Disposable DPT Transducer Kit with Utah Connector

Price $6.00 Compare
Min Order 2 Pieces
Shipping From Guangdong, China
Popularity 496 people viewed
Quantity
+-
 

Shenzhen JCR Medical Technology Limited Company

VIP   Audited Supplier 4 years
Profile Certified by SGS/BV
JIBPT-01-UT
Surgical Supplies Materials
High Polymer Material and Electronic Chips
Ethylene Oxide Sterilization
Three Years
All
With Logo Printing
Disposable Pressure Transducer
Medical Materials & Accessories
CE/ISO13485/TUV
40/96PCS in a Box
30ml/Hr
Single/Double/Triple Are Options
Mr/Abbot/Bd/Argon/USB/PVB/Utah/Bruan/Edwards
OEM/ODM
JCR
Sterile Blister Box
224*113*45mm
China
9018909991
Product Description
Disposable pressure transducer kit 
 
Disposable Pressure Transducer is used in ICU Anesthesiology and enable to consist and accurate reading of arterial and venous blood pressure measurement.

- Infusion set 
- Pressure monitoring line 
- Stopcock etc 
- Infusion set 
- Pressure monitoring line
- Stopcock etc
- Medical disposable
 

Product Description

Properties
Medical Materials & Accessories
Product Name
Utah disposable IBP transducer
Brand Name
JCR
Model Number
  JIBPT-01 -UT

Detailed Photos

Main technical parameters and working environment requirements:
Disposable Pressure Transducer
Barometric pressure
70~106Kpa
Relative humidity
10~90% (non-condensing)
Operating pressure range
-50 ~ + 300 mmHg
Sensitivity
5.0μV/V/mmHg ±3%
Nonlinearity and hysteresis
full-scale reading±1.5%
Input impedance
1200Ω ~3200Ω
Zero pressure offset
-20mmHg~+20mmHg
Thermal offset shift
≤±0.3mmHg/°C
Offset drift
After warm-up for 20 seconds, drift within 2 mmHg within 8 hours
Thermal span shift
≤±0.1%/°C
Frequency response
Standard pressure set (48 "/ 12") is 40 Hz; Separate sensor > 200 Hz
Defibrillator withstand
Defibrillation depends on the final connection of the equipment.
Leakage current
Leakage current is dependent on the final connection of the equipment
Overpressure load
-400~+4000mmHg
Shock resistance
Withstand falling from one meter for three times
 
Light sensitivity
When exposed to a 3400°K tungsten light, candle light at 3000 feet, it's less than 1 mmHg under rated voltage.
Storage and transport environment requirements
- 20 ° C~ + 60 ° C, < 90%(non-condensing), no corrosive gas and indoor ventilation, and to avoid high temperature and cold.
Contact with the human body
≤168h
Intra-system velocity
Flow
2-5mL/h
Intra-system velocity refers to the velocity under 6.00 VDC and 25°C, unless there are additional instructions.
Product shelf-life
3 years