Disconnect Switch with Drive Mechanism

Price $3000.00 Compare
Min Order 1 Piece
Shipping From Zhejiang, China
Popularity 479 people viewed
Quantity
+-
 

Hangzhou Yongde Electric Appliances Co., Ltd.

VIP   Audited Supplier 15 years
Profile Certified by SGS/BV
gw38
High-voltage
Three-column Disconnector
Outdoor High-voltage
Manual
Grounding
Vertical Rotary Type
Three Pole
Double Ground
Three
Vertical Rotation
Single Throw-in
Gw
Manual
ISO, ISO9001
Yongde
200~600A
YONGDE
Wooden Case
SGS
China
8535300000
Product Description
Disconnect Switch With Drive Mechanism

GW38-40.5~252/630~4000 Type Three post Horizontal Double break disconnector
Double break is good for reducing the distance and station arranging, especially for indoor station
Because of electric rod's self-rotation and switching structure and having self-locking function, it has strong property of motor performance resistance. Meanwhile, it can resist motor, wind pressure, earthquake and other outside power
Contact and finger's on and off way is sliding rotation, having strong self-clean ability.
In the galvanic circle, the section is the combination structure made by screw fix linking, having the good property of stable flowing, high reliability, simple change way and convenient adding volume way.
In the galvanic circle, the contact and finger is made by T2Y pure copper tap whose connecting part is coated by 30μ M silver.
Finger spring is made by the stainless steel and its design is the inside hiding and outside press structure which is convenient for testing and changing
The bearing has changed from the bevel rear structure to the Universal connecting rod drive structure, having the advantage of simple structure, high intensity, convenient operation way and safety enough.
Bearing block is made by high-intensity casting steel (disposed by hot zinc coating), the height can be adjusted and have the function of damping.
Have different install way such as front install, side install, back install and leak 25° Install and so on, adapting to different station entering line ways.
All the operating rod and linking rod are supplied by manufacturer, which is convenient for loading, adjusting and testing.
It can be supplied as a whole above the ground according to user's requirement.
NoItemTechnical parameter
1Rated Voltage                                  kV72.5123145245
2Rated Current                                  A1250  1600  2000  2500  3150  4000
3Rated Short Time withstand current and Time                                kA/s25~50/4
4Rated Peak withstand current  kA63~125
51min power frequency  withstand voltage (effective value)    kVTo earth140230275460
To phase140230275460
Across Isolating DS180300315605
6Lightning Impulse wishstand voltage
(peak value)        kV
To earth3255506501050
To phase3255506501050
Across Isolating DS4056507501200
7Rated mechanical terminal load            NLevel of lateral load750150015002000
Level of vertical load500100010001500
Vertical750100010001250
8Capacity and Inductive Ability (open and close)Capacity Current  A1
Inductive Current  A0.5
9Max Man Operative Moment    N. m200
10Motor Drive operating mechanism control voltage                            VAC220; DC110, 220
11Motor Drive operating mechanism motor  voltage                                  VAC220, 380; DC110, 220