yourself.
Keep the tooth film and the liquid in a proper place and use them within the shelf-life period.
Development of films should be performed at temperatures ranging between 23-25 degrees
Celsius to ensure the image quality.
Other requests accordance with the scope of the technical parameters.
Please read the manual carefully before using.
Keep them steady until the last step of picturing; making sure that there is no change in any of their positions.
Remember to turn the power 0ff when work is done.Charge the battery if the machine cannot work and the red lamp light
After turning the power on,wait one minute before taking pictures,this allows the ray to provide a steady output.
The equipment switches into protection mode automatically when the voltage is incorrect. If this occurs, it will not be able to carry out the normal work of filming.
When taking pictures,the ON/OFF button could stop the objection and then the machine goes back to the preparation mode. Use high quality tooth film and developing liquid to make clear pictures.
Handle the ball head gently while in use,so as not to damage the delicate component.
We usually set the time between 3-8 seconds when taking pictures,but the actual time of ray output is 0.2-0.5 seconds.
If a situation occurs, preventing the machine from taking regular pictures, contact the seller to solve the problem instead of trying to service the product yourself.
Keep the tooth film and the liquid in a proper place and use them within the shelf-life period.
Development of films should be performed at temperatures ranging between 23-25 degrees
Celsius to ensure the image quality.
Other requests accordance with the scope of the technical parameters.
Please read the manual carefully before using.







Certifications
Packaging & Shipping
Company Profile
Anyang Yingpai Dental Material Co.,ltd. ever been named Linzhou Chengjiao Dental Material Co.,ltd, which set up in 1998. It is located in Shangguan Town, Hua County, Anyang city, Henan province, China. In accordance with the thousand of rusic folkway of central plains.
Honest, specialization and high-grade ae our operation object. We specialize in the production and development of the synthetic resin teeth with the precise and keep-high quality, good reputation, best service. We have make a long time business relations with the customers from the Europe market, Asia market, USA market, Africa market and latin America market.
The manufacturing and R&D of the production. Through choosing the international advanced production principle and technology, we can make each kind synthetic resin teeth. W have 28kinds regular anterior teeth and posterior teeth, of course, we can make the special teeth for you as your order.
Through choosing the international advanced CAD/CAM and vacuum-filling manufacturing process, we make our product to reachthe internation advanced level on the shape, wear-resistance and the shade. Our products are famous for the vivid shape, compact tissue, perfect articulation, strong chew and the clear pronunciation.
FAQ
1. who are we?
We are based in Henan, China, start from 2011,sell to Domestic Market(60.00%),Southeast Asia(5.00%),Mid East(5.00%),Africa(5.00%),Eastern Europe(3.00%),South Asia(3.00%),Eastern Asia(3.00%),South America(3.00%),Central America(3.00%),Western Europe(2.00%),North America(2.00%),Southern Europe(2.00%),Northern Europe(2.00%),Oceania(2.00%). There are total about 101-200 people in our office.
2. how can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;
3.what can you buy from us?
Resin Teeth,Dental Material,Dental Consumables
4. why should you buy from us not from other suppliers?
Through choosing the international advanced production principle and technology, we can make each kind synthetic resin teeth. W have 28kinds regular anterior teeth and posterior teeth, of course, we can make the special teeth for you as your order.
5. what services can we provide?
Accepted Delivery Terms: FOB,CIF,EXW;
Accepted Payment Currency:USD;
Accepted Payment Type: T/T,Western Union;
Language Spoken:English,Chinese