JIBPT-01-YP
Surgical Supplies Materials
Ethylene Oxide Sterilization
with Logo Printing
High Polymer Material and Electronic Chips
Three Years
Adult/Chidren
Disposable Pressure Transducer Kit
Medical Materials & Accessories
Hospital, Clinic, ICU Room
CE/ISO13485/TUV
with Flush Device
100PCS/Carton/53*46*45cm
Single /Double/Triple Channel Kit
Compatiable Adapter
to Measure The Pressure of Blood
Yes
JCR
Sterile Blister Box,
Compatible with Abbott Single Channel
Shenzhen, China
9018909991
Product Description
Disposable Pressure Transducer Kit
Disposable Pressure Transducer is used in ICU Anesthesiology and enable to consist and accurate reading of arterial and venous blood pressure measurement.
Available with flushing of 3cc/hr, 30cc/hr or without flush valves.
- Infusion set
- Pressure monitoring line
- Stopcock etc
- Infusion set
- Pressure monitoring line
- Stopcock etc
- Medical disposable









Disposable Pressure Transducer is used in ICU Anesthesiology and enable to consist and accurate reading of arterial and venous blood pressure measurement.
Available with flushing of 3cc/hr, 30cc/hr or without flush valves.
- Infusion set
- Pressure monitoring line
- Stopcock etc
- Infusion set
- Pressure monitoring line
- Stopcock etc
- Medical disposable
Properties | Medical Materials & Accessories |
Product Name | Abbott disposable IBP transducer |
Brand Name | JCR |
Model Number | JIBPT-01-YP |
Main technical parameters and working environment requirements: | ||||
Disposable Pressure Transducer | ||||
Barometric pressure | 70~106Kpa | |||
Relative humidity | 10~90% (non-condensing) | |||
Operating pressure range | -50 ~ + 300 mmHg | |||
Sensitivity | 5.0μV/V/mmHg ±3% | |||
Nonlinearity and hysteresis | full-scale reading±1.5% | |||
Input impedance | 1200Ω ~3200Ω | |||
Zero pressure offset | -20mmHg~+20mmHg | |||
Thermal offset shift | ≤±0.3mmHg/°C | |||
Offset drift | After warm-up for 20 seconds, drift within 2 mmHg within 8 hours | |||
Thermal span shift | ≤±0.1%/°C | |||
Frequency response | Standard pressure set (48 "/ 12") is 40 Hz; Separate sensor > 200 Hz | |||
Defibrillator withstand | Defibrillation depends on the final connection of the equipment. | |||
Leakage current | Leakage current is dependent on the final connection of the equipment | |||
Overpressure load | -400~+4000mmHg | |||
Shock resistance | Withstand falling from one meter for three times | |||
When exposed to a 3400°K tungsten light, candle light at 3000 feet, it's less than 1 mmHg under rated voltage. | ||||
Storage and transport environment requirements | - 20 ° C~ + 60 ° C, < 90%(non-condensing), no corrosive gas and indoor ventilation, and to avoid high temperature and cold. | |||
Contact with the human body | ≤168h | |||
Intra-system velocity | ||||
Flow | 2-5mL/h | |||
Intra-system refers to the velocity under 6.00 VDC and 25°C, unless there are additional instructions. | ||||
Product shelf-life | 3 years |