SF-1046
IVD Reagent
Biological Diagnostics
CE, ISO13485
Female
99.9%
10 Miu/Ml
Urine
Midstream
Digital Pregnancy Test Kit with Indicator
CE ISO
SD
Carton
Tianjin
3822190090
Product Description
Diagnosis Digital Pregnancy Test with Week Indicator
The Digital Pregnancy Test with Weeks Indicator is as accurate as an ultrasound scan at dating pregnancy. Its Smart Dual Sensor not only tells you in words if you're 'Pregnant' or 'Not Pregnant', it also tells you how far along you are.
When to use Digital Pregnancy Test?
Features:
Unique-The ONLY REUSABLE digital pregnancy test which can tell her how many weeks (1-2 weeks, 2-3 weeks, 3 + weeks);
Accurate-Over 99% accurate;
Unmistakably Clear-Results displayed on a digital screen;
Sensitive-Can be used 4 days before the expected period;
Convenient-Easy to use, Easy to read;
Reusable-Monitor is reusable



Shipping:
By ship, plane or express according to quantity
One Step Fertility & Eugenic Test Products Profile
The Digital Pregnancy Test with Weeks Indicator is as accurate as an ultrasound scan at dating pregnancy. Its Smart Dual Sensor not only tells you in words if you're 'Pregnant' or 'Not Pregnant', it also tells you how far along you are.
When to use Digital Pregnancy Test?
Based on cycles of 28 days | End of 28 days cycle | Beginning of 28 days cycle | |||
Day of Cycle | 26 | 27 | 28 | 1 | 2 |
When to start Digital Pregnancy Test | 4 days before the missed period | 3 days before the missed period | 3 days before the missed period | 1 days before the missed period | The day of the missed period |
Features:
Unique-The ONLY REUSABLE digital pregnancy test which can tell her how many weeks (1-2 weeks, 2-3 weeks, 3 + weeks);
Accurate-Over 99% accurate;
Unmistakably Clear-Results displayed on a digital screen;
Sensitive-Can be used 4 days before the expected period;
Convenient-Easy to use, Easy to read;
Reusable-Monitor is reusable
Product name | Digital Pregnancy Test with week indicator ( HCG) |
Specimen | Urine |
Format | Midstream |
Accuracy | Over 99% |
Warranty | 2 year |
Package | Individual Foil Pouch |
Usage | Pregnancy Testing |
Application | Fertility center;home rapid test;fertility hospital |
Function | Can test pregnant weeks |
Compose | one monitor+1-3 test stickers |
Sensitivity | 10 Miu/Ml |
How to use:
To ensure that you use the Monitor correctly,read the instructions carefully.
1. Immerse the strip into the urine with the arrow end pointing towards the urine. Do not immerse past the Marker Line .
2. Take the strip out after 10 seconds and lay the strip flat on a clean, dry, non-absorbent surface.Wait for colored bands toappear. Depending on the concentration of HCG in the test specimen, Positive results may be observed in as short as 40 seconds.Positive: If two color bands are visible and the test band is equal in color intensity or darker as compared to the control band. It is considered positive and you will probably ovulate within the next 24-48 hours. Negative: Only one color band appears on the control region or the test band is lighter in color intensity as compared to the control band. There is no LH surge. Invalid: No visible bands at all or only one red reactive band appears on the test region. It is indicated the test failed or the strip is invalid, which is recommended in this case that the test should be repeated.
However, to confirm Negative results, the complete reaction time (10 minutes) is required. So read the result within 5 minutes.



To ensure that you use the Monitor correctly,read the instructions carefully.
1. Immerse the strip into the urine with the arrow end pointing towards the urine. Do not immerse past the Marker Line .
2. Take the strip out after 10 seconds and lay the strip flat on a clean, dry, non-absorbent surface.Wait for colored bands toappear. Depending on the concentration of HCG in the test specimen, Positive results may be observed in as short as 40 seconds.Positive: If two color bands are visible and the test band is equal in color intensity or darker as compared to the control band. It is considered positive and you will probably ovulate within the next 24-48 hours. Negative: Only one color band appears on the control region or the test band is lighter in color intensity as compared to the control band. There is no LH surge. Invalid: No visible bands at all or only one red reactive band appears on the test region. It is indicated the test failed or the strip is invalid, which is recommended in this case that the test should be repeated.
However, to confirm Negative results, the complete reaction time (10 minutes) is required. So read the result within 5 minutes.






Shipping:
By ship, plane or express according to quantity

One Step Fertility & Eugenic Test Products Profile
Product | Specimen | Type | Sensitivity |
Pregnancy HCG Test Kit | Urine/Serum | strip/cassette/midstream | 25mIU/ml |
Digital Pregnancy Test Kit | Urine | midstream | 25mIU/ml |
Ovulation (LH) Test Kit | Urine | strip/cassette/midstream | 25mIU/ml |
FSH(Follicle-stimulating Hormone) | Urine | strip/cassette/midstream | 25mIU/ml |
fFN(Fetal Fibronectin) | cervical mucus | strip/cassette | 25ng/ml |
Sperm-density | Semen | cassette | N/A |
HSV I lgG/lgM | whole blood/ serum/plasma | cassette | N/A |
HSV II lgG/lgM | whole blood/ serum/plasma | cassette | N/A |
HSV 1+2 lgG/lgM | whole blood/ serum/plasma | cassette | N/A |
TOXO IgG/IgM | whole blood/ serum/plasma | cassette | N/A |
RV IgG/IgM | whole blood/ serum/plasma | cassette | N/A |
CMV IgG/IgM | whole blood/ serum/plasma | cassette | N/A |
TORCH IgM combo-5 | whole blood/ serum/plasma | cassette | N/A |
TORCH IgG/IgM combo-5 | whole blood/ serum/plasma | cassette | N/A |