Dialysis Machine Kidney Hemodialysis Medical Kidney Dialysis Machine for Home

Price Negotiable Compare
Min Order 1 Piece
Shipping From Guangdong, China
Popularity 454 people viewed
Quantity
+-
 

Guangzhou Med Equipment Limited

VIP   Audited Supplier 10 years
Profile Certified by SGS/BV
MED-L-2028
Customized
ISO13485
Blue
Human Blood Processor
Volume 370mm*340mm *1570mm
Weight About 90kg
AC220V/110V 50Hz / 60 Hz ,Power: 1500W
0MPa~0.6MPa
5~30degree
Hot Rinse 80 Degree
Med Equipment
Standard Packing for Export
Standard
Guangzhou China
Product Description
Dialysis Machine 
Model: MC-JHM-2028  Double Pumps
 
Dialysis Machine 
Model: MC-JHM-2028  Double Pumps
 
1. Volume (length× width ×height): 
370mm×340mm ×1570mm
2.  Weight: about 90kg 
3. Power supply voltage: 
AC220V/110V  50HZ / 60 HZ ,Power: 1500W
 
4.  Blood pump/spare pump:
   ?Flux: 15 ~ 340ml/min (D 6mm)
          20 ~ 460 ml/min (D 8mm)
5. Heparin pump:
   ?Flux: 0ml/h~10ml/h(±5%)  
   ?Precise: 0.1ml/h
   Injector size: 20ml/30ml/50ml
               10ml/20ml/30ml (selectable)
6.  Arterial pressure:
  ?display scope:-300mmHg~+300mmHg
                          (±10mmHg)
7.  Venous pressure:
  ?display scope:-50mmHg~+300mmHg
                          (±10mmHg)
 
8.  Dialysate flow:
  300ml/min~800ml/min linearity adjustable  (+10%) (-5%)
  Temperature:35.0ºC~39.0ºC
  Resolving rate:0.1ºC
  Conductivity:13mS/cm~15.5mS/cm   (±0.1 mS/cm)
 
9. UF flow scope: 0~1800ml/h(±30ml/h )
                0~4000ml/h(optional)
10. ISO UF flow scope:0~2000ml/h(±30ml/h)
11. TMP:  Scope:-100mmHg~+600mmHg   (±20mmHg)
12.  Blood leakage monitor:
   over 1ml blood per liter dialysate  (flow:500ml/min)
13. Blood level monitor: ultrasonic sensor
14.  Air bubble monitor:
   Infrared and response threshold value:
   Single air bubble of 200  I exists when
    Blood flux is 200ml/min
15.  Inflow pressure:0MPa~0.6MPa
16.  Inflow temperature: 5ºC~30ºC
17.  Environment temperature: 10ºC~30ºC,
    Relative humidity≤70%
18. Rinse/disinfection: chemical disinfection
   (citric acid,peracetic acid and oxalic acid)
 
19. Hot rinse: 80ºC
20. Back-up power supply: last for 15-30min after electric-cut.
 
   
   
MC-JHM-2028 function
  Be applicable of hemodialysis treatment,hemoperfusion,Plasma Exchange,Pure ultrafiltration project.Touch screen was equipped and it can show Naand UF profiles;In addition,the functions ie.backup power supply, Kt/V,HCO3adjustment,single needle,acetate treatment,pyrogen filter port and net connection ect.are optional.
 
Clinical Application
 
--- Hemodialysis Therapy:same as JH-2000
--- Pure ultrafiltration Therapy: same as JH-2000
--- Hemoperfusion Therapy:same as JH-2000
--- Plasma exchange Therapy:same as JH-2000
--- Na+and UF profiling:
 Be applicable for reducing the cases during dialysis treatment such as low/high pressure,muscle convulsion, 
 headache,nausea,vomit ect.
--- Kt/V function:
  ·The sufficiency of dialysis can be reflected by Kt/V.
---HCO3  adjustment function:
  Be applicable for sericous acid toxicosis patient.
  Be capable to calibrate the acid toxicosis status according to patient's state of illness.
--- Backup power-supply:
  ·It can last for 15-30 minutes after power cut off.
--- Pyrogen filter port:
  Completely filtrating the remained bacteria and endotoxin.(optional)
--- Net connection:
  One computer can audit and control the treatment of maximum 20 units hemodialysis machine (optional)
 
 
 Medical Euiqpment

Hospital Furniture and Surgical Equipment

X-Ray Machine and Ultrasound Scanner

Obstetric Gynaecology Centre and Rehabilitation Therapeutic Apparatus

Dental Clinic Equipment and Ophthalmoscope

Laboratory Equipment

Sterilizer & Disinfection Products

Mortuary Equipment

Homecare Product

Veterinary Equipment and Education Equipment

Why Choose MeCan










Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA