Diesel Locomotive Cable, DLO Cable
Industrial, Shipyards, Motor Leads, Mining
Low and Medium Voltage Cable
DC & AC
Rubber
CPE, Sunlight Resistant Jacket
Round Wire
Tinned Wire
ISO, CCC, RoHS
Diesel Locomotive Cable, Dlo
Renda
Diesel Locomotive Cable, Dlo Cable
Type Rhh-Rhw-2, Type Dlo Cable
UL2806, UL44
600V, 2000V
Epr, EPDM, Ep
CPE, Sun Resistance, Oil Resistance
Max 90 Degree or 105degre
Yes
Yes
Resists Oils, Acids, Alkalies, Heat
RENDA
Roll, Reel, Coil as Your Requirements
12AWG, 10AWG TO 1111.1Kcmil
China
8544492100
Product Description
DLO Diesel Locomotive Cable
2000V Flexible Tinned Copper Conductor
2000V Flexible Tinned Copper Conductor

DLO is used in a variety of applications by several industries. The extra flexible tinned copper conductor has a suitable separator on sizes 4 AWG and larger. Insulated and jacketed with a crosslinked EPR thermosetting insulation and jacket, Cobra DLO meets the requirements of ICEA S-68-516 providing toughness along with good flexibility. This cable passes the MSHA Flame Test with a continuous rating of 90°C. Cable complies with UL Standards 44 & 1581.
Applications
- Drilling rigs, both on-shore and off-shore
- Railroad and transit cars
- Electric earth-moving equipment
- Shipyard machinery and equipment
- Supply leads for arc welders
- Power and control jumper cable
- Motor leads
STANDARDS & REFERENCES
Type DLO Cable meets or exceeds the applicable requirements of the following standards and
specifications:
RoHS Compliant
MSHA accepted
UL listed as Type RHH-RHW-2 per UL 44
Flexible strand tin coated copper conductor, B-172, ASTM B-33
UL listed as per UL 2806
Meets FT-4 Flame Tests
DLO offers:
90°C temperature rating
Excellent impact and abrasion resistance
Resists oils, acids, alkalies, heat and flame
The flexible tinned copper stranding
CONSTRUCTION
Conductor: Stranded Tinned Copper, Fully Annealed per AAR-598 and ASTM B 33
Insulation: Premium-grade Ethylene Propylene Rubber (EPR)
Cable Jacket: Black Chlorinated Polyethylene (CPE)
Temperature Range: -40°C to +90°C
Voltage Rating: 600 Volts ,1000V,2000V
SIZE AWG Kcmil | CONDUCTOR | POLYESTER FILM | INSULATION | JACKET | NOMINAL OVERALL DIAMETER | WEIGHT | |||||
COND STRAND | Dia. | NOMINAL THICKNESS | NOMINAL INSULATION THICKNESS | NOMINAL JACKET THICKNESS | |||||||
MM | MM | MM | MM | MM | MM | KG/KM | |||||
12 | 1 | × | 37 | / | 0.373 | 2.61 | 0.05 | 1.52 | 0.38 | 6.6 | 86.6 |
10 | 1 | × | 27 | / | 0.47 | 2.81 | 0.05 | 1.52 | 0.38 | 6.8 | 94.6 |
8 | 1 | × | 37 | / | 0.511 | 3.58 | 0.05 | 1.78 | 0.76 | 8.8 | 154.2 |
6 | 1 | × | 61 | / | 0.511 | 4.60 | 0.05 | 1.78 | 0.76 | 9.8 | 213.1 |
4 | 7 | × | 15 | / | 0.511 | 6.53 | 0.05 | 1.78 | 0.76 | 11.8 | 322.2 |
3 | 7 | × | 19 | / | 0.511 | 7.36 | 0.05 | 1.78 | 0.76 | 12.6 | 386.2 |
2 | 7 | × | 23 | / | 0.511 | 8.11 | 0.05 | 1.78 | 0.76 | 13.3 | 449.0 |
1 | 7 | × | 30 | / | 0.511 | 9.27 | 0.05 | 2.29 | 1.14 | 16.3 | 621.3 |
1/0 | 19 | × | 14 | / | 0.511 | 10.50 | 0.05 | 2.29 | 1.14 | 17.5 | 748.5 |
2/0 | 19 | × | 18 | / | 0.511 | 11.93 | 0.05 | 2.29 | 1.14 | 18.9 | 916.7 |
3/0 | 19 | × | 22 | / | 0.511 | 13.21 | 0.05 | 2.29 | 1.14 | 20.2 | 1082.2 |
4/0 | 19 | × | 28 | / | 0.511 | 14.92 | 0.05 | 2.29 | 1.14 | 21.9 | 1326.9 |
262.6 | 19 | × | 34 | / | 0.511 | 16.45 | 0.05 | 2.67 | 1.65 | 25.2 | 1669.4 |
313.3 | 19 | × | 41 | / | 0.511 | 18.08 | 0.05 | 2.67 | 1.65 | 26.9 | 1955.0 |
373.7 | 19 | × | 49 | / | 0.511 | 19.78 | 0.05 | 2.67 | 1.65 | 28.6 | 2277.8 |
444.4 | 19 | × | 58 | / | 0.511 | 21.52 | 0.05 | 2.67 | 1.65 | 30.3 | 2637.5 |
535.3 | 19 | × | 70 | / | 0.511 | 23.65 | 0.05 | 3.05 | 1.65 | 33.2 | 3171.0 |
646.4 | 37 | × | 43 | / | 0.511 | 25.93 | 0.05 | 3.05 | 1.65 | 35.5 | 3715.5 |
777.7 | 37 | × | 52 | / | 0.511 | 28.52 | 0.05 | 3.05 | 1.65 | 38.1 | 4403.1 |
929.9 | 61 | × | 38 | / | 0.511 | 31.32 | 0.05 | 3.05 | 1.65 | 40.9 | 5210.2 |
1111.1 | 61 | × | 45 | / | 0.511 | 34.10 | 0.05 | 3.56 | 2.41 | 46.2 | 6343.0 |

UL Certificate for SOOW CORDS, XHHW,DLO,SEU,MC Cable